Waeco CoolFreeze CF-80, CoolFreeze CF-110 Instruction Manual

Page 1
M_70501
CF-80 AC
CF-110 AC
CF-80, CF-110
AAUUSS
Compressor Cooler Instruction Manual
Page 2
3
CoolFreeze
Please read this operating manual carefully before starting the device.
Keep it in a safe place for future reference. If the device is handed over to another person, this operating manual must be handed over along with the device.
Contents
1. Notes on using the manual ....................................... 7
2. Safety instructions ....................................... 7
2.1 General safety ....................................... 7
2.2 Operating the device safely ....................................... 8
3. Scope of delivery ....................................... 9
4. Intended use ....................................... 9
5. Function description ....................................... 10
5.1 Operating and display elements ....................................... 10
5.2 Connections ....................................... 11
6. Operation ....................................... 11
6.1 Before initial use ....................................... 11
6.2 Energy saving tips ....................................... 12
6.3 Connecting the cooler ....................................... 12
6.4 Using the battery monitor ....................................... 14
6.5 Using the cooler ....................................... 15
6.6 Setting the temperature ....................................... 16
6.7 Using the emergency switch ....................................... 16
6.8 Switching off the cooler ....................................... 16
6.9 Defrosting the cooler ...................................... 16
6.10 Replacing the device fuse ....................................... 17
6.11 Replacing the light bulb ....................................... 17
7. Cleaning and maintenance ....................................... 17
8. Guarantee ....................................... 18
9. Troubleshooting ....................................... 18
10. Disposal ....................................... 19
11. Technical data ....................................... 19
Page 3
4
CoolFreeze
1
2
3
1
°
2
4
3
1 3 4 5 6 72
ON
OFF
POWER
ERROR
1
100-240V~AC
SET
2
FUSE
°
34
12/24V DC
UP
+
DOWN
Page 4
5
CoolFreeze
O
N
O
F
F
T
U
R
B
O
P
O
W
E
R
E
R
R
O
R
C
T
E
M
P
+
T
E
M
P
ñ
O
N
O
F
F
T
U
R
B
O
P
O
W
E
R
E
R
R
O
R
C
T
E
M
P
+
TE
M
P
ñ
1
2
4
5
Page 5
6
CoolFreeze
6
8
O
N O
F
F
T
U
R
B
O
P
O
W
E
R
E
R
R
O
R
C
T
E
M
P +
T
E
M
P ñ
7
1 2
Page 6
7
CoolFreezeNotes on using the manual
1. Notes on using the manual
The following symbols are used in this operating manual:
Caution! Safety instruction: Failure to observe this instruction can cause personal
injury or damage the device.
Caution! Safety instruction: relating to a danger from an electrical current or
voltage. Failure to observe this instruction can cause injury or damage the device and impair its function.
Note: Supplementary information for operating the device.
Action: This symbol indicates that action is required on your part.
The required action is described step-by-step
This symbol indicates the result of an action
Fig. 2 1, page 4: This refers to an element in an illustration.
In this case, item 1 in figure 2 on page 4.
Please observe the following safety instructions.
2. Safety instructions
Caution!
WAECO International will not be held liable for claims for damage resulting from the following: – Damage to the device resulting from mechanical influences and over
voltage.
– Alterations to the device made without the explicit permission of
WAECO International.
– Use for purposes other than those described in the operating manual.
2.1 General Safety
Caution – Danger of electrocution
When using the device on boats: If the device is powered by the mains, ensure that the power supply is protected with a ground fault interrupter circuit.
Check that the voltage specification on the type plate corresponds to
that of the energy supply.
Page 7
8
CoolFreeze
Safety Instructions
Only connect the device as follows:
– using the cable supplied (Fig. 1 2, page 4) to a 12- V or 24- V
battery
– or with the AC cable supplied (Fig. 1 3, page 4) to the
100–240V AC mains.
If the connection cable is damaged, it must be replaced to prevent
possible electrical hazards.
Do not pull the plug out of the cigarette lighter or the socket by the
cable.
