INSTALLATION INSTRUCTIONS
Headquarters
44 Harbor Park Drive, Port Washington, NY
Phone (516) 515.5000 • Fax (516) 515.5050
www.waclighting.com
WAC Lighting (Shanghai)
14 Lane 299, Bi Sheng Road Shanghai 201204
Phone (86.21) 3393.3558 • Fax (86.21) 3362.1598
www.waclighting.com.cn
WAC Lighting - International sales
Room 3207-3208, Building 4,Tian An Cloud Park,
ShenZhen, Guangdong 518129
www.waclighting.io
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. April 22, 2019
1 / 6
A1. Mounting slots can be knocked out and are
spaced every 12 inches for convenience.
A2. Option A: Hang track from the surface using
toggle bolts (included).
3-Circuit Recessed Flanged Track System
Model: WT1M/2M/3M-RT-2
SAFETY INSTRUCTION
IMPORTANT: NEVER attempt any work without shutting off the electricity.
• Read all of these instructions before installing the track system.
• Turn off power at main switch before installing or modifying the system.
• Do not install within 15cm of any curtain or combustible materials.
• Do not install less than 1.5m above a floor.
• Do not install in damp or wet locations.
• Do not install concealed, or extended through building walls.
• Do not attempt to energize anything other than a track light fixture.
• Do not connect a track to more than one branch circuit. Although track light system may seem to operate
acceptably, a dangerous overload of the neutral may occur and result in a risk of fire.
• System is intended for installation by a qualified electrician in accordance with the National Electrical Code
and local regulations.
• All of the installations shall be in accordance with NEC and all local codes.
• Save these installation instructions and refer to them when additions or changes to the track configuration are
made.
MOUNTING OPTIONS
Surface mounting or suspension mounting can be selected according to different environments.
Do not fasten the track to the ceiling until all electrical connections have been installed.
A. Surface Recessed mounting
Ceiling Opening: 40±3mm

INSTALLATION INSTRUCTIONS
Headquarters
44 Harbor Park Drive, Port Washington, NY
Phone (516) 515.5000 • Fax (516) 515.5050
www.waclighting.com
WAC Lighting (Shanghai)
14 Lane 299, Bi Sheng Road Shanghai 201204
Phone (86.21) 3393.3558 • Fax (86.21) 3362.1598
www.waclighting.com.cn
WAC Lighting - International sales
Room 3207-3208, Building 4,Tian An Cloud Park,
ShenZhen, Guangdong 518129
www.waclighting.io
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. April 22, 2019
2 / 6
A2. Option B : Mount track flush to the surface
and secure screws (included).
A2. Option C :
T-Bar assembling.
B1. Stem suspension mounting
Tips:
Connect stems each other to
adjust the height. Just like
below:
B2. Cable suspension mounting
B3. Sloped ceiling mounting
3-Circuit Recessed Flanged Track System
Model: WT1M/2M/3M-RT-2
B. Suspension Mounting

INSTALLATION INSTRUCTIONS
Headquarters
44 Harbor Park Drive, Port Washington, NY
Phone (516) 515.5000 • Fax (516) 515.5050
www.waclighting.com
WAC Lighting (Shanghai)
14 Lane 299, Bi Sheng Road Shanghai 201204
Phone (86.21) 3393.3558 • Fax (86.21) 3362.1598
www.waclighting.com.cn
WAC Lighting - International sales
Room 3207-3208, Building 4,Tian An Cloud Park,
ShenZhen, Guangdong 518129
www.waclighting.io
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. April 22, 2019
3 / 6
Cut the track, insulation material, and copper busbars / Stem with one straight cut and remove any burrs that
may have resulted from the cut.
Option A: Feed end connector (WEDL/WEDR).
1 2
Tips:
- Feed power through the end:
The end of the plastic cover must be removed and
replaced with a rubber ring.
- Feed power throug the bottom:
The bottom cover must be pushed away.
3-Circuit Recessed Flanged Track System
Model: WT1M/2M/3M-RT-2
FIELD CUTTING
FEED OPTIONS:
• Make sure power is off before wiring.
• Note the polarity indicator of the track and accessories.

INSTALLATION INSTRUCTIONS
Headquarters
44 Harbor Park Drive, Port Washington, NY
Phone (516) 515.5000 • Fax (516) 515.5050
www.waclighting.com
WAC Lighting (Shanghai)
14 Lane 299, Bi Sheng Road Shanghai 201204
Phone (86.21) 3393.3558 • Fax (86.21) 3362.1598
www.waclighting.com.cn
WAC Lighting - International sales
Room 3207-3208, Building 4,Tian An Cloud Park,
ShenZhen, Guangdong 518129
www.waclighting.io
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. April 22, 2019
4 / 6
1. Drill a hole in the centre of the track (Diameter
16mm).
3. Wiring and installing junction.
2. Assemble WMD, Turn the knob 90 degrees
clockwise.
1. Feed 3-circuit ( Three-phase four-wire)
The circuit diagram is shown in figure A
The circuit diagram is shown in figure B
3-Circuit Recessed Flanged Track System
Model: WT1M/2M/3M-RT-2
Option B: Feed from the track pathway.
MAXIMUM LOAD
The drawings below show the maximum permissible mechanical load by W tracks for luminaires or other
loads in relationship to the fixation or suspension point. It includes both of the weights of the track system.
WIRING OPTIONS

INSTALLATION INSTRUCTIONS
Headquarters
44 Harbor Park Drive, Port Washington, NY
Phone (516) 515.5000 • Fax (516) 515.5050
www.waclighting.com
WAC Lighting (Shanghai)
14 Lane 299, Bi Sheng Road Shanghai 201204
Phone (86.21) 3393.3558 • Fax (86.21) 3362.1598
www.waclighting.com.cn
WAC Lighting - International sales
Room 3207-3208, Building 4,Tian An Cloud Park,
ShenZhen, Guangdong 518129
www.waclighting.io
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. April 22, 2019
5 / 6
L2
L3
L1
L2
L1
L3
N
N
L3
L3
L1
L2
N
L2
N
L1
L1
N
L2
N
L2
L1
L3
L3
N
L2
L1
L3
Ground wire is on the left.
Ground wire is on the right.
Ground wire is on inside.
Ground wire is on outside.
3-Circuit Recessed Flanged Track System
Model: WT1M/2M/3M-RT-2
CONNECTOR POLARITY INDICATOR

INSTALLATION INSTRUCTIONS
Headquarters
44 Harbor Park Drive, Port Washington, NY
Phone (516) 515.5000 • Fax (516) 515.5050
www.waclighting.com
WAC Lighting (Shanghai)
14 Lane 299, Bi Sheng Road Shanghai 201204
Phone (86.21) 3393.3558 • Fax (86.21) 3362.1598
www.waclighting.com.cn
WAC Lighting - International sales
Room 3207-3208, Building 4,Tian An Cloud Park,
ShenZhen, Guangdong 518129
www.waclighting.io
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. April 22, 2019
6 / 6
3-Circuit Recessed Flanged Track System
Model: WT1M/2M/3M-RT-2
Warning! Risk of electric shock!
• Before carrying out maintenance and installation, disconnect the mains cables and ensure that all power is
switched off.
• It is the installer’s responsibility to ensure electrical, mechanical and thermal compatibility between the
track system and the luminaires installed on it.
• When installing, always observe the national installation and accident preventionregulations.
• End Caps (WEC-RT-2) should be inserted into the track and secured.