THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL
GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND
ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE
EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE
OBTAINED FROM THE LOCAL GAS SUPPLIER.
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT THE MAIN
SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER
FOR SERVICE.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS
IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
IMPORTANT FOR YOUR SAFETY
IMPORTANT
FOR YOUR SAFETY
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
VULCAN-HART F-32971 Rev. F (December 2011)
-2-
VK SERIES GAS FRYERS
IMPORTANT FOR YOUR SAFETY………………………………………. 2
INTRODUCTION…………………………………………………………… 4
GENERAL…………………………………………………………… 4
ORDERING PARTS………………………………………………… 4
FRYER CAPACITIES………………………………………………. 4
UNPACKING………………………………………………………… 5
INSTALLATION……………………………………………………………. 5
Clearances………………………………………………….... 5
Location ………………..……………………………….…. 5
OPERATION………………………………………………………………… 10
OVER-TEMPERATURE SHUTDOWN……………………………. 10
BEFORE FIRST USE………………………………………………... 10
Cleaning…………………………………………………….... 10
PROGRAMMING THE SOLID STATE KNOB (A) CONTROL………… 13
PROGRAMMING THE SOLID STATE (D) CONTROL………………… 14
PROGRAMMING THE COMPUTER (C) CONTROL…………………… 15
TURNING OFF THE FRYER ……………………………………. 16
EXTENDED SHUTDOWN……………………………………….. 16
CODES AND STANDARDS……………………………………….. 6
ASSEMBLY …………..…………………………………………… 6
FLUE CONNECTION………………………………………………. 7
ELECTRICAL CONNECTION………………………………………. 7
GAS CONNECTION…………………………………………………. 8
Quick-Disconnect for Units on Casters…………………… 8
GAS PRESSURE......................................................................... 8
TEST GAS SUPPLY………………………………………………… 8
FRYERS WITH CASTERS………………………………………… 8
LEVELING THE FRYER…………………………………………… 9
FILLING TANK WITH SHORTENING…………………………… 10
BASIC FRYING INSTRUCTIONS………………………………….. 11
Fry Basket Guidelines………………………………………. 11
EXTENDED SHORTENING LIFE………………………………… 12
TURNING ON THE FRYER ………………………………………… 12
FILTERING THE OIL……………………………………………. 16
DRAINING THE TANK……………………………….…… 17
FLUE VENT INSPECTION……………………………………….. 28
Service in the US and Canada…………………………………... 28
Alarms and Error Messages…………………………………….. 28
VULCAN-HART F-32971 Rev. F (December 2011)
-3-
VK SERIES GAS FRYERS
Vulcan Fryers are produced with quality workmanship and material. Proper installation,
usage and maintenance will result in years of satisfactory performance.
Before installing the fryer, thoroughly read this manual and carefully follow all instruction.
This manual is applicable to model listed on the cover page. Procedures in this manual
will apply to all models unless specified. Pictures and illustrations can be of any model
unless the picture or illustration needs to be model specific.
Customers may order parts directly from their local authorized service center. If not
known, call Vulcan Customer Service at 800-814-2028.
To speed up your order, provide the model number, serial number, gas type, part needed,
item part number (if known) and quantity needed.
This fryer was carefully inspected before leaving the factory. Upon acceptance of the
shipment, the transportation company assumes full responsibility for safe delivery.
Immediately after unpacking the fryer, check for possible shipping damage. If the fryer is
damaged, save the packaging material and contact the carrier within 15 days of delivery.
Check that the following have been included:
Crumb Rack(s)
Basket Hanger(s)
Tank Brush
Adjustable Casters (4) two locking, two non-locking for freestanding fryers. Fryer
Batteries with the KleenScreen
from the factory.
Drain Pipe Extension for freestanding fryers only.
Twin Fry Baskets (2) per fry tank
Cleanout Rod
Fryer Batteries with the KleenScreen PLUS® Filtration System
Filter Pan
Suction Tube
Screen Assembly
Complimentary Pack of Micro-Filtration Envelopes
High temperature discard hose
Manual, Quick Start Guide(s), and Warranty – Keep in safe place for future
reference.
INTRODUCTION
GENERAL
ORDERING PARTS
UNPACKING
PLUS® Filtration System have casters installed
VULCAN-HART F-32971 Rev. F (December 2011)
-4-
VK SERIES GAS FRYERS
Do not use the door or its handle to lift the fryer.
Before installing the fryer, verify that the type of gas (natural or propane) agrees with the
specifications on the fryer data plate, which is located on the inside of the door panel.
Make sure the fryer is configured for the proper elevation.
Record your fryer model, device, and serial numbers for future reference in the space
provided below. This information can be found on the fryer data plate.
Fryer Model No: ___________________________
Device: ___________________________________
Serial No: ________________________________
Clearances
Minimum clearance from combustible construction:
6” (15 cm) from the sides of the fryer
6” (15 cm) from the back of the fryer
The fryer may be installed on combustible floors
Minimum clearance from noncombustible construction:
0” from the sides of the fryer
0” from the back of the fryer
Between the fryer and any open-top flame units:
16” (41 cm)
Allow space for servicing and operation.
Location
Install fryer in an area with sufficient air supply for gas combustion.
Do not obstruct the flow of combustion and ventilation air.
Provide adequate clearance for air openings into the combustion chamber.
Do not permit fans to blow directly onto fryer.
Keep the fryer area free and clear from combustibles.
Avoid wall-type fans, which create cross-currents within a room. Avoid
open windows next to sides or back.
