V-ZUG 55-381, V400 Installation Instructions Manual

Installation instructions
J24001113-R02
Microwave Type of construction 55-381
Validity
These installation instructions apply to the models:
24001, 24003
General notes
If installing into a combustible material, the guidelines and standards for low voltage installations and fire protection must be strictly observed.
Identification plate
Open the appliance door.
– The identification plate is located on the left-hand side of the cooking space.
Dimensions
External dimensions (H×W×D): 378 × 548 × 320 mm Cooking space dimensions (H×W×D): 187 × 370 × 290mm
J24001113-R02
10/04/2018
Electrical connections
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards for low-voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa­tions.
The appliance is designed for use up to a max. altitude of 2000 m above sea level.Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
The mains plug must not be cut off.
Installation
Minimum installation height: Observe distance of 850mm between floor and bottom edge of microwave!
Notes
The appliance must not be installed directly over a cooking area.
Supply air must be guaranteed at all times.
When installing in a tall unit, a ventilation cross-section of at least 110cm² must be guaranteed.
1
Installation instructions
J24001113-R02
2050 *
=
=
M
550
381
762
B
548
378
320
330
S2
530
90°
M
210
40
S1
S1
30
S3
W1
S2
C
30
Microwave Type of construction 55-381
Installation in wall unit
J24001113-R02
10/04/2018
* from the floor
1. Produce 2 holes on the left and right in the niche walls for chipboard screws S1.
2. Screw assembly kit M on the left and right with the S1 screws provided.
3. Plug connection cable B into power socket. Slide appliance on assembly kit M into niche with around 5 cm protruding.
4. Secure retaining strap W1 on left and right onto appliance from below with S3 screws (zinc-plated).
5. Slide appliance on assembly kit M flush into niche.
6. Secure appliance on left and right with S2 screws (white).
7. Guide stop bracket C (adjustable: 320–350mm) up to wall, then tighten.
2
Installation instructions
J24001113-R02
M
548
320
567
605
550
≥110 cm
2
≥20
759 378
1143
381
S1
B
S2
M
567
548
320
605
550
≥ 110 cm
2
≥ 20
598 378
981 *
381
S2
B
S1
S3
W1
S2
≥ 20
≥ 20
≥ 20
G G
D E
F
G
Microwave Type of construction 55-381
Installation in tall unit
J24001113-R02
10/04/2018
Microwave & oven
Oven with drawer
Microwave & oven
Oven without drawer
* If adjustment to niche height of 1016mm is needed, use additional height adapter 35mm (see J715.050)
1. Produce 2 holes on the left and right in the niche walls for chipboard screws S1.
2. Screw assembly kit M on the left and right with the S1 screws provided.
3. Plug connection cable B into power socket. Slide appliance on assembly kit M into niche with around 5cm protruding.
4. Secure retaining strap W1 on left and right onto appliance from below with S3 screws (zinc-plated).
5. Slide appliance on assembly kit M flush into niche.
6. Secure appliance on left and right with S2 screws (white).
D Normal oven / tall unit E Oven / extractor oven F Aluminium flexible hose well stretched G Ventilation cross-section of at least
110cm²
Standalone installation Installation above
normal oven
Installation above
extractor oven
3