WACKER Group 0008494, 0008495, 0008631, IRFUN 45/115, 0008722 Operator's Manual

...
www.wackergroup.com
Operator's manual
Internal vibrator frequency converter
IRFUN
0203511en 003
01.2007
Foreword
1. Foreword
For your own safety and protection from bodily injuries, carefully read, understand and follow the safety information in this manual.
Please operate and maintain your Wacker machine in accordance with the instructions in this operator's manual. Your Wacker machine will re­ward you with troublefree operation and a high degree of availability.
Defective components must be replaced immediately.
All rights, especially the right for copying and distribution, are reserved
Copyright 2007 by Wacker Construction Equipment AG
No part of this publication may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without ex­press permission in writing from Wacker Construction Equipment AG.
Any type of reproduction, distribution or saving on data carriers of any type or method not authorized by Wacker represents an infringement of valid copyrights and will be prosecuted. We expressly reserve the right to make technical modifications - even without special notice - which aim at further improving our machines or their safety standards.
Table of contents
1. Foreword 3
2. Safety information 5
2.1 General instructions ..............................................................................5
2.2 Operation ...............................................................................................5
2.3 Safety checks ........................................................................................6
2.4 Maintenance ..........................................................................................7
2.5 Transport ...............................................................................................8
2.6 Maintenance checks ..............................................................................8
3. Technical data 9
4. Description 17
4.1 Application ...........................................................................................17
4.2 Functional description .........................................................................17
5. Operation 18
5.1 Starting up ...........................................................................................18
5.2 Connection using separate extension cable ........................................19
5.3 Switching off the machine ...................................................................20
6. Description/maintenance 21
6.1 Protection against overheating ............................................................21
6.2 Maintenance schedule ........................................................................21
6.3 Disassembly and assembly .................................................................21
6.4 Maintenance ........................................................................................22
7. Repair instructions 23
7.1 Repair instructions, faults ....................................................................23
8. Wear dimensions 26
9. Disposal 27
9.1 Environmentally friendly recycling .......................................................27
EC Declaration of Conformity 29
DIN EN ISO 9001 Certificate 31
SV00043en.fm 5
Internal vibrators Safety information
2. Safety information for internal vibrators with integrated frequency converter
2.1 General instructions
2.1.1 The IRFUN may only be worked on independently by persons who
are at least 18 years of age, are physically and mentally fit for this job, have been instructed in operating IRFUN and have proved their ability
for the job to the employer and
may be expected to carry out the job they are charged with carefully.
They must have been assigned to work on the IRFUN by the employer.
2.1.2 IRFUN is to be applied only for compacting work. Both the manufactur-
er's operator's manual and this safety information must be observed. The machine must be immersed in the mass to be compressed.
2.1.3 The persons charged with the operation of IRFUN must be made fa-
miliar with the necessary safety measures relating to the machine. In case of extraordinary uses, the employer shall give the necessary ad­ditional instructions.
2.1.4 Observe the accident prevention regulations set forth by the profes-
sional association for electrical equipment and material and use them as a basis during all work performed with this machine.
2.2 Operation
2.2.1 Make sure that IRFUN with electric motor drive is only attached to the
voltage and frequency indicated on the nameplate. The nameplate is located on the inside of the switch box cover. The voltage to which the machine must be connected is also embossed on the switch housing. Choose correct cross section for extension cord.
2.2.2 IRFUN may only be connected to electric power supplies with a fault
current protective switch. Either fault current protective switches of universal sensitivity must be used or it must be ensured that the IRFUN is connected on its own without any other consumers to an fault current protective switch de­signed for non-sinusoidal current consumption. When connecting the IRFUN to public mains networks, sockets with 15 A fuse must be used.
Safety information Internal vibrators
SV00043en.fm 6
2.2.3 The machine corresponds to class rating 1 (grounded conductor).
2.2.4 Prior to starting IRFUN, make sure that the components are screwed
on securely.
2.2.5 Do not insert or pull out the power plug as a means of turning IRFUN
on or off.
2.2.6 The power cable of IRFUN must not be used to pull out the plug from
the plug receptacle.
2.2.7 Protect electric cable from heat, oil, and sharp edges.
2.2.8 Electrical equipment and material may only be used if they comply with
operational and local safety requirements. They must be in proper con­dition and this condition is to be maintained.
2.2.9 Activated IRFUNs should not come into contact with any solid objects
over a long period of time, long running times in the air must be avoid­ed.
2.2.10 When taking a break or when leaving IRFUN, the operator must switch
off the machine and park it securely in such a way to ensure that it can­not tip over or fall down.
2.2.11 Do not operate IRFUN in areas where explosions may occur.
2.2.12 Appropriate protective gloves must always be worn when handling
IRFUN. Do not touch the hot vibrator head.
2.2.13 The protective hose must be used to guide the machine during opera-
tion. Using the vibrator head to guide the IRFUN can cause vascular diseases.
2.2.14 The transmission of vibration oscillations to the material to be com-
pacted can damage or destroy the casing. Casings must be secured according to regulations before using the machine.
