Waldorf RN8510G Series, RNL8610G Series, RN8810G Series, RNL8510G Series, RNL8810G Series Installation And Operation Manual

...
1
Installation and Operation Manual
Series RN8510G RN8610G RN8810G
Gas Range Static Oven
Date Purchased
Dealer
Service Provider
228681-13
RNL8510G RNL8610G RNL8810G
For use in GB, IE & DK
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless auth orized previously in writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
© Copyright Moffat Ltd. November 2011.
MANUFACTURED BY
Moffat Limited
Christchurch New Zealand
INTERNATIONAL CONTACTS
AUSTRALIA
Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3833
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk E.Mail: sales@blue-seal.co.uk Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711 Spares: (tel): +44 121 322 6640 (fax): +44 121 327 9201 Service: (tel): +44 121 322 6644 (fax): +44 121 327 6257
UNITED STATES
Moffat Web: www.moffat.com Sales: (tel): 800 551 8795 (Toll Free)
(tel): +1 336 661 1556 (fax): +1 336 661 9546 Service: (tel): 800 858 4477 (Toll Free) (tel): +1 336 661 1556 (fax): +1 336 661 1660
REST OF WORLD
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
Contents List
Waldorf Gas Static Oven Range
RN(L)8510G Gas Range Static Oven - 750 mm wide. RN(L)8610G Gas Range Static Oven - 900 mm wide. RN(L)8810G Gas Range Static Oven - 1200 mm wide.
Introduction .............................................................................................. 2
Specification .............................................................................................. 3
Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection
Dimensions ................................................................................................ 5
Installation ................................................................................................ 8
Installation Requirements Unpacking Location Clearances Assembly Gas Connection Commissioning
Operation.................................................................................................11
Operation Guide Description of Controls Open Burners Griddle Lighting the Oven Pilot Burner Lighting the Oven Main Burner Turning the Oven to ‘Stand-By’ (Pilot ‘ON’ Only) Oven ‘Shut Down’
Cleaning and Maintenance ...................................................................... 15
General After Each Use Daily Cleaning Weekly Cleaning Periodic Maintenance
Fault Finding............................................................................................ 19
Gas Conversion and Specifications..........................................................20
Conversion Procedure Gas Specifications
Replacement Parts List............................................................................24
2
Introduction
We are confident that you will be delighted with your WALDORF GAS RANGE STATIC OVEN and it will become a most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Waldorf appliance, there are two important things you can do.
Firstly:
Please read the instruction book carefully and follow directions given. The time taken will be well spent.
Secondly:
If you are unsure of any aspect of installation, instructions or performance of your appliance, contact your BLUE SEAL dealer promptly. In many cases a phone call could answer your question.
CE Only:
These instructions are only valid if the country code appears on the appliance. If code does not appear on appliance, refer to supplier of this appliance to obtain technical instructions for adapting appliance to conditions for use in that country.
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF
FIRE.
 T
HE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
 I
T IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO
ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
 DO NOT
STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
Warning

This appliance is for professional use and is only to be used by qualified persons.

Only authorised service persons are to carry out installation, servicing or gas conversion operations.

Components having adjustments protected (e.g. paint sealed) by the manufacturer should not be adjusted by the user / operator.

