Vutec ARTSCREEN Recessed Installation Instructions

Page 1
INSTALLATION INSTRUCTIONS (rev A)
Recessed Mount Plasma
Installation
The Plasma must be in the vertical position for the Art Screen to work properly. Tilting of the Plasma is not recommended.
Review Figures 6 through 7 for a set of possible installation scenarios.
Dry wall installation requires base support as shown in Figure 1. Additional supports to strengthen the base support should also be considered.
Determine ventilation concept for the plasma.
Determine I/O routing of the video/audio cables and AC power supply.
Place the main shell in the wall opening. Be sure the main shell is level; shims as required. Screw the shell to the wall.
Remove the Clamp Bar and the plasma stands.
Install the stands to the plasma. Place the fender washers in the channel to reduce slot size for tightening of the screws.
Figure 1 Wall Construction
Figure 2 Main Shell Assembly
Do not tighten the screws. Place the plasma with the stands inside the main shell. Adjust the bottom rests to center the plasma in the vertical direction.
Bring the plasma and it stands outside of the shell; tighten the screws to secure the plasma to the stands.
Place the plasma back inside the shell. Make all necessary connections, i.e. video/audio cables, AC supply, etc.
Install the Clamp Bar. Do not tighten the screws.
Referring to Figure 4, position the plasma so that the bezel face of the plasma is approximately 1/2 to 5/8 inch behind the shell. This is the clearance required for the Artwork to travel up and down.
The plasma must be centered in the shell on all sides. Verify and adjust as necessary. Tighten the screws of the Clamp Bar to secure its location.
It is wise to test the complete system at this time.
Finish the gaps between the main shell and the wall as
required.
VUTEC CORPORATION
www.vutec.com
TEL: (954) 545 9000 - FAX: (954) 545 9011 E-MAIL:info@vutec.com
Page 2
Wood Frame Installation
A typical wood frame including the liner is approximately 5 inches wide to properly cover the assembly. The wood overhangs the main shell approximately 3/4 inch when attached.
Two corner woods are attached to the backside of the wood frame to take-up the weight.
The wood frame attaches to the main shell by two clips on the backside (see Picture Frame Installation and Removal Section) and hold in place by the ears of the main shell.
Electrical Connections
A dual AC outlet box is provided for 120VAC connection. Connect 120VAC to this box to power the TV and the IR remote control.
The Art Screen comes with IR remote control for operations. It is ready for use; no wiring connections are required.
Place the IR sensor so that it can be seen by the transmitter.
Plug the power cord to a 120VAC outlet.
The IR remote control has manual inputs for Home Automation systems, i.e. AMX, Crestron, etc. See IR remote control manual (included) for detail information.
The SPDT switch (Figure 3b) may be used for security purpose; its contacts may be connected to an audible alarm system or monitoring system. The breach of security will be activated when the wood frame is removed.
The normal states of the contacts are shown when the wood frame is not presented.
Contact Rating: 10Amp, 1/2HP, 125/250VAC or 6Amp, 30VDC.
Fi gure 3a Partial Assembly
Figure 3b SPDT switch
Figure 4 Side View
VUTEC CORPORATION
www.vutec.com
TEL: (954) 545 9000 - FAX: (954) 545 9011 E-MAIL:info@vutec.com
Page 3
Open and Close Limits Setting
The Open limit switch has been properly set for correct stop position. It should not be adjusted unless a change in the motor or the motor had been removed for service.
Note each full turn of the limit switch (360 degrees) causes the screen to travel approximately 1/2 inch.
1. To lower the closed limit of the Art Screen. Send the Art Screen down to it closed position. Turn the Close limit socket
counter-clockwise (Figure 5); the Art Screen will advance downward as each full turn is made. Stop at the desired position.
2. To raise the closed limit of the Art Screen. Send the Art Screen down to it closed position. Determine the number of turns to
stop the screen above the desired close limit. Turn the Close limit socket clockwise to raise the limit. The motor will not move for this direction.
