To reduce the risk of re, electric shock or injury to persons:
• Always turn o power at main switch prior to installation.
• System intended for installation by a qualied electrician, in accordance with NEC and local regulations.
Consult with local inspector to assure compliance.
• For use with LED loads.
ModelLD-700MA03-EDIM-IS
Input Voltage120V ac,60Hz
Input CurrentMax 0.04A
OUTPUT CURRENT700mA
Port Output Voltage2-4V DC
Port Load1PC 1x3W LED Fixtures
Port Load Lead Wires12-22AWG
Output Port1 PCS
FEATURES:
• 700mA constant current for LED’s optimized and stable performance.
• Capable of supplying power to a single LED xture.
• Special circuit design to protect LED from high voltage pulse. driver will automatically shut o if the xtures
are not properly wired. In this event, unplug and check the wiring and then plug it in again.
• For use with ELV dimmer.
INSTALLATION:
1. Loosen two cover screws and remove the cover. Inside there one sets of wiring terminals.
2. Push down one set of the wiring terminals and insert xture’s red wire into the “+” terminal and the black wire into
the “-” terminal.
3. After connecting all the LED xtures, secure the cover by tightening the two screws.
4. The product should be installed on the either internal or external surface of any indoor construction.
To reduce the risk of re, electric shock or injury to persons:
• Always turn o power at main switch prior to installation.
• System intended for installation by a qualied electrician, in accordance with NEC and local regulations.
Consult with local inspector to assure compliance.
• For use with LED loads.
ModelLD-700MA09-EDIM-IS
Input Voltage120Vac,60Hz
Input CurrentMax 0.1A
Output Current700mA
Each Port Output Voltage2-4V DC
Each Port Load1-3PCS 1x3W LED Fixtures
Each Port Load Lead Wires12-22AWG
Output Port3 PCS
FEATURES:
• 700mA Constant Current for LED’s optimized and stable performance.
• Capable of supplying power to a single LED xture, or more LED xtures at once.
• Special circuit design to protect LED from high voltage pulse. Driver will automatically shut o if the xtures are
not properly wired. In this event, unplug and check the wiring and then plug it in again.
• For use with ELV dimmer.
INSTALLATION:
1. Loosen two cover screws and remove the cover. Inside there four separate sets of wiring terminals.
2. Push down one set of the wiring terminals and insert xture’s red wire into the “+” terminal and the black wire into
the “-” terminal.
3. After connecting all the LED xtures, secure the cover by tightening the two screws.
4. The product should be installed on the either internal or external surface of any indoor construction.