Pull out the connection cable:
– Before cleaning and maintenance – After use – Before changing a fuse.
Disconnect the cooling device and other power consuming devices
from the battery before you connect the battery to a quick charging device. Overvoltage can damage the electronics of the device.
Electronic devices are not toys!
Always keep and use the device out of the reach of Children
Do not operate the device if it is visibly damaged.
This device may only be repaired by qualified personnel.
Inadequate repairs can lead to considerable hazards. Should your device need to be repaired, please contact WAECO customer service.
Do not open the refrigerant circuit under any circumstances!
The cooler is not suitable for transporting caustic materials or materials
containing solvents.
Food may only be stored in its original packaging or in suitable
containers.
2.2 Operating the device safely
Warning! – Danger of electrocution
Do not touch exposed cables with your bare hands.This especially applies when operating the device from an AC mains.
Before starting the device, ensure that the power supply line and the
plug are dry.
Page 8
9
CoolFreeze
Intended use
Warning!
Do not place any electrical devices inside the cooler.
Set up the device in a dry location where it is protected against
splashing water.
Protect the device and the cable against rain and moisture.
Do not place the device near naked flames or other heat sources
(heaters, direct sunlight, gas ovens etc.)
Warning! Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the heat generated during normal operation is able to dissipate. Ensure that the ventilation slots are not covered. Make sure that the device is sufficiently far away from walls and other objects so that the air can circulate.
Never immerse the device in water.
Do not fill the inside with fluid.
3. Scope of delivery
Fig. 1 , page 4, shows the scope of delivery.
Item Quantity Description
1 1 Cooler 2 1 Connection cable for 12/24 V DC connection 3 1 connection cable for 100-240V AC connection 4 2 Carrying handle, consisting of 2 holders,
1 handle, 4 screws
- 1 Operating manual
- (CF-80) 2 Internal basket
- (CF-80) 2 Internal compartment divider (plastic)
- (CF-110) 1 Internal basket with wire dividers (2 off)
4. Intended use
The cooler is suitable for cooling and freezing foods. The device is also suitable for use on boats.
The appliance is designed for use with a 12 V DC or 24 V DC battery in a car, boat or caravan, or on a 100-240 V AC mains supply.
Caution – When cooling perishable medicines!
If you wish to cool medicines, please check if the cooling capacity of the device is adequate for this purpose.
Page 9
10
CoolFreeze
Function description
5. Function description
The cooler can chill products, keep them cool as well as freeze them. A low maintenance, CFC-free refrigerant circuit with compressor provides the cooling. The extra strong CFC-free insulation and powerful compressor ensure especially fast cooling.
The cooler is portable and can be carried by two detachable handles.
When used on boats, the cooler can be withstand a constant heel (inclination) of 30°C .
Scope of functions:
Power pack with priority circuit for connecting to the AC mains.
3-level battery monitor for protecting the vehicle battery.
Programmed turbo mode for rapid cooling.
Display with temperature gauge.
Temperature adjustment.
(with two buttons in steps of 1°C (2°F)).
Detachable carrying handles.
Emergency override switch for ‘limp home’ mode.
5.1 Operating and display elements
Operating panel (Fig. 2 , page 4)
Item Description Explanation
1 ON Switches the cooler on or off when the button
OFF is pressed for between one and two seconds
2 POWER Status indication
LED lights up green: Compressor is on LED lights up orange: Compressor is off
3 ERROR LED flashes red: Device is switched on
but not ready for operation
4 SET Selects the input mode
- Temperature setting
- Celsius or Fahrenheit display
- Set battery monitor 5 Display, shows the information 6 UP + Press once to increase the value 7 DOWN – Press once to decrease the value
Page 10
11
CoolFreeze
Operation
5.2 Connections
Connection sockets (Fig. 3 , page 4)
Item Description
1 Connection socket AC voltage supply 2 Fuse holder 3 Connection socket DC voltage supply 4 Emergency switch
6. Operation
6.1 Before initial use
Note:
Before starting your new cooler for the first time, you should clean it inside and outside with a damp cloth for hygienic reasons (please also refer to “Cleaning and maintenance” on page 17)
The handles are enclosed unassembled. If you wish to attach the handles, proceed as follows: Make a handle by putting two holders (Fig. 4 1, page 5) and a
handle (Fig. 4 2, page 5) together.