3. Send the screen up halfway then stop. Send the screen down to its closed limit. The screen must stop above the desired position. If
it is not, repeat step 2
4. When the Art Screen stopped above the desired closed limit; do Step 1 to set the desired closed limit.
5. Check and adjust the closed and open limits as necessary.
Figure 5 Motor Limit Switches
VUTEC CORPORATION
www.vutec.com
TEL: (954) 545 9000 - FAX: (954) 545 9011 E-MAIL:info@vutec.com
Page 4
Fi gure 6a Figure 6b Fi gure 6c 40 and 50 inches Diagonal Plasmas
Fi gure 7a Figure 7b Fi gure 7c 60 inches Diagonal Plasma
VUTEC CORPORATION
www.vutec.com
TEL: (954) 545 9000 - FAX: (954) 545 9011 E-MAIL:info@vutec.com
Page 5
Accessories Included
Description QTY.
Frame Assembly including Artwork and Motor 1 Plasma Stand Assembly 2 Clamp Bar 1 Wood Frame (Complete) 1 IR Receiver in Box 1 IR Sensor (6 Feet Long) 1 IR Transmitter 1 AAA Battery 2 #8 x 1 1/2 Long, Truss Head Phillip Screw 10 4mm x 12mm Long Button Head Cap Screw 4 5mm x 12mm Long Button Head Cap Screw 4 6mm x 12mm Long Button Head Cap Screw 4 8mm x 12mm Long Button Head Cap Screw 4 3/16 Dia. Fender Washer 4 1/4 Dia. Fender Washer 8 5/16 Dia. Fender Washer 4
Lim it Switch Setting Tool 1
Figure 8 Complete Art Screen Installation
VUTEC CORPORATION
www.vutec.com
TEL: (954) 545 9000 - FAX: (954) 545 9011 E-MAIL:info@vutec.com
Page 6
PICTURE FRAME INSTALLATION & REMOVAL WITH SLIDING CLIPS
Figure B
Backside of picture frame
Figure A
Installed unit without picture frame
The backside of the picture frame is in full contact with the front edges of the metal frame. Position the two corner woods and clips to be guided by the vertical edges of the metal frame. Carefully pushes down (Figure C2) on the picture frame to set it in place. Corner woods will make slight noise when they are bottom out to the metal frame. Push up picture frame (2 inches approx.) to remove.
A SPDT switch is provided for security connection (optional). Contact rating: 10A, 1/2HP, 125/250VAC or 6A, 30VDC
Figure C3
Figure C1
Frame clip and ear prior to engagement
Figure C2
Picture frame pushes down
Clip fully engaged
VUTEC CORPORATION
www.vutec.com
TEL: (954) 545 9000 - FAX: (954) 545 9011 E-MAIL:info@vutec.com
Page 7
VUTEC CORPORATION
www.vutec.com
TEL: (954) 545 9000 - FAX: (954) 545 9011 E-MAIL:info@vutec.com
Page 8
DISPLAY PANEL REAR VIEW
DISPLAY PANEL WALL INSTALLATION
ASSEMBLY INSTRUCTION (LCD SLIM LINE 1 1/2" PANEL DEPTH)
1. PLACE THE PANEL FACE DOWN ON A CLEANED AND FLAT SURFACE
LINEUP THE CLAMP BAR SLOTS WITH THE MOUNTING HOLES ON REAR OF THE DISPLAY PANEL, ADJUST AS REQUIRED
2. SECURE THE CLAMP TIE BAR (HARDWARE NOT SUPPLIED) DO NOT OVER TIGHTEN
ROTATE THE ASSEMBLY UPRIGHT POSITION AND CHECK FOR PROPER ALIGNMENT AND ADJUST AS NECESSARY.
3. REPLACE EXISTING IEC POWER CORD WITH THE (VUTEC SUPPLIED) NEMA 5-15
ROTATING UNIVERSAL IEC POWER CORD PRIOR TO PROCEEDING TO INSTALL THE LCD DISPLAY
4. THE LCD DISPLAY SHOULD BE EQUALLY SPACED WITHIN THE INTERNAL FRAME PERIMITER
LINEUP THE TIE CLAMP MOUNTING SLOTS WITH THE APPROPRIATE THREADED HOLE AS ILLUSTRATED BELOW AND FASTED WITH USING SUPPLIED HARDWARE.