Wagner Meters Orion 930, Orion 920 Instruction Manual

INSTRUCTION MANUAL
TABLE OF CONTENTS
1 Introduction
4 Orion® 930 Parts
5 Quick Start: Basic Use for Solid Wood
11 Function Buttons: Detailed
– ON/HOLD Button
– UP and DOWN Buttons
– DEPTH Button
– SPECIES/MATERIAL Button
• How to Program a Species Setting
• Relative Scale for Moisture
Measurement of Non-Wood
Building Materials
– AUDIO Button
23 Summary of Orion® 930 Features
– Low Battery Alert Indication
– Auto Shut-Down to Preserve Battery Life
– Calibration of your Orion® 930
– Protective Rubber Boot for Your Orion® 930
– 7-Year Warranty
– Wagner’s IntelliSenseTM Technology
30 Specications
31 Changing the Battery
31 Meter Storage
32 Warranty
1 2
Congratulations!
You have purchased one of the most accurate moisture measurement instruments for wood in the world. Using IntelliSenseTM technology, hand-held moisture meters from Wagner Meters have been proven by universities and institutes worldwide to provide superior measurement results.*
With its electromagnetic eld, your Orion®
930 moisture meter covers a relatively large cross-sectional area each time you take a reading, giving you a far better representation than other technologies of the true moisture content of your wood.
Wagner moisture meters read IN the wood, not just on the wood.
INTRODUCTION
The 2.0-inch (50mm) wide by 2.5-inch (63mm) long by either .25-inch (6mm)
or .75-inch (19mm) thick sensor eld
of your Orion® moisture meter closely approximates the full-thickness cross­section method used when performing the ASTM D4442-16 oven-dry lab method. This ASTM standard (and its international counterparts) is the standard to which all moisture meters for wood are compared for accuracy.
Your Orion® 930 is best-suited for wood thicknesses from .25 inches (6mm) up to
1.5 inches (38mm). The meter can be used on non-solid wood products, and the Species Setting Booklet includes a few settings for some of these common materials.
In the Standard Measurement mode, your Orion® 930 measures moisture content within the 4.0% to 32.0% moisture content range.
NOTE: Measurement range may vary slightly depending on species setting of the meter.
3 4
The Orion® 930 has an easy-to-read digital display, scaled in 0.1% increments when in the Standard Measurement mode for your solid wood applications.
Wagner hand-held moisture measurement technology is virtually unaffected by wood temperature.**
Since 1965, Wagner Meters has been providing quality moisture measurement equipment and Wagner’s technology has been proven to provide some of the most accurate results in the industry when compared to the ASTM D4442-16 Standard. Wagner meters have been used for years by professional lumber-grading associations, and meters from Wagner continue to provide reliable and consistent moisture measurements, with unsurpassed convenience and ease of use.
*Information available upon request.**Contact a Wagner Meters expert at 844-689-0660 if your wood is very hot or frozen.
LCD
ON/ HOLD
BUTTON
SPECIES/
MATERIAL
BUTTON
DOWN
BUTTON
UP BUTTON
AUDIO
BUTTON
ORION 930 PARTS
BATTERY
COMPART-
MENT
(Meter Serial
Number is located in this compartment)
SENSOR
PLATE
®
DEPTH
BUTTON
5 6
Press the ON/HOLD button to store the setting and return the meter to the Reading mode.
Next, press the SPECIES/ MATERIAL button once, and the current species setting
(calibrated to specic gravity)
will appear. The factory default displayed will be 0.50 for a new meter. Use the UP or DOWN arrow buttons to set the correct species setting for the wood species you wish to measure (refer to your Species Settings Booklet
to nd the correct setting).
Finally, press the ON/HOLD button to place the meter back in the Standard Measurement mode.
NOTE: If you cannot nd the correct setting
for the wood species or material you wish to measure, go to www.wagnerspecies.com where you can access Wagner’s extensive
Species Database. If you still cannot nd
the correct setting, contact a Wagner Meters expert at 844-689-0660.
With your Orion® 930 turned OFF, press and release the ON/HOLD button. Meter will turn
on and briey display the model number, followed by the rmware revision number. If this is the rst time
you are using your new Orion® 930, immediately after the revision number is displayed, the meter display should revert to Standard Measurement mode, with the display showing 0.0% when the meter is held in the air. If meter display does not show
0.0%, then refer to page 15 regarding the SPECIES/MATERIAL button.
Next, press the DEPTH
button to put the meter in
the Depth Setting mode and
press either the UP button,
DOWN button or DEPTH button. The Depth setting will change from 3-4 or ¾” to 1-4 or ¼” or vice versa.
QUICK START
BASIC USE FOR SOLID WOOD
7 8
To make sure that you are getting the most accurate readings from your Orion® 930 meter, Wagner Meters recommends that you pay close attention to the following guidelines:
1. If the thickness of the piece of wood or other building material is greater than .75 inch (19mm), and you wish to get more of a full thickness rather than a shallow measurement, it is a good idea to take measurements in 3/4” mode on both sides and average the readings.
2. To prevent high or inaccurate readings, always have a minimum 1-inch (25mm) air gap underneath the piece of wood you are measuring. During this process make sure your hand is not directly underneath the meter.
CORRECT USAGE GUIDELINES
FOR YOUR ORION® 930
MOISTURE METER
A small DP will appear in the lower left corner of the screen to visually indicate that you are in 3-4 (¾”) Depth Setting mode (Deep mode).
Grasping the meter on the sides, begin taking measurements on the face of the
wood pieces by pressing down rmly,
making sure the rectangular sensor plate area on the back of the meter is pressing
rmly on the wood surface and completely
covered by the wood. Minimum wood dimension needs to be 2.0 inches (50mm) wide by 2.5 inches (63mm) long by .75 inches (19mm) in thickness. When taking measurements, make sure there is a 1-inch (25mm) minimum air gap underneath the wood you are measuring (refer to Correct Usage Guidelines section of this manual).
When you are nished
taking measurements and wish to turn the meter off, press the ON/HOLD
button for approximately 2 seconds. Alternatively, the meter will automatically shut off after approximately 60 seconds of no activity.
9 10
If the sensing area is not completely covered, your moisture reading will be inaccurate.
5. If there is visible moisture or water on the surface of the wood or material to be tested, wipe off any excess, and let the surface dry out for a couple of minutes before taking measurements. If possible, turn the board over and measure the other side.
6. Be sure to press down rmly to ensure good sensor plate contact with the surface of the wood or building material. This is especially important when measuring rough-sawn lumber.
7. Do not take readings where there is a noticeable defect or knot in the lumber.
Our Technical Staff Wants to Help You:
Please contact us at our worldwide toll­free number, 844-689-0660, for specic guidelines on how to properly measure wood
3. Your Orion® 930 meter was designed for wood thicknesses from .25 (6mm) to .50 (13mm) in ¼” mode and .75 inches (19mm) up to 1.5 inches (38mm) in ¾” mode. If you wish to measure wood pieces with thicknesses less than .75 inches (19mm) in ¾” mode, the meter will underestimate the actual moisture content. Thicknesses that are slightly thinner (example: .625 inches (15.9mm)) will not be underestimated substantially, but the thinner the piece becomes, the more the measurement will be underestimated. For pieces thinner than .50 inches (12.7mm), it is recommended that you use the ¼” mode.
4. The actual sensing area is a 2.0-inch (50mm) wide by 2.5-inch (63.5mm) long rectangle on the back of the meter (opposite side of the display and keypad). In order to take a valid measurement, this sensing area must be completely covered with the wood or other material you are measuring.
Loading...
+ 14 hidden pages