Fasten the holders with the enclosed screws in the holes provided.
Selecting the temperature units – ºC or ºF
You can switch the temperature display between Celsius and Fahrenheit. This is how to do it:
Switch on the cooler. Press the “SET” button (Fig. 2 4, page 4) twice. Use the “UP +” (Fig. 2 6, page 4) and “DOWN -” (Fig. 2 7,
page 4) buttons to select Celsius or Fahrenheit.
The selected temperature units then appear in the display for a few
seconds. The display flashes several times before it returns to the current temperature.
Turning the lid around
You can turn the lid around if you want to open the lid from the other side. To do this, proceed as follows: Undo the screws on the lock lugs (Fig. 5 1, page 5) and remove
them.
Undo the screws on the hinges (fig. 5 2, page 5) and remove them. Lay the lid down. Fit the hinges on the side you want. Fit the lock lugs on the side you want.
Page 11
12
CoolFreeze
Operation
6.2 Energy saving tips
Choose a well ventilated installation location which is protected from
direct sunlight.
Allow hot food to cool down first before you place it into the device.
Do not open the cooler more often than necessary.
Do not leave the lid open for longer than necessary.
Defrost the cooler once a layer of ice forms.
Avoid unnecessarily low temperature settings.
6.3 Connecting the cooler
Connecting to a battery (Vehicle or boat)
The cooler can be operated with 12 V or 24 V DC, either using cigarette plug lead supplied, or plug removed and “hard wired” as follows:
Caution – Danger of damaging the device!
Disconnect the cooler and other consumer units from the battery before you connect the battery to a quick charging device. Overvoltage can damage the electronics of the device.
For safety reasons the cooler is equipped with an electronic system to prevent polarity reversal. This protects the cooler against short-circuiting when connecting to a battery.
Caution – Danger of damaging the device!
For fixed installations where cigarette plug is removed, and if cable is extended, to avoid drops in voltage and therefore performance, keep the cable as short as possible and only disconnect it when necessary. For this reason avoid additional switches, plugs or power strips.
Determine the required cross section of the cable in relation to the
cable length according to Fig. 6 , page 6.
Key for Fig. 6 , page 6
Co-ordinate axis Meaning Unit
I Cable length m
ø Cable cross section mm
2
Page 12
13
CoolFreeze
Operation
Caution – Danger of damaging the device!
Make sure that the polarity is correct.
Before starting up the device for the first time, check whether the
operating voltage and the battery voltage correspond (see type plate).
Make sure that the cable at the positive battery terminal (Fig. 7 2,
page 6) is protected with a 15 A (12V) fuse (Fig. 7 3, page 6) fitted as close to battery as possible.
Plug the 12/24-V connection cable (Fig. 1 2, page 4) into the DC
socket on the cooler (Fig. 7 1, page 6).
Connect the red cable (Fig. 7 red, page 6) to the positive terminal
of the battery (Fig. 7 2, page 6).
Connect the black cable (Fig. 7 black, page 6) to the negative
terminal of the battery (fig. 7 2, page 6).
Connecting to a 100-240V AC mains (E.g. in the home or office)
Caution – Danger of electrocution!
Never handle plugs and switches with wet hands or if you are standing on a wet surface.
Caution – Danger of electrocution!
If you are operating your cooler on board a boat from a mains connection of 100-240 V AC, you must install a residual current circuit breaker between the 100-240 V AC mains and the cooler. Seek advice from a trained technician.
The cooler has a built-in multi-voltage mains adapter with a priority circuit for connecting to a 100-240V AC supply. The priority circuit automatically switches to mains operation if the appliance is connected to a 100–240 V AC supply, even if the 12/24 V cable is still connected.
When switching between the AC mains and the battery supply, the red LED may light up briefly.
Plug the 100–240 V connection cable (Fig. 1 3, page 4) into the AC
voltage socket and connect it to the 100–240 V AC voltage mains.
