Mast
Width = 1.67 m
BASE STUBS
IN CONCRETE
76mm
CLEARANCE
152 x 152mm
WIRE MESH
NTS
DEPTH =
1.2 m
CONCRETE REQUIRED = 3.34 cu.m.
Clamp
Plates
DELHI LIGHTING TOWER PRODUCTS
LT SERIES
Lighting towers are available in the following four series. Load figures given are for lights mounted
at the top of the tower, and include the weight of mast and fittings. Each series designates the
load carrying capabilities and maximum height. Our new Towers have been enhanced in both leg
profile and taper facilitating an easier installation and improved tower structure.
NOTE: All ballasts should be mounted at base of tower.
8 foot
sections
Model
LT
LT
LT
LT
Series No.
1
2
3
4
Max. Height
64'
56'
48'
40'
3 sq. ft. projected area - 60 lbs of weight
6 sq. ft. projected area - 120 lbs of weight
9 sq. ft. projected area - 180 lbs of weight
12 sq. ft. projected area - 240 lbs of weight
Max. Load
For Parks and Recreational Areas, Farms, Industry, Parking Lots, and many other applications.
CONSTRUCTION
Towers are manufactured in 8 ft.
sections, which nest compactly for
shipping and ease of handling and
storage. Rivets are stainless steel and
all bolts, nuts and lockwashers are
heat treated and zinc plated.
TOP SECTIONS
The top section of each tower comes
complete with 2 heavy gauge
galvanized mast clamp plates. Each
plate has a heavy duty cast aluminum
mast clamp that will accept masts up
to 2 ½" O.D. (see figure below)
BASES - CONCRETE
Each tower is shipped with 3
concrete-base stubs. It is recommended
that a square hole be dug 4 feet deep
and 16" wider than the base section of
the tower. Hinge-up base stubs are also
available for use in concrete. These are
recommended where facilities are
available for raising or lowering complete
tower. On parking lot installations, all
concrete bases should extend past
bumper height.
CLIMB SHIELDS
(Also used to enclose ballasts)
Shields are manufactured from
galvanized sheet and are fastened to
the braces with sheet metal screw.
Shields are 8 feet high.
26" Sections 01T, 02T
A
41" Sections 03T, 04T
B
Climb
Shield
Hinge-up Base
Compact Tower
Package
Unique
beaded
channel
leg resists
bending
A
B
Top of tower with mast
clamp plate installed
DELHI LIGHTING TOWER PRODUCTS
LT SERIES
LT Series Towers are shipped complete with 8 foot tower sections, 2 mast clamp plates
installed in top section, 3 cement base stubs, plus special bolts, nuts and washers.
SECTIONS SUPPLIED THGIEWTHGIEHLEDOM (LBS )
LT-1-24N
LT-1-32N
LT-1-40N
LT-1-48N
LT-1-56N
LT-1-64N
LT-2-24N
LT-2-32N
LT-2-40N
LT-2-48N
LT-2-56N
LT-3-24N
LT-3-32N
LT-3-40N
LT-3-48N
LT-4-24N
LT-4-32N
LT-4-40N
24'
LTX-01T, LTX-02, LTX-03
32'
LTX-01T, LTX-02, LTX-03, LTX-04
40'
LTX-01T, LTX-02, LTX-03, LTX-04, LTX-05
48'
LTX-01T, LTX-02, LTX-03, LTX-04, LTX-05, LTX-06
56'
LTX-01T, LTX-02, LTX-03, LTX-04, LTX-05, LTX-06, LTX-07
64'
LTX-01T, LTX-02, LTX-03, LTX-04, LTX-05, LTX-06, LTX-07, LTX-08
24'
LTX-02T, LTX-03, LTX-04
32'
LTX-02T, LTX-03, LTX-04, LTX-05
40'
LTX-02T, LTX-03, LTX-04, LTX-05, LTX-06
48'
LTX-02T, LTX-03, LTX-04, LTX-05, LTX-06, LTX-07
56'
LTX-02T, LTX-03, LTX-04, LTX-05, LTX-06, LTX-07, LTX-08
24'
LTX-03T, LTX-04, LTX-05
32'
LTX-03T, LTX-04, LTX-05 LTX-06
40'
LTX-03T, LTX-04, LTX-05, LTX-06, LTX-07
48'
LTX-03T, LTX-04, LTX-05, LTX-06, LTX-07, LTX-08
24'
LTX-04T, LTX-05, LTX-06
32'
LTX-04T, LTX-05, LTX-06 LTX-07
40'
LTX-04T, LTX-05, LTX-06, LTX-07, LTX-08
86
118
165
223
291
359
97
144
202
270
338
124
182
250
318
158
226
294
SPECIFICATIONS OF SECTIONS
SECTION
NO .
LTX-01T
LTX-02
LTX-02T
LTX-03
LTX-03T
LTX-04
LTX-04T
LTX-05
LTX-06
LTX-07
LTX-08
GAUGE
LEG
16
16
16
16
16
16
16
14
13
12
12
CROSS
BRACE
GAUGE
18
18
18
18
18
16
16
14
14
14
14
( IN . )
12 ½
14 ¾
14 ¾
17
17
19 ½
19 ½
22
24
26
29
“ A”
“ B”
( IN . )
10
12 ¾
12 ¾
15
15
17 ½
17 ½
19 ¾
3
3
22
8
7
3
8
24 ¾
8
27 ¼
8
DIA
(IN .)
3
3
3
3
3
3
3
3
3
¼
¼
IN LBS
26
16
16
23
28
16
16
26
34
16
16
31
16
41
46
16
55
16
63
68
WEIGHT
RIVET
ACCESSORIES
MODEL
HUB 3-6
HUB 7-8
HINGE -UP BASE FOR CONCRETE
Fit sections LTX-03 thru LTX-06
Fit sections LTX-07 and LTX-08
CLIMB SHIELDS
CS-3
CS-4
CS-5
CS-6
CS-7
CS-8
to fit LTX-03 section
to fit LTX-04 section
to fit LTX-05 section
to fit LTX-06 section
to fit LTX-07 section
to fit LTX-08 section
Section numbers ending in “T” are
top sections which have 2 mast
clamp plates installed.
B
8'
Model
LT-3-48N
Climb Shields
A
www.wadeantenna.com
Installing three lights on a