HQ Series Instruction Manual
Please read all instructions carefully before installing your new systems, as failures caused by
incorrect installation or operation are not covered by the warranty.
I. Product
The HQ series are designed for the pumping of non-aggressive water, or water not containing solid
particles.
II. Operating conditions:
1. Ambient temp. : Max. +40ºC (104ºF)
2. Liquid temp. : +4ºC(39ºF) ~ +40ºC(104ºF)Max.
3. System pressure: Max. 8.5kg/cm² (121 PSI)
4. Relative humidity: Max. 85%(RH)
5. Indoor Use Only
6. The max head :
III. Installation
1.The pump foundation should be rigid enough to absorb any vibration from the motor, and the
pump should be securely bolted to the foundation.
2. It is recommended that the plumber/installer provides an adequate draining system to avoid
damage in case of leakage, particularly when installed indoors. When it is installed outside, it
should be covered by a weather-proof housing, well ventilated to allow motor heat to escape.
3. Connect the suction pipe to the side and discharge pipe on the top.( See Fig 1 )
4. When it is installed with water heater, a check valve should be installed between pump
(discharge) pipeline and water heater (suction) to avoid high-pressure steam backflow.
5. It is required to shut off the pump when the liquid source is unavailable; although it has the dry
run cut off function.
6. To avoid your furniture damage, do not install the pump on ceiling, carpet or any place close to
electrical appliance, outdoor installation must covered by tent.
7. The electrical connection should be carried out in accordance with local regulations. The
operating voltage and frequency are marked on the nameplate. Please make sure that these data
match with your job requirement. For your safety, be sure the Residual current device (RCD,
30mA) is in your system and grounding is properly connected to prevent from electric shock.
~ 2 ~
60Hz
23m
26m
27m
45m
50Hz
24m
31m
33m
-
Model
HQ200
HQ400
HQ800
HQ800H
Fig. 1
Discharge
Flange Bolt Torque :
20~25 kgf-cm
25
kg-cm
Suction