Page 13
14
CoolFreeze
Operation
6.4 Using the battery monitor.
The device is equipped with a multi-level battery monitor that protects your vehicle battery against excessive discharging when the device is connected to the on-board 12/24 V supply.
If the cooler is operated when the vehicle ignition is switched off, the cooler switches off automatically as soon as the supply voltage falls below a set level. The cooler will switch back on once the battery has been recharged to the restart voltage level.
Caution – Danger of damage!
When switched off by the battery monitor, the battery will no longer be fully charged. Avoid starting repeatedly or operating current consumers without longer charging phases. Ensure that the battery is recharged.
In “HIGH” mode, the battery monitor responds faster than the levels “LOW” and “MED” (see the following table).
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V 10.1 V 11.4 V 11.8 V Restart voltage at 12 V 11.1 V 12.2 V 12.6 V Switch-off voltage at 24 V 21.5 V 24.1 V 24.6 V Restart voltage at 24 V 23.0 V 25.3 V 26.2 V
This is how to select the battery monitor mode:
Switch on the cooler. Press the “SET” button (Fig. 2 4, page 4) three times. Use the “UP +” (Fig. 2 6, page 4) and “DOWN -” (Fig. 2 7,
page 4) buttons to select the battery monitor mode.
Digital Display will be as follows:
The selected mode then appears in the display for a few seconds.
The display flashes several times before it returns to the current temperature.
Note:
When the cooler is supplied by the starter battery, select the battery monitor mode “HIGH”. If the cooler is connected to a supply battery, the battery monitor mode “LOW” will suffice.
If you wish to operate the cooler from the AC mains, set the battery monitor to the “LOW” position.
(LOW) (MED) (HIGH)
Page 14
15
CoolFreeze
Operation
6.5 Using the cooler
Caution – Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the heat generated during operation can dissipate. Ensure that the ventilation slots are not covered. Make sure that the device is sufficiently far away from walls and other objects so that the air can circulate.
Place the cooler on a firm foundation.
Make sure that the ventilation slots are not covered and that the heated air can dissipate.
Close the cooler, see “Connecting the cooler” on page 12.
Note:
If you wish to operate the cooler from the AC mains, set the battery monitor to the “LOW” position. See “Using the battery monitor” on page 14.
Caution – Danger from excessively low temperature!
Ensure that the only objects placed in the cooler are those intended to be cooled at the selected temperature.
Press the “ON/OFF” button (Fig. 2 1, page 4) and hold down for
between one and two seconds.
The ‘POWER” LED is lit green. The display (Fig. 2 6, page 4) switches on and shows the current
temperature in °C.
Note – Displayed temperatures
CF-80
i) With plastic dividers in: the display temperature is that of the
middle of the freezer compartment (furthest away from main control panel).
ii) With plastic dividers removed: the actual compartment temperature
will be considerably warmer than the displayed temperature.
CF-110
i) The temperature displayed is that of the middle of the large interior
compartment. Temperatures elsewhere in the compartment (both models) will deviate from the displayed temperature.
The cooler starts cooling the interior.
Page 15
16
CoolFreeze
Operation
6.6 Setting the temperature
Press the “SET” button (Fig. 2 4, page 4) once. Use the “UP +” (Fig. 2 6, page 4) and “DOWN -” (Fig. 2 7,
page 4) buttons to select the cooling temperature.
The cooling temperature appears in the display for a few seconds.
The display flashes several times and then the current temperature is displayed again.
6.7 Using The Emergency Switch
The emergency override switch (Fig. 3 4, page 4) is located in
the connection panel.
For normal operation the switch should be in the ‘NORMAL USE’
position.
In the unlikely event of an electronic control failure slide the Switch
to ‘EMERGENCY OVERRIDE’. NOTE: in this position the appliance will run all the time and will therefore perform as a freezer only.
6.8 Switching off the cooler
Empty the cooler. Switch the cooler off. Pull out the connection cable.
If you do not want to use the cooler for a longer period of time:
Leave the cover slightly open. This prevents odour build-up.