2.3 Safety checks
2.3.1 Before starting operation, the operator has to check that all control and
safety devices are functioning properly.
2.3.2 Prior to connecting the machine, check the electric cable and socket
for damage on a regular basis.
SV00043en.fm 7
Internal vibrators Safety information
2.3.3 Also check the proper functioning of the On/Off switch and the fault
current protective switch.
2.3.4 If defects on the safety devices or other defects impairing the opera-
tional safety of internal vibrators are observed, the supervisor must be informed immediately. The machine must not be commissioned.
2.3.5 If there are defects jeopardizing operational safety, the machine has to
be switched off immediately.
2.3.6 Check the bottom part of the pipe for cracks, damage or loose screw
connections. The vibration cylinders are not suitable for use if the bot­tom part of the pipe is missing.
2.3.7 Check the clamps on the connections.
2.3.8 The machine can start to run immediately as soon as it is connected to
the mains depending on the switch setting. This is also possible if the switch is defective.
2.4 Maintenance
2.4.1 IRFUN must only be opened and repaired by qualified and authorized
personnel.
2.4.2 Only use original spare parts. Alterations to this machine, incl. adjust-
ments of the maximum engine speed set by the manufacturer may only be carried out with the express permission of WACKER. In case of non-observance, all liability shall be refused.
2.4.3 Disconnect IRFUN from the electrical power supply system by pulling
out the mains plug before carrying out maintenance and repair work.
2.4.4 Work on the electric parts of the machine may only be carried out by
skilled technicians.
2.4.5 The green-yellow grounded conductor must be longer than the current-
carrying conductors, so that it does not tear off first should the strain relief fail. If interrupted, it can cause fatal injury. After conducting re­pairs, check the grounded conductor for continuity.
2.4.6 As soon as maintenance and repair jobs have been completed, all
safety devices must be properly reinstalled. Screws must be tightened according to the tightening torques specified in the standards.
2.4.7 Clean IRFUN daily. Make sure not to damage the lines when using
high pressure washers.
Safety information Internal vibrators
SV00043en.fm 8
2.5 Transport
2.5.1 Secure IRFUN against falling down during transportation.
2.6 Maintenance checks
2.6.1 According to the conditions and frequency of use, IRFUN must be
checked for safe operation by a technician, for example at a WACKER service station, at least once every 6 months and repaired if neces­sary.
Please observe the appropriate rules and regulations valid in your coun­try.
TD00701en.fm 9
Technical data
3. Technical data
IRFUN 38/115 IRFUN 45/115
Item no.
8 m
8 m GV
10 m
10 m GV
0008494 0008631
0008495 0008722 0008769 0008771 0008770 0008772
0008496 0008630
0008497 0008723 0008773 0008775 0008774 0008776
Vibrator head
Integrated three-phase AC motor
kW:
0.41 0.47 0.58 0.68
Voltage
V:
214 3~
Frequency
Hz:
200
Rated current
A:
1.6 2.3
Vibrations
rpm:
12000
Vibrator diameter
mm (in):
38 (1.5) 45 (1.8)
Vibrator length
mm (in):
345 (13.6) 382 (15)
Vibrator weight (mass) (without hose connection)
kg (lb):
2.2 (4.85) 3.5 (7.72)
Effective diameter in concrete
cm (ft):
up to:
50 (1.6) 60 (2.0)
Oil type
SAE 0W-30
Oil quantity
cm
3
(in3):
8 (0.49)
Inverter / mains connection value
Alternating current V:
110 - 130 1~
Frequency Hz:
50 / 60
Current A:
68
Power kVA:
kW:
0.72
0.85
0.69
0.55
0.96
0.74
0.92
0.74
Technical data
TD00701en.fm 10
Sound pressure level LpA at operator's station
dB(A):
79
The weighted effective acceleration value, determined according to EN ISO 5349
m/s
2
:
2.5
These noise and vibration figures were calculated with the internal vibrator being freely suspended in air at the nominal speed of the drive motor.
IRFUN 38/115 IRFUN 45/115
TD00701en.fm 11
Technical data
IRFUN 57/115 IRFUN 57k/115
Item no.
8 m
8 m GV
10 m
10 m GV
0008481 0008482 0008628 0008724
0008928, 0008777
0008779 0008778 0008780
0008629
Vibrator head
Integrated three-phase AC motor
kW:
1.04 0.76
Voltage
V:
214 3~
Frequency
Hz:
200
Rated current
A:
3.5 2.6
Vibrations
rpm:
12000
Vibrator diameter
mm (in):
58 (2.3)
Vibrator length
mm (in):
400 (15.7)
Vibrator weight (mass) (without hose connection)
kg (lb):
5.8 (12.79) 4.8 (10.59)
Oil type
SAE 0W-30
Oil quantity
cm
3
(in3):
12 (0.73)
Inverter / mains connection value
Alternating current V:
110 - 130 1~
Frequency Hz:
50 / 60
Current A:
12
Power kVA:
kW:
1.38
1.1
1.38
0.92
Loading...