Wacker Neuson GV 2500A Operator's Manual

0157385en 004 0908
Generator
GV 2500A
OPERATOR’S MANUAL
0157385EN
CARBON MONOXIDE
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide (CO). This is a poison you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even if you cannot smell the exhaust, you could be breathing CO.
NEVER use a generator inside homes, garages, crawlspaces, or other partly enclosed areas. Deadly levels of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does NOT supply enough fresh air.
ONLY use a generator outside and far away from windows, doors, and vents. These openings can pull in generator exhaust.
Even when you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. See a doctor. You could have carbon monoxide poison.
GV 2500A Table of Contents
1. Foreword 5
2. Safety Information 6
2.1 Operating Safety .................................................................................. 7
2.2 Operator Safety while using Internal Combustion Engines .................. 8
2.3 Service Safety ...................................................................................... 9
2.4 Label Locations .................................................................................. 10
2.5 Safety and Operating Labels .............................................................. 11
3. Operation 13
3.1 Determining Power Requirements ..................................................... 13
3.2 Installation .......................................................................................... 15
3.3 Generator Derating ............................................................................. 16
3.4 Grounding the Generator ................................................................... 17
3.5 Operating Heavy Loads ...................................................................... 17
3.6 Use of Extension Cords ...................................................................... 18
3.7 Control Panel ...................................................................................... 20
3.8 Before Starting ................................................................................... 21
3.9 To Start ............................................................................................... 22
3.10 To Stop ............................................................................................... 22
4. Maintenance 23
4.1 Engine Maintenance ........................................................................... 23
4.2 Periodic Maintenance Schedule ......................................................... 23
4.3 Engine Oil ........................................................................................... 24
4.4 Air Cleaner ......................................................................................... 25
4.5 Spark Plug .......................................................................................... 26
4.6 Engine Speed ..................................................................................... 27
4.7 Carburetor Adjustment ....................................................................... 28
4.8 Storage ............................................................................................... 29
4.9 Transport ............................................................................................ 29
4.10 Troubleshooting .................................................................................. 30
4.11 Wiring Diagram ................................................................................... 31
wc_bo0157385en_004TOC.fm 3
Table of Contents GV 2500A
5. Technical Data 32
5.1 Generator ............................................................................................32
5.2 Engine .................................................................................................33
5.3 Sound Specifications ...........................................................................33
wc_bo0157385en_004TOC.fm 4
1. Foreword
Foreword
This manual provides information and procedures to safely operate and maintain this Wacker Neuson model. For your own safety and protection from injury, carefully read, understand and observe the safety instructions described in this manual.
Keep this manual or a copy of it with the machine. If you lose this manual or need an additional copy, please contact Wacker Neuson Corporation. This machine is built with user safety in mind; however, it can present hazards if improperly operated and serviced. Follow operating instructions carefully! If you have questions about operating or servicing this equipment, please contact Wacker Neuson Corporation.
The information contained in this manual was based on machines in production at the time of publication. Wacker Neuson Corporation reserves the right to change any portion of this information without notice.
All rights, especially copying and distribution rights, are reserved.
Copyright 2008 by Wacker Neuson Corporation.
No part of this publication may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission from Wacker Neuson Corporation.
Any type of reproduction or distribution not authorized by Wacker Neuson Corporation represents an infringement of valid copyrights and will be prosecuted. We expressly reserve the right to make technical modifications, even without due notice, which aim at improving our machines or their safety standards.
wc_si000106gb.fm 5
Safety Information GV 2500A
2. Safety Information
This manual contains DANGER, WARNING, CAUTION, NOTICE and NOTE callouts which must be followed to reduce the possibility of personal injury, damage to the equipment, or improper service.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
DANGER
WARNING
CAUTION
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Used without the safety alert symbol, NOTICE indicates a situation which, if not avoided, could result in property damage.
Note: Contains additional information important to a procedure.
wc_si000106gb.fm 6
GV 2500A Safety Information
2.1 Operating Safety
BACKFEED FROM THE GENERATOR INTO THE PUBLIC POWER DISTRIBUTION SYSTEM CAN CAUSE SERIOUS INJURY OR DEATH TO UTILITY WORKERS!
DANGER
WARNING
Improper connection of generator to a building’s electrical system can allow electrical current from the generator to backfeed into utility lines. This may result in electrocution of utility workers, fire, or explosion. Connections to a building’s electrical system must be made by a qualified electrician and comply with all applicable laws and electrical codes.
If connected to a building’s electrical system the generator must meet the power, voltage, and frequency requirements of the equipment in the building. Differences in power, voltage, and frequency requirements may exist and improper connection may lead to equipment damage, fire, and personal injury or death.
Familiarity and proper training are required for the safe operation of the machine. Machines operated improperly or by untrained personnel can be dangerous. Read the operating instructions contained in both this manual and the engine manual and familiarize yourself with the location and proper use of all controls. Inexperienced operators should receive instruction from someone familiar with the machine before being allowed to operate it.