6.9 Defrosting the cooler
Humidity can form frost in the interior of the cooling device or on the evaporator. This reduces the cooling capacity. Defrost the device in good time to avoid this.
Warning! – Danger of damaging the device!
Never use hard or pointed tools to remove ice or to loosen objects which have frozen in place.
To defrost the cooler, proceed as follows:
Take out the contents of the cooling device. If necessary, place them in another cooling device to keep them
cool. Switch off the device.
Leave the lid open. Wipe off the defrosted water.
Page 16
17
CoolFreeze
Operation
6.10 Replacing the device fuse
Caution – Danger of electrocution!
Disconnect the connection cable before you replace the device fuse.
Pull off the connection cable.
6.11 Replacing the light bulb
Press the switch pin (Fig. 8 2, page 6) downwards so that the
transparent part (Fig. 8 1, page 6) of the lamp can be removed at
the front. Replace the light bulb ensuring that:
i) the LED’s inside the bulb face toward the transparent cover. ii) the polarity is correct. Test for operation and if the new bulb does
not work fit it the other way around.
Press the lamp back into the housing.
7. Cleaning and maintenance
Caution – danger of electrocution!
Always pull out the mains plug on the power supply before you clean and service the device.
Caution – Danger of damaging the device!
Never clean the device under running water or in dish water. Do not use abrasive cleaning agents or hard objects during cleaning as these can damage the device. Never use brushes, scouring pads or hard or pointed tools to remove ice or to loosen objects which have frozen in place.
Occasionally clean the inside of the device with a damp cloth.
Page 17
18
CoolFreeze Troubleshooting
Possible cause
Battery voltage is too low.
No voltage present in the AC voltage socket.
The device fuse is defective.
The integrated mains adapter is defective.
Defective compressor.
Battery voltage is too low.
The appliance has switched off due to an internal fault.
Suggested remedy
Test the battery and charge it as needed. Try using another plug socket.
Replace the device fuse, see “Replacing the device fuse” on page 17. This can only be repaired by an authorised repair centre.
This can only be repaired by an authorised repair centre.
Test the battery and charge it as needed.
This can only be repaired by an authorised repair centre.
Fault
Device does not function, LED does not glow.
The device does not cool (plug is inserted, “POWER” LED is lit).
The device does not cool (plug is inserted, “ERROR” LED flashes).
The display shows an error message (e.g. “Err1”) and the appli­ance does not cool.
8. Guarantee
Our general guarantee conditions apply. If the product is defective, please take it to your nearest authorised WAECO repair agent. For repair and guarantee processing, please include the following documents when you send in the device:
A copy of the receipt with purchase date.
Reason for the claim or a description of the fault.
9. Troubleshooting
Page 18
10. Disposal
Place the packaging material in the appropriate recycling waste
bins wherever possible.
If you wish to finally dispose of the device, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
11. Technical data
CF-80 CF-110
Overall capacity: 80 litres 106 litres Connection voltage: 12/24 V DC and 100-240V AC Rated current:
– 12 V DC 7.5A – 24 V DC 3.5A
– 100-240 V AC 1.3 to 0.7A Cooling range: +10°C to - 18°C (+50°F to 0°F) Dimensions (WxHxD) in mm: 790x455x500 790x555x500 Weight: 29kg 32kg
Note:
If the ambient temperature is above 32°C, (90ºF), the minimum temperature cannot be attained.
Test/Certificates:
– 73/23/EEC – Low Voltage Electrical Equipment
Directive – 89/336/EEC – EMC Directive – 95/54/EEC
Versions, and delivery options may vary due to technical modifications. This device is CFC-free. The coolant circuit contains R134a.
19
CoolFreezeTechnical Data
Page 19
20
CoolFreeze
AAUUSS
NNZZ
Internet http://www.waeco.com.au
http://www.waeco.co.nz
WAECO Western Australia
9 Hod Way Malaga WA 6090 phone: 1800 21 21 21 fax: (08)9209 3577
WAECO New Zealand
Unit 15, 180 Montgomerie Road Airport Oaks, Auckland 1701 phone: 0800 676 000 fax: (09)256 0017 e-mail: info@waeco.co.nz
WAECO Victoria
1/97 Lewis Road Wantirna VIC 3152 phone: 1800 21 21 21 fax: (03)9800 1533
WAECO Pacific Pty. Ltd.
