For additional information on Vulcan-Hart or to locate an authorized parts and
service provider in your area, visit our website at www.vulcanequipment.com
VULCAN-HART 3600 NORTH POINT BLVD.
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC BALTIMORE, MD 21222
WWW.VULCANEQUIPMENT.COM F-32971 REV. F (December 2011)
MODELS:
1VK85A ML-136891
1VK45DF ML-136895
1VK65AF ML-136897
2VK65AF ML-136906
3VK65AF ML-136915
4VK45AF ML-136921
VK SERIES GAS FRYERS
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL
GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND
ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE
EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE
OBTAINED FROM THE LOCAL GAS SUPPLIER.
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT THE MAIN
SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER
FOR SERVICE.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS
IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
IMPORTANT FOR YOUR SAFETY
IMPORTANT
FOR YOUR SAFETY
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
VULCAN-HART F-32971 Rev. F (December 2011)
-2-
VK SERIES GAS FRYERS
IMPORTANT FOR YOUR SAFETY………………………………………. 2
INTRODUCTION…………………………………………………………… 4
GENERAL…………………………………………………………… 4
ORDERING PARTS………………………………………………… 4
FRYER CAPACITIES………………………………………………. 4
UNPACKING………………………………………………………… 5
INSTALLATION……………………………………………………………. 5
Clearances………………………………………………….... 5
Location ………………..……………………………….…. 5
OPERATION………………………………………………………………… 10
OVER-TEMPERATURE SHUTDOWN……………………………. 10
BEFORE FIRST USE………………………………………………... 10
Cleaning…………………………………………………….... 10
PROGRAMMING THE SOLID STATE KNOB (A) CONTROL………… 13
PROGRAMMING THE SOLID STATE (D) CONTROL………………… 14
PROGRAMMING THE COMPUTER (C) CONTROL…………………… 15
TURNING OFF THE FRYER ……………………………………. 16
EXTENDED SHUTDOWN……………………………………….. 16
CODES AND STANDARDS……………………………………….. 6
ASSEMBLY …………..…………………………………………… 6
FLUE CONNECTION………………………………………………. 7
ELECTRICAL CONNECTION………………………………………. 7
GAS CONNECTION…………………………………………………. 8
Quick-Disconnect for Units on Casters…………………… 8
GAS PRESSURE......................................................................... 8
TEST GAS SUPPLY………………………………………………… 8
FRYERS WITH CASTERS………………………………………… 8
LEVELING THE FRYER…………………………………………… 9
FILLING TANK WITH SHORTENING…………………………… 10
BASIC FRYING INSTRUCTIONS………………………………….. 11
Fry Basket Guidelines………………………………………. 11
EXTENDED SHORTENING LIFE………………………………… 12
TURNING ON THE FRYER ………………………………………… 12
FILTERING THE OIL……………………………………………. 16
DRAINING THE TANK……………………………….…… 17
FLUE VENT INSPECTION……………………………………….. 28
Service in the US and Canada…………………………………... 28
Alarms and Error Messages…………………………………….. 28
VULCAN-HART F-32971 Rev. F (December 2011)
-3-
VK SERIES GAS FRYERS
Vulcan Fryers are produced with quality workmanship and material. Proper installation,
usage and maintenance will result in years of satisfactory performance.
Before installing the fryer, thoroughly read this manual and carefully follow all instruction.
This manual is applicable to model listed on the cover page. Procedures in this manual
will apply to all models unless specified. Pictures and illustrations can be of any model
unless the picture or illustration needs to be model specific.
Customers may order parts directly from their local authorized service center. If not
known, call Vulcan Customer Service at 800-814-2028.
To speed up your order, provide the model number, serial number, gas type, part needed,
item part number (if known) and quantity needed.
This fryer was carefully inspected before leaving the factory. Upon acceptance of the
shipment, the transportation company assumes full responsibility for safe delivery.
Immediately after unpacking the fryer, check for possible shipping damage. If the fryer is
damaged, save the packaging material and contact the carrier within 15 days of delivery.
Check that the following have been included:
Crumb Rack(s)
Basket Hanger(s)
Tank Brush
Adjustable Casters (4) two locking, two non-locking for freestanding fryers. Fryer
Batteries with the KleenScreen
from the factory.
Drain Pipe Extension for freestanding fryers only.
Twin Fry Baskets (2) per fry tank
Cleanout Rod
Fryer Batteries with the KleenScreen PLUS® Filtration System
Filter Pan
Suction Tube
Screen Assembly
Complimentary Pack of Micro-Filtration Envelopes
High temperature discard hose
Manual, Quick Start Guide(s), and Warranty – Keep in safe place for future
reference.
