5 Year Limited Warranty ....................................43
1 2
IMPORTANT PRODUCT NOTICES AND
SAFETY INSTRUCTIONS
When using your blood pressure monitor, basic precautions should
always be followed. Please read and follow all instructions and
warnings before using this product. Save these instructions for future
reference.
• Please note that this is a home healthcare product only and it is
not intended to serve as a substitute for the advice of a physician
or medical professional.
• This device uses the oscillometric method to measure systolic
and diastolic blood pressure, as well as heart rate.
• Do not use this device for diagnosis or treatment of any health
problem or disease. Measurement results are for reference only.
Consult a healthcare professional for interpretation of pressure
measurements. Contact your physician if you have or suspect any
medical problem. Do not change your medications without the
advice of your physician or healthcare professional.
• Proper cuff size is critical for accurate measurements. Follow the
instructions in this manual and printed on the arm cuff to ensure
the arm cuff is used properly.
• This product is not suitable for people with arrhythmias. This device
may have difficulty determining the proper blood pressure for
pregnant women and for users with irregular heartbeat, diabetes,
poor circulation of blood, kidney problems or for users who have
suffered from a stroke.
• Excessive use may result in blood overflow interference,
which is likely to cause uncomfortable sensations, such as
partial subcutaneous hemorrhage, or temporary numbness to
your arm. In general, these symptoms should not last long.
However, if you do not recover in time, please seek advice from
a medical professional.
• The pulse display is not suitable for checking the frequency of
heart pacemakers.
• Electromagnetic interference: The device contains sensitive
electronic components. Avoid strong electrical or electromagnetic
fields in the direct vicinity of the device (e.g. mobile telephones,
microwave ovens). These may lead to temporary impairment of
measurement accuracy.
• Consider the electromagnetic compatibility of the device
(ex. power disturbance, radio frequency interference etc.)
Please use this device indoors only.
• Use blood pressure monitor only for its intended use.
• Do not wrap the cuff around body parts other than your arm.
• Not for use by or on persons under the age of 18.
• Do not use this device on infants, children, or those who cannot
express their own intention.
• Do not plug or unplug the adapter power cord with wet hands.
• Please use only the AC adapter included with this monitor or 1.5V
“AA” alkaline batteries for power supply.
Blood pressure measurements determined with this device are
equivalent to those obtained by a trained observer using the cuff/
stethoscope auscultatory method, within the accuracy limits
prescribed by the American National Standard, Manual, electronic, or
automated sphygmomanometers.
3 4
ABOUT BLOOD PRESSURE
What is Blood Pressure?
Blood pressure is the pressure exerted on the artery walls while blood
flows through the arteries. The pressure measured when the heart
contracts and sends blood out of the heart is systolic (highest) blood
pressure. The pressure measured when the heart dilates with blood
flowing back into the heart is called diastolic (lowest) blood pressure.
Why Measure Your Blood Pressure?
Among today’s various health problems, those associated with high
blood pressure are very common. High blood pressure dangerously
correlates with cardiovascular diseases. Therefore, blood pressure
monitoring is important for identifying those at risk.
Why Do My Readings Vary?
Blood pressure is a body parameter that is subject to normal
variations throughout the day. A single reading that is different from
yours or your doctor’s readings are not necessarily inaccurate. The
average of several readings, taken under similar conditions, using the
same arm is preferred for accurate blood pressure readings.
Why Are My Readings Different Than Those Taken at My
Doctor’s Office?
Many experience a phenomenon called “White Coat Hypertension”
when measured by a doctor. White Coat Hypertension refers to blood
pressure that rises above its usual level when measured in a clinical
setting, such as a doctor’s office.
BLOOD PRESSURE STANDARD
The table on page 6 contains defined levels for hypertension that
are publicly available from the National Heart Lung and Blood Institute
at the U.S. National Institutes of Health (NIH)
(http://www.nhlbi.nih.gov/health/dci/Diseases/Hbp/HBP_WhatIs.html).
5 6
Users can compare their own blood pressure readings against these
defined levels to determine if they may be potentially at
increased risk.
This table is applicable to most adults aged 18 and older.