1 John Duncan Court Varsity Lakes, QLD, 4227 phone: 1800 21 21 21 fax: (07)5507 6001 e-mail: sales@waeco.com.au
Europe
WAECO (Schweiz) AG
Riedackerstrasse 7a CH-8153 Rümlang (Zürich) phone: +41 44 8187171 fax: +41 44 8187191 e-mail: info@waeco.ch
WAECO Danmark A/S
Tvaervej 2 DK-6640 Lunderskov phone: +45 75585966 fax: +45 75586307 e-mail: waeco@waeco.dk
WAECO Ibérica S.A.
Camí del Mig, 106 Poligono Industrial Les Corts E-08349 Cabrera de Mar (Barcelona) phone: +34 93 7502277 fax: +34 93 7500552 e-mail: info@waeco.es
WAECO Distribution SARL
ZAC 2 · Les Portes de L‘Oise Rue Isaac Newton – BP 59 F-60230 Chambly (Paris) phone: +33 1 30282020 fax: +33 1 30282010 e-mail: info@waeco.fr
WAECO Finland OY
Mestarintie 4 FIN-01730 Vantaa phone: +358 20 7413220 fax: +358 9 7593700 e-mail: waeco@waeco.fi
E
F
FIN
I
S
UK
NL
USA
HK
o
WAECO Italcold SRL
Via dell’Industria 4/0 I-40012 Calderara di Reno (BO) phone: +39 051 727094 fax: +39 051 727687 e-mail: sales@waeco.it
WAECO Norge AS
Leif Weldingsvei 16 N-3208 Sandefjord phone: +47 33428450 fax: +47 33428459 e-mail: firmapost@waeco.no
WAECO Benelux B.V.
Ecustraat 3 NL-4879 NP Etten-Leur phone: +31 76 5029000 fax: +31 76 5029090 e-mail: verkoop@waeco.nl
WAECO Svenska AB
Gustaf Melins gata 7 S-42131 Västra Frölunda (Göteborg) phone: +46 31 7341100 fax: +46 31 7341101 e-mail: info@waeco.se
WAECO UK Ltd.
Dorset DT2 8LY · Unit G Roman Hill Business Park UK-Broadmayne phone: +44 1305 854000 fax: +44 1305 854288 e-mail: sales@waeco.co.uk
Overseas + Middle East
WAECO Pacific Pty. Ltd.
1 John Duncan Court Varsity Lakes QLD 4227 phone: +61 7 55076000 fax: +61 7 55076001 e-mail: sales@waeco.com.au
WAECO Impex Ltd.
Suites 3210-12 · 32/F · Tower 2 The Gateway · 25 Canton Road Tsim Sha Tsui · Kowloon Hong Kong phone: +852 24632750 fax: +852 24639067 e-mail: info@waeco.com.hk
WAECO Impex Ltd.
Taipei Office 2 FL-3 · No. 56 Tunhua South Rd, Sec 2 Taipei 106, Taiwan phone: +886 2 27014090 fax: +886 2 27060119 e-mail: marketing@waeco.com.tw
WAECO Middle East FZCO
R/A 8, SD 6 Jebel Ali, Dubai phone: +971 4 8833858 fax: +971 4 8833868 e-mail: waeco@emirates.net.ae
WAECO USA, Inc.
8 Heritage Park Road Clinton, CT 06413 phone: +1 860 6644911 fax: +1 860 6644912 e-mail: customercare@waecousa.com
World Headquarters
WAECO International GmbH · Hollefeldstraße 63 · D-48282 Emsdetten phone: +49 2572 879-195 fax: +49 2572 879-322 e-mail: info@waeco.de Internet: www.waeco.de
D
DK
CH
N
AUS
ROC
UAE
Loading...