WAFER DC200 User Manual

WAFER GSM-KEY-DC REMOTE CONTROL UNIT
GSM-KEY-DC MANUAL
DC200 VERSION 5.0
SHANGHAI WAFER MICROELECTRONICS CO.,LTD
http://www.waferstar.com
WAFER GSM-KEY-DC REMOTE CONTROL UNIT
GSM-KEY OPERATING INSTRUCTIONS
WAFER GSM-KEY is an electronic board with an on-board GSM modem.The purpose of this device is to open an electric gate by means of a GSM phone.It has a door open relay whose contact has to be connected in parallel with the button which opens the gate. It has a White List of numbers who are enabled to open the phone, up to 200. When the GSM-KEY receives a call, it will check to see if the calling number is in the list. If it is in the list it will reject the call (so there will be no charge -at least with today's charging procedures) and click the relay momentarily.
Also GSM-KEY has two alarm input port for the security detection including the intruder detection alarm and gate problem alarm.
CONNECTOR DESCRIPTION
(For door opener application,that we use: NC1 COM1 NO1)
(When ALM1 or ALM2 switched to GND, then would trigger the alarm information)
ADVANTAGES OF WAFER GSM-KEY
ˇ 200 Regular User Numbers memory.
ˇ SHL50+PHL50+QHL550 ,total 800 Special Numbers memory for time zone.
ˇ 5 Alarm Numbers memory.
ˇ Up to 100 logs stored in database.
ˇ No call charges to operate.
ˇ No line rental using ‘Pay as You Go’.
ˇ No key-fobs for children to lose.
ˇ Let visitors and deliveries in remotely.
ˇ Impossible to clone or intercept.
ˇ Caller ID confirmation for security.
ˇ Quick & easy number barring.
ˇ Easy programming in minutes with your phone or PC software.
http://www.waferstar.com
WAFER GSM-KEY-DC REMOTE CONTROL UNIT
INSTALLATION
To install the GSM-KEY, you need to connect the 2 wires of the relay contact in parallel with the gate opening button. The relay contacts can stand 48V 0.5A maximum, this is enough for its operation but don't try to switch higher voltages or currents. You should install the GSM-KEY in a place where there is GSM signal coming from the operator you want to use. Check it with a phone before proceeding with the installation. If you need to install the device in a place with little signal, you may consider using an external antenna that we may supply as an option to be purchased separately with 50cm cable.
You should then insert the SIM Card of the operator you want to use with the right direction as the left picure.
!Note! : You must remove the PIN request from the SIM before inserting it in the unit, otherwise the device will not work. In order to
do so, insert the SIM in a phone and disable the PIN request (usually there is a security menu that enables you to do so).
GSM-KEY also comes with additional 2 Input.The inputs can be used to generate alarms when triggered.For examples,you can can connect the saftey beam output to the GSM-KEY Alarm1 and Alarm2 input.
WAFER GSM-KEY PROGRAMMING
You can program the GSM-KEY with SMS commands using your phone. It is safe to do so because in addition to the fact that other people may not know the number of the SIM inserted in it, we also use a Password that makes it impossible for anybody who doesn't know it to access the system by chance.
Remember that commands must be CAPITAL LETTERS. It is PWD not pwd, CAP not Cap etc. Don't add spaces or any other character.
Some complicated Instructions,that cann’t be programmed by the phone SMS. That would need to use the PC software to program and inquire the status of the terminal.
The bellow wire picture is to show how to connect the cable to the PC program connector with the Program adapter.Please connect it in the right direction with the picture.
Simple RS232 program card ( Standard ) USB program adapter box (Optional Parts)
http://www.waferstar.com
WAFER GSM-KEY-DC REMOTE CONTROL UNIT
GSM-KEY PC Program Software interface
1. Setting and Log page switch
2. Open saved file
3. Save units phone numbers in your computer for future changes
4. Save in a new file name
5. Communitcaton selection ,Com port configuration
6. Connect to the unit
7. Select Language
8. Setting Tab – Insert regular/Special phone numbers,miscellaneous
9. Log Tab
10. Phone numbers Tab – Add regular phone numbers 200
11. Special phone numbers Tab – Add special phone numbers 750
12. Alarm Phone numbers Tab – Add alarm phone numbers 5
13. Miscellaneous Tab
The following compand is used in the GSM-KEY :
#PWD: Password
#CAP: Change password
#WHL: White List (add or remove numbers)
#GOT: Gate pulse time
#ALARM: Alarm information setting
#MODE: Relay mode
#CSQ: Check Signal Quality
#SCA: Set service center address
#STATUS: Check status
#OUT: Use the SMS to control the switch to ON or OFF
Once you issue a command with an SMS, you will receive a confirmation SMS with OK if everything is correct or Err if there is an Error.
http://www.waferstar.com
WAFER GSM-KEY-DC REMOTE CONTROL UNIT
GSM-KEY SMS COMMAND LIST:
#PWD Password.
This command must always come first 6 digits as a password. The standard default one, when the device comes from the factory, is 123456. We suggest that you change it, using the #CAP command. In all the following examples we will use 123456 as an example of password.
#CAP Change Password.
Use this command to change the password with a new one that you will chose for your device ( don't forget it or you will have to send the unit back to us to reset it, and this has a cost ) The #CAP command must be issued 2 times to be sure you don't digit a wrong one. OF course it must be preceded by the old password. For example, to change the password 123456 into the new password 333444 you need to send the following SMS:
#PWD123456#CAP333444#CAP333444
Acknowledge SMS: PWD SETUP OK If you wrote correctly, or an Error message if you made a mistake. If the old password is error,then conformation would be : Error Old Password If you input two different new password,then reply would be : Error New Password,Please Check the
input again
#WHL White List. This is the command that you will use most. it is used to add or remove numbers that are enabled to open the gate into the White List. You can add up to 200 numbers in the list. Every position must be indicated in the command and we advise you to keep a list written somewhere to know which numbers are in and in which position.
• To add a number, the syntax of the command is the following:
#PWD123456#WHL001=61143815
Acknowledge would be : WHL01 SET TO 61143815 OK Where 01 is the position in the list and 61143815 is the number enabled. Please note that it is possible to program up to a maximum of 10 digits for a number. If it has more digits you should use the rightmost ones. For example, if your number is 33446665555 you should program 3446665555. If your number appears as +85261143815 you should not program the country code (+852). If your number has only 9 digits or less, it is not a problem. The important thing is that you don't exceed 10 digits.
• To check which is the number in a place of the list:
#PWD123456#WHL001?
Acknowledge : WHL001 IS 61143815 OK
• To erase a number:
#PWD123456#WHL001=0000000
(or you can write over it another number you wish to add) Acknowledge :
WHL001 SET TO 00 00 00 00