Category
NormalLess than 120andLess than 80
Prehypertension120-139or80-89
High Blood Pressure
Stage 1140-159 or90-99
Stage 2160 or higheror100 or higher
Blood pressure tends to go up and down, even in people who
normally don’t have high readings. If your numbers stay above the
“normal” range most of the time, you may be at increased risk and
should consult your physician.
Although one can easily find where their own blood pressure
readings fall on this table, this monitor comes equipped with a Risk
Category Index that automatically compares each reading to the
defined levels and provides a helpful cue if your reading falls into
one of the stages that could potentially indicate increased risk. See
page 29 for more information on this feature.
Please note that cues provided by this monitor are only intended to
assist you in using this table. The table and cues are only provided
for convenience to help you understand your non-invasive blood
pressure reading as it relates to the NIH information. They are
not a substitute for a medical examination by your physician. It is
important for you to consult with your physician regularly. Your
physician will tell you your normal blood pressure range as well as
the point at which you may actually be considered to be at risk.
Systolic (mmHg)
Diastolic
(mmHg)
HOW THIS BLOOD PRESSURE MONITOR WORKS
This monitor uses innovative GentleInflate™ technology to detect
your blood pressure. With one touch of a button, the monitor
automatically takes the reading during inflation, then deflates,
delivering a quick, comfortable and quiet measurement every time.
Please note that any muscle movement during inflation will cause
measurement error. When measurement is complete, the monitor
will display your systolic pressure, diastolic pressure, and pulse
readings.
NAME/FUNCTION OF EACH PART
Air Tube
and Connector
ONONOFFOFF
Triple CheckRest Assure
1
1. Triple-Check Switch
2. Rest Assure Switch
2
Before measurement, it is suggested that you sit quietly for 15
minutes before measurement as measurements taken in a relaxed
state have greater accuracy. The Rest Assure Function provides
a helpful countdown of the last 5 minutes of this suggested time*.
Refer to page 16 for more information on this feature.
The Triple-Check (Multi-Read) Function automatically takes and
averages three readings for accuracy you can trust. Refer to page
16 for more information on this feature.
The monitor automatically finds where your measurement results
fall on the NIH’s National Heart Lung and Blood Institute’s table
and provides a cue if your reading falls into one of the stages that
could potentially indicate increased risk. Please refer to page 29
for more information on this feature.
The appearance of the icon indicates that a pulse irregularity
consistent with an irregular heartbeat was detected during
measurement. Refer to page 30 for more information on the Irregular
Heartbeat Detector.
*JNC7: The Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and
Treatment of High Blood Pressure. NIG Publication No. 04-5230 August 2004.
7 8
UltraSoft™ Upper
Arm Cuff
MEMORY RECALL
Button
Other Accessories Included :
USER-SELECT
Button
• 1 6V DC Output AC Adapter
• 4 “AA” size, 1.5V alkaline batteries
Note: Please remove the batteries when operating
with the AC adapter for an extended period of
time.
START/STOP
Button
LCD Display
AM/PM Averaging
Button
Date/Time Set
Button
Battery Cover
(Located on
bottom of unit)
BLUETOOTH
Button
®
DISPLAY EXPLANATIONS
HL858CB ( Bluetooth)LCD View Area: 74mm x 95 mmDigital Size:43.5mm
3
HL858CB ( Bluetooth)LCD View Area: 74mm x 95 mmDigital Size:43.5mm
Date/Time
Indicator
Heart Rate
Systolic
Pressure
Diastolic
Pressure
Display Symbols:
User 1: Appears when the monitor is operated by User 1.
User 2: Appears when the monitor is operated by User 2.
Weak Battery Symbol: Appears when batteries should be replaced.
Pulse Symbol: Shows the heart rate per minute.
Risk Category Index: See page 29 for more information.
Irregular Heartbeat Detector: See page 30 for more information.
Data Transmitting Symbol: Appears when data is transmitting to your
mobile device.
• Rest Assure ON: The REST symbol will appear on monitor, then will countdown
for 5 minutes before starting single measurement.
• Triple-Check FunctionON: The REST symbol will flash among 3
measurements during countdown.
Memory Average: Displays average of last 3 readings.
AM/PM Averaging: Indicates the reading being displayed is an average from
the last 3 morning or last 3 evening measurements.
