Vutec LECTRIC II Installation Instructions

Installation Instructions
Lectric IIe & IVe
FLUSH CEILING MOUNT SCREEN FULL TRAP DOOR CLOSURE
VIDEO PROJECTION SCREENS
02/20/08 Rev. D LIIe-INSTL_D
1
IMPORTANT SAFETY INSTRUCTIONS
Basic safety precautions should always be followed; including the following:
Read and understand all instructions before proceeding with the installation and operations. Lectric IIe and Lectric IVe meet requirement for fire-resistant and low smoke-producing
characteristics suitable for operation in a building’s environmental air space, such as above suspended ceilings, in accordance with Section 300-22 (C) of the national Electric Code, ANSI/NFPA 70, and sections 2-128, 12-010(3) and 12-100 of the Canadian Electric Code, Part 1, CSAC22.1.
Be certain that the supporting structure is sound and capable of carrying the weight as required. Seek qualified electricians to perform electrical requirements. This permanently connected projection screen must be protected by a fuse or circuit breaker.
Make sure that there is a readily disconnect device incorporated on the building installation wiring.
Obtain proper lifting mechanism to raise and hold the unit steady for installation. Plan ahead so the installation can go smoothly and efficiently.
IMPORTANT WARNINGS AND CAUTIONS!
WARNING: A WARNING ALERTS THE POSSIBILITY OF SERIOUS INJURY OR DEATH IF THE INSTRUCTIONS ARE NOT FOLLOWED.
CAUTION: A CAUTION ALERTS THE POSSIBILITY OF DAMAGE OR DESTRUCTION OF EQUIPMENT IF THE INSTRUCTIONS ARE NOT
FOLLOWED.
WARNING: FAILURE TO READ, THOROUGHLY UNDERSTAND, AND FOLLOW ALL INSTRUCTIONS CAN RESULT IN SERIOUS
PERSONAL INJURY, DAMAGE TO EQUIPMENT, OR VOIDING OF FACTORY WARRANTY! IT IS THE INSTALLER’S RESPONSIBILITY TO MAKE SURE ALL COMPONENTS ARE PROPERLY ASSEMBLED AND INSTALLED USING THE INSTRUCTIONS PROVIDED.
WARNING: FAILURE TO INSTALL ELECTRICAL REQUIREMENTS ACCORDING TO NATIONAL/LOCAL ELECTRICAL CODES AND
REGULATIONS MAY CAUSE PREMATURE FAILURE, FIRE HAZARD, ELECTRICAL SHOCK, UNSAFE PRACTICE AND REVOCATION OF USE.
DISCLAIMER
Vutec Corporation intends to make this manual accurate and complete. However, Vutec makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation for use of this product. The information contained in this document is subject to change without notice. Vutec makes no representation of warranty, expressed or implied, regarding the information contained herein. Vutec assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document.
PRE- INSTALLATION
1) Carefully cut and remove packing materials.
2) Carefully unpack and inspect the unit for sign of damages.
3) Be sure to recheck and measure all pertinent dimensions before installation.
4) Most basic tools are required for installation.
SAVE THESE INSTRUCTIONS
LIIe-INST_D
04/21/08 Rev D
2
LECTRIC IIe & IVe
FLUSH CEILING MOUNT WITH TRAP DOOR
SELF-SUPPORTED (shown) and TAB-TENSIONED screens
Figure 1
SCREEN TYPE LENGTH DIM. A
SELF-SUPPORTED VIEWING WIDTH + 15 1/2 7 3/4
TAB-TENSIONED VIEWING WIDTH + 22 1/2 11 1/4
LIIe-INST_D
04/21/08 Rev D
3
HOUSING INSTALLATION Lectric IIe (Self-supporting fabric) and Lectric IVe (Tab-tensioned fabric) are
designed for flush ceiling mount. These units are suitable for use in environmental air space in accordance with Section 300-22 (C) of the National Electric Code, ANSI/NFPA 70, and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electric Code, Part 1, CSAC22.1. As shown in Figure 2a, Option 1 is the preferred mounting
method which requires access space above the ceiling. The mounting brackets may be placed anywhere along the housing length as desired. However, it is best to evenly space them for uniform weight distribution. It is recommended the end mounting brackets should not be more than 4 inches from each end of housing. The housing has a built-in trim flange around the bottom. Ceiling tiles or drywall may be placed on top of this flange to provide a finished appearance.
WARNING: SUPPORTING STRUCTURE MUST BE CAPABLE OF CARRYING 4 TIMES THE UNIT WEIGHT. CHECK WEIGHT DATA AT THE
END OF THIS DOCUMENT.
Threaded rods of 3/8 (10mm) diameter, hex nuts and helical lock washers are to be provided by installers. After securing the housing in the ceiling check that the housing is level and plumb. Make adjustments as
necessary then tighten the hex nuts.
It is recommended that safety cables be added to the housing for additional safety concern. The cables may be looped and tied to end mounting brackets between the housing and bracket (Figure 2c).
Figure 2b Some Parts Removed For Illustration
Figure 2a
Option 1 - Suspended Mounting
An alternate mounting method is available as shown in Figure 3. This mounting option must be requested in advance at the time of order placement for the mounting holes to be drilled.
It is the installer responsibility to supply proper mounting hardware for option 2 mounting. Option 2 mounting requires the screen roller assembly to be removed to gain clearance for the mounting screws
along the middle section of the housing.
LIIe-INST_D
04/21/08 Rev D
Loading...
+ 8 hidden pages