DO NOT operate the appliance without the legs supplied fitted.
Caution
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
Warning
INSTRUCTIONS
TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
Warning
3
Specifications
Model Numbers Covered in this Specification
RN[1]8510G [2] Gas Range Static Oven, 4 Open Burners. RN[1]8513G [2] Gas Range Static Oven, 2 Open Burners, 300mm Griddle.
RN[1]8610G [2] Gas Range Static Oven, 6 Open Burners. RN[1]8613G [2] Gas Range Static Oven, 4 Open Burners, 300mm Griddle. RN[1]8616G [2] Gas Range Static Oven, 2 Open Burners, 600mm Griddle. RN[1]8619G Gas Range Static Oven, 900mm Griddle.
RN[1]8810G [2] Gas Range Static Oven, 8 Open Burners, 900mm, Storage Cabinet. RN[1]8813G [2] Gas Range Static Oven, 6 Open Burners, 300mm Griddle, Storage Cabinet. RN[1]8816G [2] Gas Range Static Oven, 4 Open Burners, 600mm Griddle, Storage Cabinet. RN[1]8819G [2] Gas Range Static Oven, 2 Open Burners, 900mm Griddle, Storage Cabinet.
NOTE:
[1]: - Back Options;
- - Standard Models. L - Low Back Models.
[2]: - Open Burner Options;
F - With Flame Failure Protection. PF - With Pilot and Flame Failure Protection.
General
A heavy duty, general purpose gas range created for compact modular kitchens. It has a high option Cook Top / Griddle arrangement and is available on industrial adjustable feet or on robust rollers.
Open Burners are available in either 'PF' (Pilot and Flame Failure) or 'F' (Flame Failure Only) options. Open Burner and Griddle options are fitted with individual flame failure for each open burner. Griddles are fitted with pilot, flame failure and piezo ignition as standard. Easy clean stainless steel external finish. The oven is fitted with pilot and flame failure with piezo ignition and a 30MJ oven burner.
4
Specifications
Gas Supply Requirements
- Non - CE Only:
- CE Only
Appliance Classification
Category: II
2H3P
(20, 30 / 37).
Flue Type: A1.
(
*
) Burner operating pressure is to be measured at manifold test point with two burners operating
at full setting. Operating pressure is ex-factory set, through appliance regulator and is not to be adjusted, apart from when carrying out gas conversion, if required. (Refer to ‘Gas Conversion’ section for details).
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand side, 32mm from rear and 655mm from floor and is reached from beneath appliance. (Refer to ‘Dimensions’ section).
Connection is ¾" BSP male thread.
Natural Gas (G20) Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Oven
Open Burner
(each)
Griddle
(each 300mm section)
Oven
Heat Input (nett)
Nominal 6.5 kW 5.5 kW 8.0 kW 6.5 kW 5.5 kW 8.0 kW Reduced 1.75 kW 1.85 kW 2.4 kW 1.75 kW 1.95 kW 2.4 kW
Gas Rate (nett)
Nominal 0.69 m3/hr 0.58 m3/hr 0.85 m3/hr 0.51 kg/hr 0.43 kg/hr 0.62 kg/hr Reduced 0.19 m3/hr 0.20 m3/hr 0.25 m3/hr 0.14 kg/hr 0.15 kg/hr 0.19 kg/hr
Supply Pressure
20 mbar 30 / 37 mbar
Operating Pressure
9.5 mbar 26 mbar
Gas Connection
3
/4” B.S.P. Male
Natural Gas LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
(26,540 Btu/hr)
28 MJ/hr
(26,540 Btu/hr)
- each 300 mm Griddle Section
21 MJ/hr
(19,900 Btu/hr)
21 MJ/hr
(19,900 Btu/hr)
- Oven
30 MJ/hr
(28,434 Btu/hr)
30 MJ/hr
(28,434 Btu/hr)
Supply Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa (11” - 18” w.c.)
Burner Operating Pressure
0.95 kPa (*) (3.7” w.c.)
2.6 kPa (*) (10” w.c.)
Gas Connection
3
/4” B.S.P. Male
5
Dimensions
RN
(L)
8510G
Cook Top Options
RN(L)8510G
RN(L)8513G
6
Dimensions
RN
(L)
8610G
Cook Top Options
RN(L)8610G
RN(L)8613G
RN(L)8616G
RN(L)8619G
7
Dimensions
RN
(L)
8810G
Cook Top Options
RN(L)8810G
RN(L)8813G
RN(L)8816G
RN(L)8819G
Loading...
+ 19 hidden pages