INSTALLATION
VULCAN-HART F-32971 Rev. F (December 2011)
-5-
VK SERIES GAS FRYERS
CODES AND STANDARDS
The fryer must be installed in accordance with:
In the United States:
State and local codes, or in the absence of local codes, with:
National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may be
obtained from The American Gas Association Accredited Standards Committee
Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards
Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471.
NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy,
MA. 02169-7471.
National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained
from The National Fire Protection Association, Batterymarch Park, Quincy, MA.
02169-7471.
In the commonwealth of Massachusetts all gas appliances vented through a ventilation hood or exhaust system with a damper or with a power means of
exhaust shall comply with 248 CMR.
In Canada:
Local codes
CAN/CSA-B149.1 Natural Gas and Propane Installation Code (latest
edition),available from the Canadian Standards Association, 155 Queen Street,
Suite 1300, Ottawa, Ontario Canada K1P 6L1.
CSA C22.1 Canadian Electric Code (latest edition), available from the Canadian
The fryer must be restrained to prevent tipping and the splashing of hot liquid. The means
of restraint may be the manner of installation, such as connection to a battery of
appliances, installing the fryer in an alcove, or by separate means such as adequate ties.
VULCAN-HART F-32971 Rev. F (December 2011)
-6-
VK SERIES GAS FRYERS
Make the flue connection as follows:
Comply with Vapor Removal from Cooking Equipment, ANSI-NFPA
Standard #96 (latest edition), available from the National Fire Protection
Association, Batterymarch Park, Quincy, MA 02269.
Locate the fryer under a hood with adequate connection to an exhaust
duct. The hood must extend 6” (15 cm) beyond fryer on both sides.
Clearance above the fryer should be adequate for combustion byproducts
to be removed efficiently.
An 18” (46 cm) minimum clearance should be maintained between the flue
vent and the filters of the hood venting system.
Never make flue connections directly to the fryer.
Do not obstruct the flow of the gases from the appliance. Proper air
balance should be maintained in the room.
Ensure that your ventilation system does not cause a down draft at the fryer’s flue
opening. Down drafts will not allow the fryer to exhaust properly and will cause
overheating which may cause permanent damage. Damage caused by down
drafts will not be covered under equipment warranty. NEVER allow anything to
obstruct the flue of combustibles or ventilation exiting from the fryer flue. DO
NOT put anything on top of flue area.
Electrical Grounding Instructions:
This appliance is equipped with a three prong (grounding) plug for your protection against
shock hazard and should be plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from this plug. Fryer must be
electrically grounded in accordance with local codes, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA
C22.2, as applicable.
Electrical diagram located on inside of door.
FLUE CONNECTION
ELECTRICAL CONNECTION
VULCAN-HART F-32971 Rev. F (December 2011)
-7-
VK SERIES GAS FRYERS
All gas supply connections and any pipe joint compound must be
resistant to the action of propane gases.
The gas inlet is located on the lower rear of the fryer. Codes require that a gas shutoff
valve be installed in the gas line ahead of the fryer.
The gas supply line must be at least the equivalent of ½” (12.7 mm) iron pipe for single
units and 1-1/4” (31.75 mm) for batteries. If using the optional quick-disconnect flex hose,
¾” (19 mm) iron pipe for single units and 1-1/4” (31.75 cm) iron pipe for batteries.
Make sure the pipes are clean and free of obstructions, dirt, and piping compound. A
battery requires one or two connections of appropriate size for the gas requirement.
Prior to lighting, check all joints in the gas supply line for leaks.
Use soap and water solution. Do not use an open flame.
After piping has been checked for leaks, fully purge gas pipes to remove air.
GAS PRESSURES (ALL MODELS):
The gas pressure should be set at .08” W.C. (Water Column) (0.02 kPa) for natural gas
and .08” W.C. (.02 kPa) for propane gas. If incoming pressure exceeds ½ PSI (3.45 kPa),
an additional pressure regulator must be installed.
TESTING THE GAS SUPPLY PIPING SYSTEM:
When test pressures exceed ½ PSI (3.45 kPa), the fryer and its individual shutoff valve
must be disconnected from the gas supply piping system.
When test pressures are ½ PSI (3.45 kPa) or less, the fryer must be isolated from the gas
supply piping system by closing its individual shutoff valve.
Fryers with Casters:
Separate instructions for installing casters are included with the casters:
The installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69, CAN/CGA-
6.16, and a quick-disconnect device that complies with the Standard for QuickDisconnect Devices for Use with Gas Fuel, ANSI z21.41.CSA 6.9 or QuickDisconnect Devices for Use with Gas Fuel.
GAS CONNECTION
VULCAN-HART F-32971 Rev. F (December 2011)
-8-
VK SERIES GAS FRYERS
When installing a quick disconnect you must also install a means for limiting the
movement of the fryer. This device will prevent the gas line or quick disconnect
from being strained. The restraining device should be attached to the cutout on the
back panel. See illustration for location.
The fryer must be installed with a connector (not supplied by Vulcan) complying
with the above codes.
The fryer must be installed with restraining means to guard against
transmission of strain to the connector. See illustration.
The fryer must be installed with the casters provided.
If the restraint is ever to be disconnected, first turn the gas supply off. If
disconnection of the restraint is necessary, to reconnect this restraint after the fryer
has been returned to its originally installed position.
LEVELING THE FRYER
Check the level of the fryer by placing a level on top of the fryer after gas connections
have been made.
Ensure that the fryer is level front-to-back and side-to-side in the final installed position.
If using casters, lock the wheels after unit is level.
VULCAN-HART F-32971 Rev. F (December 2011)