If and any of the following letters and numbers appear in the area
that systolic pressure should be displayed, an error has occurred with your
reading. See Troubleshooting section of this manual for more information.
Multi-Read Symbol: Appears when Triple-Check (Multi-Read) Function is
turned ON.
Average Symbol: Displayed when viewing a Triple-Check average.
Measurement Indicator: Indicates which measurement is being taken, or
which measurement is being viewed from a Triple-Check average reading.
Measurement Error: Wrap the cuff correctly and keep arm steady during
measurement. Take new measurement.
Air Circuit Abnormality: Check cuff connection. Take new measurement.
Pressure Exceeding 300 mmHg: Turn the unit off to clear, then
take new measurement.
Error Determining Measurement Data: Take new measurement.
Data Transmission Error: Monitor cannot connect to the mobile device to
transmit data. Make sure Bluetooth is ON.
System Error: Take new measurement.
9 10
INSTALLING BATTERIES
1. Press foward on latch and lift
the battery cover to open the
battery compartment.
2. Install or replace 4 “AA ” sized
alkaline batteries in the battery
compartment according to
the indications inside the
compartment.
3. Close the battery cover by
pushing in the top end of the
battery door.
Replace the batteries if:
• The weak battery symbol appears.
• When any button is pressed and nothing is displayed on
the screen.
Note:
• If the batteries are removed or replaced, the date and time will
need to be re-set either manually or automatically using your
Bluetooth mobile device.
• Replace all batteries at one time (as simultaneous set). Use
only 1.5V “AA” alkaline batteries.
• When the batteries are removed, the measurement values are
retained.
• Remove batteries when unit is not in use for extended periods of
time.
• Clean contacts on battery and in battery compartment with a soft
dry cloth each time you install batteries.
• Batteries are hazardous waste. Do not dispose of them
together with the household garbage.
11 12
Battery
Cover
USING THE AC ADAPTER
1. Connect the AC adapter with the AC adapter jack as shown
below.
2. Please use only the AC adapter included with this monitor.
Note:
• When the AC adapter is your main power supply, make sure
the adapter plug can be easily removed from the unit.
• Please unload the batteries when operating with an AC
adapter for an extended period of time. Leaving the batteries
in the compartment for a long time may cause leakage,
which may lead to damage to the unit.
• No batteries are needed when operating with an AC
adapter.
• Date and time will need to be reset if AC adapter is
unplugged and unit is without batteries.
ONONOFFOFF
Triple CheckRest Assure
Connect AC
adapter here
AC Adapter
Input: 100-240V~0.18A-0.20A 50/60Hz
Output: 6V DC 1A 6W Max
DATE & TIME SET PROCEDURE
Date & time can be set by two methods, either sync
automatically using your Bluetooth mobile device, or set
manually using the SET buttons on the monitor ( +).
To Set Manually:
1. To set the date and time, press
the DATE/TIME SETbutton
.
AM/PM
If setting the date & time by syncing with your mobile device, it
is important that this is done prior to taking any measurements
to ensure the date & time are accurate.
To set using your device with Bluetooth wireless
technology:
®
1. Before taking the first measurement, open the Walgreens
Connect App on your device. If you have not already installed
the Walgreens Connect App onto your device, it is available
to download on the App Store
SM
and on Google Play
TM
. Make
sure you have the app downloaded and open on your mobile
device before trying to sync the date & time.
2. Press the Bluetooth button on the monitor
to enable the connection.
3. Once the Bluetooth connection is established,
the date & time will automatically update on the
blood pressure monitor.
Note:
• Once the date & time have been successfully synced, future
readings will automatically have the correct date & time.
2. The display will show a blinking number showing the
MONTH. Change the MONTH by pressing the + button.
Each press will increase the number by one in a cycling
manner. Press the DATE/TIME SET button
again to
confirm the entry, and the screen will show a blinking number
representing the DAY.
3. Change the DAY, YEAR, HOUR and MINUTE as described in
Step 2 above, using the + button to change the numbers
and the DATE/TIME SET button
+
repeat process to set DAY, YEAR,
HOUR and MINUTE
to confirm the entries.
