Figure 11:
Table 1:
- Inclusion of a solenoid valve in the fuel hose near the
tank is necessary if the tank’s fuel level is above the
oven’s or stove’s bottom.
- If the fuel tank is more than 0.5 m above or 1.5 m
below the oven or stove, check the fuel feed and
make any necessary adjustments in accordance
with the separate instructions.
- The fuel hose must always have a fuel filter .
- In the combined unit there is a T -connector for fuel
hoses. The common fuel hose of the oven and stove
is connected into the branch downwards so the play
can be turned under the oven.
- The fuel hose joints must be fully tightened!
Check the joining surfaces for dirt before
tightening.
Electrical Connection
Important:
- During start-up, the appliance uses approx. 8 amps
of current for 2.5 – 6 minutes.
- A 15 amp fuse must be mounted close to the battery .
- T ake the appliance’s power directly from the battery
terminals, not the fuse box or distributing box, to
minimise voltage loss.
- The cables must be protected if there is a risk of
mechanical damage.
- T able 1 shows the minimum diameter of the cables.
- Connect the electric cable’s red lead to the plus (+)
terminal and the black lead to the minus (-) terminal.
- The cables are protected by rubber rings. In the
protection balk down back there are fixing points
for both oven and stove cables. Care must be taken
that the wires don´t come into contact with the
exhaust. Turn the play under the oven.
Figure 12: Oven connection.
Connector for the oven control panel
Solenoid valve
Power cable
Fuel hose
Solenoid valve with 97D oven-stove unit
Installing the Lead-Through
Installation Considerations
- The exhaust pipe should be bent into the shape of a
gooseneck to prevent water from splashing into the
unit.
- The exhaust pipe must be insulated a bendable metal
pipe that is larger in diameter than the normal
exhaust pipe.
- The Insulation pipe is connected to the fresh air duct
of combination lead-through.
- In a metal-hulled boat it is recommended to insulate
the lead-through to prevent electro-chemical
corrosion.
- There is an separate instruction for lead-throughs.
Connecting the Fuel System to the
Boat’s Main Tank
If solenoid valve must be installed to the fuel system,
it must open when one or both appliances are used.
97D oven-stove unit has in build a relay pcb. Install
solenoid valve wires to connection C2. Solenoid valve
uses always two wires; these wires are included in
the solenoid valve kit 30012.