INTRODUCTION
GENERAL
ORDERING PARTS
UNPACKING
PLUS® Filtration System have casters installed
VULCAN-HART F-32971 Rev. F (December 2011)
-4-
VK SERIES GAS FRYERS
Do not use the door or its handle to lift the fryer.
Before installing the fryer, verify that the type of gas (natural or propane) agrees with the
specifications on the fryer data plate, which is located on the inside of the door panel.
Make sure the fryer is configured for the proper elevation.
Record your fryer model, device, and serial numbers for future reference in the space
provided below. This information can be found on the fryer data plate.
Fryer Model No: ___________________________
Device: ___________________________________
Serial No: ________________________________
Clearances
Minimum clearance from combustible construction:
6” (15 cm) from the sides of the fryer
6” (15 cm) from the back of the fryer
The fryer may be installed on combustible floors
Minimum clearance from noncombustible construction:
0” from the sides of the fryer
0” from the back of the fryer
Between the fryer and any open-top flame units:
16” (41 cm)
Allow space for servicing and operation.
Location
Install fryer in an area with sufficient air supply for gas combustion.
Do not obstruct the flow of combustion and ventilation air.
Provide adequate clearance for air openings into the combustion chamber.
Do not permit fans to blow directly onto fryer.
Keep the fryer area free and clear from combustibles.
Avoid wall-type fans, which create cross-currents within a room. Avoid
open windows next to sides or back.
INSTALLATION
VULCAN-HART F-32971 Rev. F (December 2011)
-5-
VK SERIES GAS FRYERS
CODES AND STANDARDS
The fryer must be installed in accordance with:
In the United States:
State and local codes, or in the absence of local codes, with:
National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may be
obtained from The American Gas Association Accredited Standards Committee
Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards
Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471.
NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy,
MA. 02169-7471.
National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained
from The National Fire Protection Association, Batterymarch Park, Quincy, MA.
02169-7471.
In the commonwealth of Massachusetts all gas appliances vented through a ventilation hood or exhaust system with a damper or with a power means of
exhaust shall comply with 248 CMR.
In Canada:
Local codes
CAN/CSA-B149.1 Natural Gas and Propane Installation Code (latest
edition),available from the Canadian Standards Association, 155 Queen Street,
Suite 1300, Ottawa, Ontario Canada K1P 6L1.
CSA C22.1 Canadian Electric Code (latest edition), available from the Canadian
The fryer must be restrained to prevent tipping and the splashing of hot liquid. The means
of restraint may be the manner of installation, such as connection to a battery of
appliances, installing the fryer in an alcove, or by separate means such as adequate ties.
VULCAN-HART F-32971 Rev. F (December 2011)
-6-
VK SERIES GAS FRYERS
Make the flue connection as follows:
Comply with Vapor Removal from Cooking Equipment, ANSI-NFPA
Standard #96 (latest edition), available from the National Fire Protection
Association, Batterymarch Park, Quincy, MA 02269.
Locate the fryer under a hood with adequate connection to an exhaust
duct. The hood must extend 6” (15 cm) beyond fryer on both sides.
Clearance above the fryer should be adequate for combustion byproducts
to be removed efficiently.
An 18” (46 cm) minimum clearance should be maintained between the flue
vent and the filters of the hood venting system.
Never make flue connections directly to the fryer.
Do not obstruct the flow of the gases from the appliance. Proper air
balance should be maintained in the room.
Ensure that your ventilation system does not cause a down draft at the fryer’s flue
opening. Down drafts will not allow the fryer to exhaust properly and will cause
overheating which may cause permanent damage. Damage caused by down
drafts will not be covered under equipment warranty. NEVER allow anything to
obstruct the flue of combustibles or ventilation exiting from the fryer flue. DO
NOT put anything on top of flue area.
Electrical Grounding Instructions:
This appliance is equipped with a three prong (grounding) plug for your protection against
shock hazard and should be plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from this plug. Fryer must be
electrically grounded in accordance with local codes, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA
C22.2, as applicable.
Electrical diagram located on inside of door.
FLUE CONNECTION
ELECTRICAL CONNECTION
VULCAN-HART F-32971 Rev. F (December 2011)
-7-
VK SERIES GAS FRYERS
All gas supply connections and any pipe joint compound must be
resistant to the action of propane gases.
The gas inlet is located on the lower rear of the fryer. Codes require that a gas shutoff
valve be installed in the gas line ahead of the fryer.
The gas supply line must be at least the equivalent of ½” (12.7 mm) iron pipe for single
units and 1-1/4” (31.75 mm) for batteries. If using the optional quick-disconnect flex hose,
¾” (19 mm) iron pipe for single units and 1-1/4” (31.75 cm) iron pipe for batteries.
Make sure the pipes are clean and free of obstructions, dirt, and piping compound. A
battery requires one or two connections of appropriate size for the gas requirement.