Press the button
blinking MONTH
increasing MONTH
confirm the entry
• If you are having trouble automatically syncing the date &
time, make sure the Bluetooth is ON on your device and ON
on the blood pressure monitor.
13 14
BLUETOOTH
®
OPERATION
This monitor has Bluetooth function ON for your convenience.
This will allow your readings to automatically transmit to the
Walgreens ConnectApp. By turning this function OFF, the
measurements cannot be transmitted.
Turning Bluetooth® Function OFF:
While the screen is off (nothing is shown
on the screen), press and hold the
Bluetooth button for 3 seconds to
turn Bluetooth OFF.
Bluetooth Function OFF
• When Bluetooth® is OFF, measurements cannot be
transmitted to the Walgreens ConnectApp.
Turning Bluetooth® Function ON:
While the screen is off (nothing is shown
on the screen), press and hold the
Bluetooth button for 3 seconds to
turn Bluetooth® ON.
Bluetooth Function ON
• When Bluetooth is ON, readings can automatically and
manually be trasnmistted to the App.
• The Walgreens ConnectApp must be open on your mobile
device in order to establish a connection with the monitor.
USING REST ASSURE FUNCTION
This blood pressure monitor features the Rest Assure Function. It
is suggested you sit quietly for 15 minutes prior to measurement.
The Rest Assure Function will count down the last 5 minutes
before automatically starting the measurement*. To turn this
feature OFF, slide the switch on the back to the OFF position.
ONONOFFOFF
Triple CheckRest Assure
USING TRIPLE-CHECK (MULTI-READ) FUNCTION
The Triple-Check (Multi-Read) Function automatically takes and
averages three readings in a row, with 1 minute rest intervals in
between each measurement. To deactivate this feature and take
only a single reading, slide the switch on the back to the OFF
position.
ONONOFFOFF
Triple CheckRest Assure
Bluetooth QDID Profile Information:
QDID: 45008, 51582, & 52727
*JNC7: The Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of
High Blood Pressure. NIG Publication No. 04-5230 August 2004.
15 16
USING THE ULTRASOFT™ UPPER ARM CUFF
BLUE
Very Important:
Proper cuff size is critical to accurate measurement.
This monitor comes with one UltraSoft™ Upper Arm Cuff that
fits arm sizes 9”-17” (23cm - 43cm).
The appropriate cuff is suitable for your use if the colored
arrow falls within the solid color line as shown below.
Colored Arrow
1. If the cuff is not assembled, pass the end of the cuff furthest
away from the tubing through the metal D-ring in order to form
a loop. The smooth side without the felt material should be on
the inside of the cuff loop.
End of cuff
D-ring
ARROW MUST FALL
WITHIN BLUE BAND
ARROW MUST FALL
BLUE
WITHIN BLUE BAND
2. Plug the cuff tube into the left side of the unit.
Insert connector here
Solid Colored Line
17 18
ARROW MUST FALL
WITHIN BLUE BAND
3. Open the arm cuff so that your arm may be
placed through it.
4. Remove tight fitting clothing from your upper
left arm so that the cuff can be wrapped
around your exposed arm.
• This device should not be used when your arm is injured
or wounded.
• If it is not possible to fit the cuff on your left arm, it
can also be placed on your right arm. However, all
measurements should be made using the same arm.
• To use on the right arm, you must position the artery
symbol “ ” over the main artery. Locate the main
artery by pressing with two fingers approximately 1”
(2 cm) above the bend of your elbow on the inside of
your right arm. Identify where the pulse can be felt the
strongest. This is your main artery.
6. Center tube over middle of arm.
7. Pull the end of the cuff so that it tightens
evenly around your arm. Press the hook
and loop material together to secure.
Allow room for 2 fingers to fit between the
cuff and your arm.
8. Lay your arm on a table (palm upward) so
the cuff is at the same height as your heart.
Make sure the tube is not kinked.
19 20
Main Artery
MEASUREMENT PROCEDURE
Important Notes:
• Blood pressure changes with every heartbeat and is in constant
fluctuation throughout the day.
• Blood pressure measurement can be affected by the position
of the user, his or her physiologic condition and other factors.
