Waldorf RN8910G, RNL8910G, RNB8910G, RNLB8910G Installation And Operation Manual

1
Installation and Operation Manual
Series
RN8910G RNL8910G RNB8910G RNLB8910G
Gas Range Static Oven
Date Purchased
Dealer
Service Provider
232779-8
For use in GB & IE
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless auth orized previously in writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
© Copyright Moffat Ltd. November 2014.
MANUFACTURED BY
Moffat Limited
Rolleston 7675 New Zealand
INTERNATIONAL CONTACTS
AUSTRALIA
Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3833
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk E.Mail: sales@blue-seal.co.uk Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711 Spares: (tel): +44 121 322 6640 (fax): +44 121 327 9201 Service: (tel): +44 121 322 6644 (fax): +44 121 327 6257
UNITED STATES
Moffat Web: www.moffat.com Sales: (tel): 800 551 8795 (Toll Free)
(tel): +1 336 661 1556 (fax): +1 336 661 9546 Service: (tel): 800 858 4477 (Toll Free) (tel): +1 336 661 1556 (fax): +1 336 661 1660
REST OF WORLD
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
Contents List
Waldorf Gas Range Static Oven
RN(L)(B)8910G Gas Range Static Oven - 4 Burner, 900mm Wide.
Introduction .............................................................................................. 2
Specification .............................................................................................. 3
Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection
Dimensions ................................................................................................ 6
Installation ................................................................................................ 7
Installation Requirements Unpacking Location Clearances Assembly Gas Connection Commissioning
Operation ................................................................................................. 10
Operation Guide Description of Controls Open Burners Lighting the Oven Pilot Burner Lighting the Oven Main Burner Turning the Oven to ‘Stand-By’ (Pilot ‘ON’ Only) Oven ‘Shut Down’
Cleaning and Maintenance ...................................................................... 14
Before Commencing Cleaning Open Burner Cleaning Oven Interior Cleaning Stainless Steel Surfaces
Fault Finding ............................................................................................ 16
Gas Conversion and Specifications ......................................................... 17
Conversion Procedure Gas Specifications
Replacement Parts List ............................................................................ 22
2
Introduction
We are confident that you will be delighted with your WALDORF GAS RANGE STATIC OVEN and it will become a most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Waldorf appliance, there are two important things you can do.
Firstly:
Please read the instruction book carefully and follow the directions given. The time taken will be well spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance, contact your WALDORF dealer promptly. In many cases a phone call could answer your question.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for adapting the appliance to the conditions for use in that country.
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF
FIRE.
 T
HE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
 I
T IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO
ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
 DO NOT
STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
Warning

This appliance is for professional use and is only to be used by qualified persons.

Only authorised service persons are to carry out installation, servicing or gas conversion operations.

Components having adjustments protected (e.g. paint sealed) by the manufacturer should not be adjusted by the user / operator.

DO NOT operate the appliance without the legs supplied fitted.
Caution
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CA N CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
Warning
INSTRUCTIONS
TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
Warning
3
Specifications
Model Numbers Covered in this Specification
RN[1]8910G-[2] Gas Static Oven + 4 Open Burners.
NOTE:
[1]: - Model Options;
- - Standard Models. L - Low Back Models. B - Bold Front. LB - Low Back and Bold Front.
[2] - Open Burner Options;
F - With Flame Failure Protection. PF - With Pilot and Flame Failure Protection.
General
A heavy duty, general purpose gas range created for compact modular kitchens. It is available on industrial adjustable feet or on robust rollers.
Open Burners are available in either 'PF' (Pilot and Flame Failure) or 'F' (Flame Failure Only) options. Open Burners are fitted with individual flame failure for each open burner. Oven is fitted with pilot and flame failure with piezo ignition.
Easy clean stainless steel external finish.
4
Specifications
Gas Supply Requirements
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P
(20, 37).
Flue Type: A1.
* Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set through the appliance regulator and is not to be adjusted, apart from when carrying out gas conversion, if required. (Refer to ‘Gas Conversion’ section for details).
Natural Gas (G20) Propane (G31)
Open Burner
(each)
Oven Open Burner
(each)
Oven
Heat Input (nett)
Nominal
6.5 kW 7.8 kW 6.5 kW 7.8 kW
Reduced
1.75 kW --- 1.75 kW ---
Gas Rate (nett)
Nominal
0.69 m3/hr 0.83 m3/hr 0.51 kg/hr 0.61 kg/hr
Reduced
0.19 m3/hr --- 0.14 kg/hr ---
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure (*)
9.5 mbar 26 mbar
Gas Connection
3
/4” B.S.P. Male
Natural Gas LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- Oven 30 MJ/hr 30 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa Burner Operating Pressure (*) 0.95 kPa 2.6 kPa Gas Connection
3
/4” B.S.P. Male
Natural Gas LP Gas
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- Oven 30 MJ/hr 30 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa Burner Operating Pressure (*) 0.95 kPa 2.6 kPa Gas Connection
3
/4” B.S.P. Male
5
Specifications
- All Other Markets:
NOTE:
 (*) Measure Burner operating pressure at manifold test point with 2 burners operating at
'High Flame' setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
 (**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
 Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand side, 32mm from rear and 655mm from floor and is reached from beneath appliance. (Refer to ‘Dimensions’ section).
Connection is ¾" BSP male thread.
Electrical Supply Requirements
230-240 V a.c, 50 Hz, 1.6A, 1P+N+E.
0.4kW. Oven Fan Motor - 100W.
Natural Gas Town Gas (**)
Input Rate (N.H.G.C.)
- each Open Burner
28MJ/hr 28MJ/hr
- Oven 30 MJ/hr 30 MJ/hr
Supply Pressure 1.13 - 3.40kPa 0.75 - 1.50kPa Burner Operating Pressure (*) 0.95kPa 0.63 Pa Gas Connection See ‘Gas Connection’ information overleaf
LP Gas (Propane) Butane
Input Rate (N.H.G.C.)
- each Open Burner
28MJ/hr 28MJ/hr
- Oven 30 MJ/hr 30 MJ/hr
Supply Pressure 2.75 - 4.50kPa 2.75 - 4.50kPa Burner Operating Pressure (*) 2.6kPa 2.6kPa Gas Connection See ‘Gas Connection’ information overleaf
6
Dimensions
RN
(L)
8910G
Loading...