Prior to lighting, check all joints in the gas supply line for leaks.
Use soap and water solution. Do not use an open flame.
After piping has been checked for leaks, fully purge gas pipes to remove air.
GAS PRESSURES (ALL MODELS):
The gas pressure should be set at .08” W.C. (Water Column) (0.02 kPa) for natural gas
and .08” W.C. (.02 kPa) for propane gas. If incoming pressure exceeds ½ PSI (3.45 kPa),
an additional pressure regulator must be installed.
TESTING THE GAS SUPPLY PIPING SYSTEM:
When test pressures exceed ½ PSI (3.45 kPa), the fryer and its individual shutoff valve
must be disconnected from the gas supply piping system.
When test pressures are ½ PSI (3.45 kPa) or less, the fryer must be isolated from the gas
supply piping system by closing its individual shutoff valve.
Fryers with Casters:
Separate instructions for installing casters are included with the casters:
The installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69, CAN/CGA-
6.16, and a quick-disconnect device that complies with the Standard for QuickDisconnect Devices for Use with Gas Fuel, ANSI z21.41.CSA 6.9 or QuickDisconnect Devices for Use with Gas Fuel.
GAS CONNECTION
VULCAN-HART F-32971 Rev. F (December 2011)
-8-
VK SERIES GAS FRYERS
When installing a quick disconnect you must also install a means for limiting the
movement of the fryer. This device will prevent the gas line or quick disconnect
from being strained. The restraining device should be attached to the cutout on the
back panel. See illustration for location.
The fryer must be installed with a connector (not supplied by Vulcan) complying
with the above codes.
The fryer must be installed with restraining means to guard against
transmission of strain to the connector. See illustration.
The fryer must be installed with the casters provided.
If the restraint is ever to be disconnected, first turn the gas supply off. If
disconnection of the restraint is necessary, to reconnect this restraint after the fryer
has been returned to its originally installed position.
LEVELING THE FRYER
Check the level of the fryer by placing a level on top of the fryer after gas connections
have been made.
Ensure that the fryer is level front-to-back and side-to-side in the final installed position.
If using casters, lock the wheels after unit is level.
VULCAN-HART F-32971 Rev. F (December 2011)
-9-
VK SERIES GAS FRYERS
Hot oil and parts can cause burns. Use care when operating,
cleaning and servicing the fryer.
Spilling hot frying compound can cause severe burns. Do not move
fryer without draining all frying compound from the tank.
Fryer is not to be used during a power outage.
If the shortening becomes overheated, a high-temperature shutoff device will turn the gas
valve off.
If the fryer shuts down due to overheating, DO NOT power up the fryer until the shortening
temperature is below 300°F (149°C).
If an overheating situation persists, contact your local Vulcan-Hart authorized service
office.
Cleaning
New units are wiped down at the factory to remove any visible signs of dirt, oil, grease,
etc. remaining from the manufacturing process.
Before any food preparation, thoroughly wash the protective oil from all surface parts and
the tank interior with hot soapy water to remove any film residue and dust or debris.
Do not use chlorine or sulfate/sulfide cleaners.
Wash any accessories shipped with unit.
Rinse fryer and accessories thoroughly and drain the fryer.
Wipe tank completely dry with a soft, clean cloth.
Close the drain valve.
Fill the fryer tank with liquid shortening.
Shortening level should be between the min and max lines in the fryer tank.
Shortening will expand when heated. Do not fill the fryer tank past the
MAX line.
Add fresh shortening as needed to maintain oil level.
OPERATION
OVER-TEMPERATURE SHUTDOWN
BEFORE FIRST USE
VULCAN-HART F-32971 Rev. F (December 2011)
-10-
VK SERIES GAS FRYERS
BASIC FRYING INSTRUCTION
Set the desired temperature and allow shortening to heat up to that temperature.
Fry items that are the same size to ensure equal doneness.
Drain or wipe dry raw or wet foods to minimize splatter when lowering into hot
shortening.
Add fresh shortening as needed.
Fry Basket Guidelines
Do not overfill baskets. (See table for recommended basket capacities below)
Carefully lower basket into oil.
When frying doughnuts and fritters, turn product only once during frying.
When cooking French fries or onion rings, shake the basket several times.
Batter covered foods should be dropped carefully, one by one, into shortening or
basket. If you use the basket, first dip the basket into the shortening to
reduce batter-build up on basket surfaces.
When frying is completed, remove basket or product. Hang basket on rear
hanger.
Fry Basket Capacity:
1VK45: Recommended pounds per basket are 2.5 lbs. (1.1 kg).
1VK65: Recommended pounds per basket are 3.0 lbs. (1.4 kg).
1VK85: Recommended pounds per basket are 3.5 lbs. (1.6 kg).
