IMPORTANT SAFETY INSTRUCTIONS
Basic safety precautions should always be followed; including the following:
♠ Read and understand all instructions before proceeding with the installation and operations.
♠ Lectric IIe and Lectric IVe meet requirement for fire-resistant and low smoke-producing
characteristics suitable for operation in a build ing’s environmental air space, such as above
suspended ceilings, in accordance with Section 300-22 (C) of the national Electric Code,
ANSI/NFPA 70, and sections 2-128, 12-010(3) and 12-100 of the Canadian Electric Code, Part 1,
CSAC22.1.
♠ Be certain that the supporting structure is sound and capable of carrying the weight as required.
♠ Seek qualified electricians to perform electrical requirements.
♠ This permanently connected projection screen must be protected by a fuse or circuit breaker.
Make sure that there is a readily disconnect devi ce incorporated on the building installation
wiring.
♠ Obtain proper lifting mechanism to raise and hold the unit steady for installation.
♠ Plan ahead so the installation can go smoothly and efficiently.
IMPORTANT WARNINGS AND CAUTIONS!
WARNING: A WARNING ALERTS THE POSSIBILITY OF SERIOUS INJURY OR DEATH IF THE INSTRUCTIONS ARE NOT FOLLOWED.
CAUTION: A CAUTION ALERTS THE PO SSIBILITY OF DAMAGE OR DESTRUCTION OF EQUIPMENT IF THE INSTRUCTIONS ARE NOT
FOLLOWED.
WARNING: FA ILURE TO REA D, TH OROUGHLY UN DERSTAND, AND FO LLOW AL L INSTRUC TIONS C AN RESUL T IN SERIOUS
PERSONAL INJURY, DAMAGE TO EQUIPMENT, OR VOIDING OF FA CTORY WA RRANTY! IT IS TH E IN STALLER’S
RESPONSIBILITY TO MAKE SURE ALL COMPONENTS ARE PR OPERLY ASSEMBLED AND INSTALLED USING THE
INSTRUCTIONS PROVIDED.
WARNING: FAIL URE TO INSTA LL EL ECTRICAL REQ UIREMENTS AC CORDING TO NATIO NAL/LOCAL EL ECTRICAL CODES AND
REGULATIONS MAY CAUSE PREMATURE FAILURE, FIRE HAZARD, ELECTRICAL SHOCK, UNSAFE PRACTICE AND
REVOCATION OF USE.
DISCLAIMER
Vutec Corporation intends to m ake this m anual accurate and com plete. However, Vutec m akes no claim that the
information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency
in connection with the installation for use of t his product. The information contained in this document is subject to change
without not ice. Vut ec m akes no representation of warranty, expressed or i mplied, regardi ng t he information contained
herein. Vutec assum es no responsibility for accuracy, completeness or sufficiency of the info rmation contained in this
document.
PRE- INSTALLATION
1) Carefully cut and remove packing materials.
2) Carefully unpack and inspect the unit for sign of damages.
3) Be sure to recheck and measure all pertinent dimensions before installation.
4) Most basic tools are required for installation.
SAVE THESE INSTRUCTIONS
LIIe-INST_D
04/21/08 Rev D
![](/html/83/8351/83514a69046016aa77cd77b8f884f38f3691bcb462e509ad73b5261c9e3b7b48/bg3.png)
2
LECTRIC IIe & IVe
FLUSH CEILING MOUNT WITH TRAP DOOR
SELF-SUPPORTED (shown) and TAB-TENSIONED screens
Figure 1
SCREEN TYPE LENGTH DIM. A
SELF-SUPPORTED VIEWING WIDTH + 15 1/2 7 3/4
TAB-TENSIONED VIEWING WIDTH + 22 1/2 11 1/4
LIIe-INST_D
04/21/08 Rev D
![](/html/83/8351/83514a69046016aa77cd77b8f884f38f3691bcb462e509ad73b5261c9e3b7b48/bg4.png)
3
HOUSING INSTALLATION Lectric IIe (Self-supporting fabric) and Lectric IVe (Tab-tensioned fabric) are
designed for flush ceiling mount. These units are suitable for use in environmental air space in accordance with
Section 300-22 (C) of the National Electric Code, ANSI/NFPA 70, and Sections 2-128, 12-010(3) and 12-100 of
the Canadian Electric Code, Part 1, CSAC22.1. As shown in Figure 2a, Opti on 1 is the preferred m ounting
method which requires access space above the ceiling. The m ounting brackets m ay be placed any where along
the housing length as desired. However, it is best to even ly space them for uniform weight distribution. It is
recommended the end m ounting brackets should not be m ore than 4 inches from each end of housing. The
housing has a built-in trim flange around the bottom. Ceiling tiles or drywall may be placed on top of this flange
to provide a finished appearance.
WARNING: SUPPORTING STRUCTURE MUST BE CAPABLE OF CARRYING 4 TIMES THE UNIT WEIGHT. CHECK WEIGHT DATA AT THE
END OF THIS DOCUMENT.
Threaded rods of 3/8 (10mm) diameter, hex nuts and helical lock washers are to be provided by installers.
After securing the housing in the ceiling check that th e housing is level and plum b. Make adjustm ents as
necessary then tighten the hex nuts.
It is recommended that safety cables be added to the housing for additional safety concern. The cables may be
looped and tied to end mounting brackets between the housing and bracket (Figure 2c).
Figure 2b
Some Parts Removed
For Illustration
Figure 2a
Option 1 - Suspended Mounting
An alternate m ounting method is available as shown in Figure 3. This m ounting option m ust be requested in
advance at the time of order placement for the mounting holes to be drilled.
It is the installer responsibility to supply proper mounting hardware for option 2 mounting.
Option 2 mounting requires the screen roller assembly to be removed to gain clearance for the m ounting screws
along the middle section of the housing.