Waldorf RN8900G, RNL8450G, RNL8900G Installation And Operation Manual

Installation and Operation Manual
Gas Cooktops
Series RN8450G RNL8450G
RN8900G RNL8900G
Date Purchased
Serial Number
Service Provider
232778-5
For use in GB & IE
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
© Copyright Moffat Ltd. November 2011.
MANUFACTURED BY
Moffat Limited
Christchurch New Zealand
INTERNATIONAL CONTACTS
AUSTRALIA
Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3833
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk E.Mail: sales@blue-seal.co.uk Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711 Spares: (tel): +44 121 322 6640 (fax): +44 121 327 9201 Service: (tel): +44 121 322 6644 (fax): +44 121 327 6257
UNITED STATES
Moffat Web: www.moffat.com Sales: (tel): 800 551 8795 (Toll Free)
(tel): +1 336 661 1556 (fax): +1 336 661 9546 Service: (tel): 800 858 4477 (Toll Free) (tel): +1 336 661 1556 (fax): +1 336 661 1660
REST OF WORLD
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
Contents List
Waldorf Gas Cooktops
RN[L]8450G Gas Cooktop 450 mm wide. RN[L]8900G Gas Cooktop 900 mm wide.
Introduction .............................................................................................. 2
Specification .............................................................................................. 3
Model Numbers Covered in this Specification
General
Gas Supply Requirements
Gas Connection
Dimensions ................................................................................................ 5
Installation ................................................................................................ 9
Installation Requirements
Unpacking
Location
Clearances
Assembly
Fitting Adjustable Feet / Rear Rollers to Leg Stand Units
Fitting Adjustable Feet / Rear Rollers to Cabinet and Refrigeration Bases
Gas Connection
Commissioning
Operation ................................................................................................. 15
Operation Guide
Description of Controls
Open Burners
Cleaning and Maintenance ...................................................................... 17
General
After Each Use
Daily Cleaning
Weekly Cleaning
Periodic Maintenance
Fault Finding ............................................................................................ 21
Gas Conversion and Specifications.......................................................... 22
Conversion Procedure
Gas Specifications
Replacement Parts .................................................................................. 24
2
Introduction
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF
FIRE.
 T
HE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
 I
T IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO
ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
 DO NOT
STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
Warning

This appliance is for professional use and is only to be used by qualified persons.

Only authorised service persons are to carry out installation, servicing or gas conversion operations.

Components having adjustments protected (e.g. paint sealed) by the manufacturer should not be adjusted by the user / operator.

DO NOT operate the appliance without the legs supplied fitted.
Caution
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
Warning
INSTRUCTIONS
TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
Warning
We are confident that you will be delighted with your WALDORF GAS COOKTOPS, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Waldorf Gas Cooktops, there are two important things you can do.
Firstly:
Please read the instruction book carefully and follow the directions given. The time taken will be well spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance, contact your WALDORF dealer promptly. In many cases a phone call could answer your question.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for adapting the appliance to the conditions for use in that country.
3
Specifications
Model Numbers Covered in this Specification
RN[1]8450G [2]-[3] 2 Open Burners. RN[1]8900G [2]-[3] 4 Open Burners.
NOTE:
[1] - Back Options;
- - Standard Models. L - Low Back Models.
[2] - Open Burner Options;
F - With Flame Failure Protection. PF - With Pilot and Flame Failure Protection.
[3] - Base Stand Options;
B - Bench Top. CB - Cabinet Base. LS - Leg Stand . RB - Refrigerated Base (RN8940G model only).
General
A heavy duty, high efficiency open burners Cooktops for modular kitchens. It is available either on industrial adjustable feet or on robust rollers with various models of base stand available. Fitted with either 'Individual Flame Failure' (F) or 'Pilot and Flame Failure' (PF) option for each open burner. Easy clean stainless steel external finish.
4
Specifications
Gas Supply Requirements
- Non CE Only (Australia / New Zealand):
- CE Only:
Appliance Classification
Category: II
2H3P.
Flue Type: A1.
* Measure burner operating pressure at manifold test point with 2 burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’ section for details).
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand side, 32mm from rear, 655mm from floor and is reached from beneath appliance. (Refer to ‘Dimensions’ section).
Connection is ¾" BSP male thread.
Natural Gas (G20) Propane (G31)
Open Burner
(each)
Open Burner
(each)
Heat Input (nett)
Nominal 6.5 kW 6.5 kW Reduced 1.75 kW 1.75 kW
Gas Rate (nett)
Nominal 0.69 m3/hr 0.51 kg/hr Reduced 0.19 m3/hr
Supply Pressure 20 mbar 37 mbar
Burner Operating Pressure 9.5 mbar (*) 26 mbar (*)
Gas Connection See ‘Gas Connection’ information overleaf
0.14 kg/hr
Natural Gas LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
(26,540 Btu/hr)
Supply Pressure
1.13 - 3.40 kPa
(4.5” -13.5” w.c.)
2.75 - 4.50 kPa (11” -18”w.c.)
Burner Operating Pressure
0.95 kPa (*) (3.7” w.c.)
2.6 kPa (*)
(10.0” w.c.)
Gas Connection See ‘Gas Connection’ information overleaf
28 MJ/hr
(26,540 Btu/hr)
5
Dimensions
Bench Top Models
RN[L]8450G-B
RN[L]8900G-B
6
Dimensions
Cabinet Base Models
RN[L]8450G-CB
RN[L]8900G-CB
= Rating Plate Location for
this option.
R
R
7
Dimensions
Leg Stand Models
RN[L]8450G-LS
RN[L]8900G-LS
= Rating Plate Location for
this option.
R
R
Loading...
+ 19 hidden pages