2.1.1 NEVER operate the generator when open containers of fuel, paint, or other flammable liquids are near.
2.1.2 NEVER operate the generator, or tools attached to the generator, with wet hands.
2.1.3 NEVER use worn electrical cords. Severe electrical shock and equipment damage may result.
2.1.4 NEVER run the electrical cords under the generator, or over vibrating or hot parts.
2.1.5 NEVER enclose or cover the generator when it is in use or when it is hot.
2.1.6 NEVER overload the generator. The total amperage of the tools and equipment attached to the generator must not exceed the load rating of the generator.
2.1.7 NEVER operate the machine in snow, rain, or standing water.
2.1.8 NEVER allow untrained personnel to operate or service the generator. The generator set should be set up by a certified electrician.
2.1.9 ALWAYS store the machine properly when it is not being used. The machine should be stored in a clean, dry location out of the reach of children.
wc_si000106gb.fm 7
Safety Information GV 2500A
2.1.10 ALWAYS be sure the machine is on a firm, level surface and will not tip, roll, slide, or fall while operating.
2.1.11 ALWAYS transport the generator in an upright position.
2.1.12 ALWAYS keep the machine at least one meter (three feet) away from structures, buildings, and other equipment during use.
2.1.13 ALWAYS keep the area immediately surrounding and underneath the machine clean, neat, and free of debris and combustible materials. Make sure that the area overhead is clear of debris that could fall onto or into the machine or exhaust compartment.
2.1.14 ALWAYS remove all tools, cords, and other loose items from the generator before starting it.
2.1.15 DO NOT ground this generator.
2.2 Operator Safety while using Internal Combustion Engines
Internal combustion engines present special hazards during operation and fueling. Read and follow the warning instructions in the engine owner’s manual and the safety guidelines below. Failure to follow the
DANGER
warnings and safety standards could result in severe injury or death. NEVER install a generator in an enclosed area such as a tunnel or a
trench. Using a generator in a tunnel or a trench CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a
DANGERDANGER
poison you cannot see or smell. NEVER use this generator inside a tunnel or a trench.
2.2.1 DO NOT smoke while operating the machine.
2.2.2 DO NOT smoke when refueling the engine.
2.2.3 DO NOT refuel a hot or running engine.
2.2.4 DO NOT refuel the engine near an open flame.
2.2.5 DO NOT spill fuel when refueling the engine.
2.2.6 DO NOT run the engine near open flames.
2.2.7 DO NOT start the engine if fuel has spilled or a fuel odor is present. Move the generator away from the spill and wipe the generator dry before starting.
2.2.8 ALWAYS refill the fuel tank in a well-ventilated area.
2.2.9 ALWAYS replace the fuel tank cap after refueling.
2.2.10 ALWAYS check the fuel lines and the fuel tank for leaks and cracks before starting the engine. Do not run the machine if fuel leaks are present or the fuel lines are loose.
wc_si000106gb.fm 8
GV 2500A Safety Information
2.3 Service Safety
Poorly maintained equipment can become a safety hazard! In order for the equipment to operate safely and properly over a long period of time, periodic maintenance and occasional repairs are necessary. If
WARNING
2.3.1 DO NOT use gasoline or other types of fuels or flammable solvents to
2.3.2 DO NOT attempt to clean or service the machine while it is running.
2.3.3 DO NOT modify the machine without the express written approval of
2.3.4 DO NOT allow water to accumulate around the base of the machine.
the generator is experiencing problems or is being serviced, attach a “DO NOT START” sign to the control panel to notify other people of its condition.
clean parts, especially in enclosed areas. Fumes from fuels and solvents can become explosive.
the manufacturer.
If water is present, move the machine and allow the machine to dry before servicing.
2.3.5 DO NOT service the machine if your clothing or skin is wet.
2.3.6 DO NOT allow untrained personnel to service this equipment. Only trained electrical technicians should be allowed to service the electrical components of this equipment.
2.3.7 ALWAYS keep the machine clean and labels legible. Replace all missing and hard-to-read labels. Labels provide important operating instructions and warn of dangers and hazards.
2.3.8 ALWAYS replace the safety devices and guards after repairs and maintenance.
2.3.9 ALWAYS let the engine cool before transporting or servicing it.
2.3.10 ALWAYS keep hands, feet, and loose clothing away from the moving parts on the generator and engine.
2.3.11 ALWAYS turn the engine off before servicing the machine. If the engine has electric start, disconnect the negative terminal on the battery before servicing the machine.
2.3.12 ALWAYS keep the fuel lines in good condition and properly connected. Leaking fuel and fumes are extremely explosive.
wc_si000106gb.fm 9
Safety Information GV 2500A
2.4 Label Locations
ISSINCI
GASOLINA
PETROL
DANGER
GEFAHR
PELIGRO
DANGER
BENZIN
HOT !
CHAUD !
HEISS !
CALDO !
wc_gr001289
wc_si000106gb.fm 10
GV 2500A Safety Information
2.5 Safety and Operating Labels
Wacker Neuson machines use international pictorial labels where needed. These labels are described below:
Label Meaning
WARNING!
HOT !
CHAUD !
HEISS !
CALDO !
Hot surface!
Close the choke.
GASOLINA
PETROL
BENZIN
ISSINCI
Gasoline
Potential Earth.
WARNING! Electric shock will cause serious injury or death.
WARNING! Electric shock hazard. Read Operator’s Man­ual for instructions.
wc_si000106gb.fm 11
Loading...
+ 25 hidden pages