Wallscapes AALL1045 Installation & Assembly

Page 1
1
EN
External corner solutions wood vertical
If a vertically placed corner solution is prefer red we recommend one row of the wall panel overlap so the side of one for the panels is visible.
Internal corner solutions wood vertical
In case of an internal corner a seamless unbroken row of vertical panels is achieved by
LTL Home Products, Inc
(800) 360-1585
ltlhomeproducts.com
joining corresponding panels using a mitered edge. Connect the return wall using the other half piece from the joining panel.
Disclaimer
Our panels are made entirely of authentic, reclaimed hardwoods from a variety of sources. Wood is a natural material that contains distinctive characteristics in grain colour and texture. Photographs and physical samples should be viewed as illustrative of the collection they represent;in no way should they be regarded as being definitive or of guaranteeing an exact match. Each individual panel is unique. Please note that no returns are offered for product that has been installed. With this in mind we always advise that you take the opportunity to experiment with different panel arrangements prior to final installation.
Your statutory rights are not affected.
Introduction
Congratulations! You have acquired your very own piece from the Wallscapes collection. This means that you are about to enhance your walls with hardwoods that are full of character. Your eye for design will inspire for years to come. Our wall panels have been thoughtfully crafted and designed for all types of interiors. The manual will guide you through the installation process in five simple steps.
Two golden rules
The two golden rules for the best result are:
1 Paint your receiving wall black prior to
installation. 2 Place the wall panels in a random bond. You will find these golden rules clearly marked in bold writing later in this installation manual.
Owner / installer responsibility
All of our panels are thoroughly inspected to ensure that you receive only the very finest specimen hardwoods nature has to bestow. As all of our materials are natural however some natural variations in grading may occur. It is the installer’s responsibility to check the suitability of all panels prior to installation. In the highly unlikely event that any defects are found to be present, you should contact your supplier immediately. Do not install panels you suspect to be defective as we cannot ac-cept returns once panels have been installed.
It is the installer’s responsibility to ensure that the project site is suitable and that the panels are correctly installed (see later). The manufacturer accepts no responsibility for failure due to incorrect or inappropriate installation.
be fully enclosed to the elements and all receiving walls should be completely dry.
The receiving wall
Our wall paneling may be applied to a range of receiving surfaces. For the best results we recommend fixing to an even surface. Flat walls are ideal but by no means vital; a small degree of unevenness is acceptable and will not cause problems.
Condition of receiving wall - general
In general, surfaces should be clean and free from any loose material or debris. They should be completely dry and structurally capable of supporting the aggregate panel weight, together with that of any backing strata (where used). For the best result it is recommended to paint the receiving wall black before mounting.
Tool Check list and accessories needed Tools you will need for the job.
All installations
Broom and/or vacuum, spirit level and/or cross laser level, handsaw, table saw and/or crosscut saw, tape measure, pencil, utility knife, extension cord, ladder and personal protective equipment.
For mounting with adhesive
Silicon gun and elastic MS polymer High Tech.
For mounting with tacker
Tacker, brads 1/20" thickness and 1.2" - 2" depending on the wall panelling type being installed
Project site – Inspection
The Wallscapes collection is suitable solely for 3D Wall or installation. The project site should
Page 2
3
EN
4
EN
Wall panel
Receiving wall
Receiving wall
Wall panel
Wall panel
Wooden
Receiving wall
Wall panel
Anodized aluminium profile
Anodized aluminium profile
Receiving wall
Receiving wall
2
EN
Step 1 Step 3
-
- - - -
-
Step 1: Handling and acclimating your wall Unload and handle panels with care. For best results, we recommend that you store panels in their new environment for a period of one week prior to installing them. Wood is a natural material which reacts to it’s environment, therefore a degree of shrinkage or expansion may be expected depending on the nature of the panels’ new home. Allowing the panels to acclimate in this way prior to installation means that the wood will have significantly stabilized before it is affixed to the wall. A better finish may therefore be achieved. Panels should not be delivered to site unless and until the building is completely closed to the elements.
Step 2 : The first tile
For the most efficient coverage, cut the first tile directly in half, widthwise (with a table saw or a cross-cut saw). Then take one of the half tiles, align the newly created straight edge with the left edge of the wall and fix in place. The other half tile may be used to start subsequent rows as described in step 5.
1 week
Mounting using adhesive
Panels may be mounted to a range of surfaces using the correct fixing medium and in most cases we recommend using a strong elastic MS polymer adhesive High Tech. As a guide, you will require roughly 290 ml adhesive for every 22 sq ft of paneling.
Mounting using tacker
Where panels are to be installed onto a wooden backing surface, a tacker device may be used as an alternative (or in addition) to a polymer adhesive. For best results when using a tacker, take care to ensure that the appearance of the brads is minimized. When affixing wall panels above eye-level, brads should be ‘shot’ at a downwards angle. For panels below eye-level, shoot the brads at an upwards angle. Brads at eye-level should be shot into corners of the panel and between the lats.
3/8"
Step 4 Placing the first rows of your wall
Position the first panels in a straight row along the wall. We recommend using a spirit level or cross laser to mark a straight line on the wall as a guide before positioning the panels. Place the first half panel on the left side of the wall in the manner described in Step 2 and follow the spirit line. With this golden rule #2 a random bond is created which makes the joints disappear. Continue with the other panels until you reach the end of the row, using a table saw or a cross-cut saw to cut the final panel to size. The leftover piece of panel may be used to start the second row. For best results, we recommend an irregular panel formation; that is to say that you do not exactly repeat the formation of the panels in successive rows. After installation of the first 5 rows check that straight lines have been maintained, correc ting if necessary.
Step 5
3/8"
3/8"
Mounting your wall
Place the panels in an irregular (mixed) formation and work first upwardly in rows until you come to the top of the wall. In each row, the leftover portion of panel from the end of one row may be used as the starting panel for the following row. Remember that this is subject to it’s suitability to maintain the overall irregu-lar formation; where it is not suitable, cutting to an alternative size should make it so. We advise leaving a 3/8" expansion space both below and atop of the wall.
LARGE SURFACE AREAS
Expansion joints in building structure
For both mounting using adhesives or using a tacker in projects with large surface areas it is always advised to accommodate the expansion joints in the building structure by allowing the same expansion space in the wall paneling. This space may be filled with a flexible sealant.
Layout and expansion space
When the wall paneling area exceeds 33 ft in width and/or 100 ft in length, additional expansion space must be incorporated into the field, as well as at the perimeter and all obstructions.
Special solutions power sockets and light switches
Light switches and power sockets can be integrated by cutting a hole within the panel. Always measure carefully before cutting the hole.
Internal corner solutions wood
In case of an internal corner a seamless unbroken row of panels is achieved by joining corresponding panels using a mitered edge. Connect the return wall using the leftover piece from the joining panel.
External corner solutions wood
A seamless corner/unbroken row of panels is achieved by joining corresponding panels using a mitered edge. Connect the return wall using the leftover piece from the joining panel.
External corner solutions wood
molding
Using a square wooden molding will delineate joining walls and put a strong emphasis on the corner itself. We recommend that you use a well matched wood type for this solution.
External corner solutions metal
If a narrower, corner-defining solution is preferred we recommend using an anodised or powder coated aluminium profile of 3/16" thickness, positioned within the miter joint.
External corner solutions metal
Wall panel
For this open corner solution we recommend using an anodised or powder coated alumini­um profile of 2" x 2".
Loading...