Before Measurement:
To help ensure an accurate reading, follow these instructions
before taking a measurement:
• Wait 1 hour after exercising, bathing, eating, drinking
beverages with alcohol or caffeine, or smoking to measure
blood pressure.
• Take your reading in a comfortable enviroment as
measurements can be affected by hot or cold temperatures.
Take your blood pressure at normal body temperature.
During Measurement:
• Do not talk or move your arm or hand muscles.
• Do not cross your legs. Sit with feet flat on the floor.
• Do not touch cuff or monitor during measurement.
Using Single Measurement Mode:
1. Please make sure the Triple-Check switch, located on the
back of the unit, is in the OFF position.
2. Press the USER-SELECT button to choose User 1 or User 2.
M
After the user number is selected, press the START/STOP
button to confirm the chosen user.
3. With the cuff wrapped around your arm, press the START/
STOP button. Do not inflate the cuff unless it is wrapped
around your arm. All digits will light up to check the display
functions. The checking procedure will be completed after
about 3 seconds.
START
STOP
If you are using this blood pressure monitor for the first
time, please remove the protective film from the screen.
21 22
Note:
If the Rest Assure Function is ON, the 5 minute countdown will
begin after the checking procedure is complete.
4. After all symbols disappear, the display will show “00”. The
Rest Assure
ONAM/PM
OFF
monitor is “Ready to Measure” and will automatically inflate
the cuff to begin measurement.
Using Triple-Check Measurement:
1. Please make sure the Triple-Check switch, located on the
back of the unit, is in the ON position.
5. When the measurement is completed, the cuff will deflate
entirely. Systolic pressure, diastolic pressure and pulse
will be shown simultaneously on the LCD screen. The
measurement is then automatically stored into memory.
Note:
• This monitor automatically returns to
standby mode approximately 60 seconds
after last operation. You may also press the
START/STOP button to return to standby
mode.
• To interrupt the measurement, you may
press the START/ STOP button. The cuff
will deflate immediately after a button is pressed.
ON
OFF
Triple Check
2. Press the USER-SELECT button. After the user number
is selected, press the START/STOP button to confirm the
chosen user.
3. With the cuff wrapped around your arm, press the START/
STOP button. Do not inflate the cuff unless it is wrapped
around your arm. All digits will light up to check the display
functions. The checking procedure will be completed after
about 3 seconds.
Note:
If the Rest Assure feature is ON, the 5 minute countdown will
begin after checking procedure is complete.
4. After all symbols disappear, the display will show “00”. The
monitor is “Ready to Measure” and will automatically inflate
the cuff to begin measurement.
23 24
5. When the measurement is completed, the cuff will deflate
HL858CB ( Bluetooth)LCD View Area: 74mm x 95 mmDigital Size:43.5mm
entirely. Once the cuff is fully deflated, a 1 minute countdown
will begin before starting the second measurement
automatically. This process will continue until the end of
the third measurement.
Note:
• If an ERROR code is displayed during measurement, the
monitor will repeat the measurement up to 3 times during the
consecutive measurement process.
• Remain still until all 3 measurements are completed.
TRANSMIT READINGS TO YOUR MOBILE DEVICE
This monitor syncs your blood pressure readings
to the Walgreens ConnectApp that is free to
download on the App StoreSM and on
Google Play™. Make sure you have the
Walgreens ConnectApp downloaded, and open
on your mobile device before trying to transmit
your blood pressure measurements.
Before attempting to sync the blood pressure monitor with
your mobile device, make sure Bluetooth is turned ON, on both
your mobile device and the monitor.
6. At the conclusion of the third measurement, the Triple-Check
average will be displayed.
To review your individual results that make the Triple-Check
average, press the + button.
press the
+ button
25 26
Automatically transmit readings:
After a measurement is taken, the Bluetooth icon will appear
on the screen as the monitor automatically transmits your
blood pressure readings to the App.
Manually transmit readings:
Press the Bluetooth button . The readings
will automatically be transmitted to the App. The
Bluetooth icon will appear on the screen as the
Fig. 1
monitor transmits your blood pressure
readings to the App.
If the transmission(s) were successful,
the Bluetooth icon will be displayed
on the screen. See Fig. 1.
Loading...