EXTENDING SHORTENING LIFE
Shortening life can be extended by the following guidelines:
Do not salt foods over the fryer.
Use good-quality shortening.
Filter shortening daily (at a minimum).
Replace shortening if it becomes poorly flavored.
Keep equipment and surrounding clean. Use tank covers when not in use.
(accessory).
Set thermostat correctly.
Remove excess moisture and particles from food products before placing on fryer.
VULCAN-HART F-32971 Rev. F (December 2011)
-11-
VK SERIES GAS FRYERS
TURNING ON THE FRYER
VKA solid state knob control:
Open the door to the fryer. Turn the power switch to the on position.
Indicator Lights
(On/Start/Heating)
Temperature Knob Control Melt Switch
Power Switch Filter Switch
(For those models with KleenScreen
PLUS® Filter Systems)
Start Button
Open the door to the fryer. Select Liquid or Solid Shortening pressing the
switch to the desired selection.
Set temperature by turning the knob to the desired temperature.
Press the power switch to the ON position. The burners will not light until the
next step is completed.
Press the START switch once for the burners to light. The START switch is a
momentary switch and will reset after being pressed. The indicator light will
change from Red to Green. Heating light will glow Yellow.
The power burner will cycle on and off throughout the melt cycle. When the fry
tank oil reaches 135° F the burners will stop cycling and remain on until the set
temperature is reached. Once set temperature is reached the burners will cycle
on and off to maintaining the set temperature.
VKD solid state digital and VKC programmable controls:
For solid state digital and programmable computer controls the power burner will light
automatically. The power burner will cycle on and off throughout the melt cycle and continue
afterwards maintaining the set temperature.
VULCAN-HART F-32971 Rev. F (December 2011)
-12-
VK SERIES GAS FRYERS
VULCAN-HART F-32971 Rev. F (December 2011)
-13-
VK SERIES GAS FRYERS
Programming the Solid State Control
Programming the Computer Control
VULCAN-HART F-32971 Rev. F (December 2011)
-14-
VK SERIES GAS FRYERS
Open the door to the fryer. Press the power switch to the OFF position.
1. Thoroughly drain the fryer. Refer to DRAINING THE FRYER.
2. Clean the fryer according to CLEANING.
3. Turn off the main gas shutoff valve.
TURNING OFF THE FRYER
EXTENDED SHUTDOWN
VULCAN-HART F-32971 Rev. F (December 2011)
-15-
VK SERIES GAS FRYERS
1. Press the power switch to the off position.
Hot oil and hot parts can cause burns. Use care when operating,
cleaning, and servicing the fryer.
Filter shortening at least once a day.
1. Do NOT turn off the power to the fryer. Leave power on.
2. Insert the drain extension into the drain valve. Tighten only hand tight.
3. Direct the drain extension into the mobile filtering device that you want to use.
4. A cold fryer will not drain easily. Always filter shortening between 250°F
and 350°F. The shortening in the cold zone area will remain hard if the heat is only on for
a few minutes. If necessary, use the clean-out rod to carefully move the hard shortening
to an area above the cold zone where it will melt.
5. Slowly open the drain valve to allow oil to flow from the fry tank to the filter pan. Then open
the drain valve all the way. Please note the gas power burner will automatically turn off at
this point. DRAINING will appear on the digital display for solid state digital (D) and
DRAINING OIL will display on computer models (C).
6. When fry tank is empty use the tank brush to remove any additional debris.
7. Close the drain valve. The display will change to; FILL TANK for solid state digital models
(D) and FILL TANK for computer models (C).
8. Fill tank with new shortening. Fill to a minimum of the MIN level but no higher than halfway
between MIN and MAX. Oil will expand as it is heated.
9. On solid state digital models (D) and computer models (C) models, the display will ask if
the tank is full; TANK FULL, HIT TEMP. If the tank is full, press the Temp Button on the
display. Once pressed, the gas power burner will ignite and begin heating the oil to desired
temperature.
10. Press the START button for solid state knob control (A) and gas power burner with ignite
and begin heating the oil.
TURNING OFF THE FRYER
FILTERING THE OIL
VULCAN-HART F-32971 Rev. F (December 2011)
-16-
VK SERIES GAS FRYERS
Free Standing Models:
1. Turn off fryer.
2. Insert the drain extension into the drain valve. Tighten only hand tight.
3. Direct the drain spout into the container that you want to drain the shortening into.
4. Open the drain valve. The oil will drain into the container. When the container is
full or the fryer tank is empty, close the drain valve. Repeat this step until the fryer
is empty. Remove the drain extension and place it back into the provided holder.
5. It is recommended to now boil out your fry tank. Follow the Boil Out procedure.
Then perform the weekly clean-out as described under CLEANING.
6. Once tank is completely empty, boiled out and cleaned, add new shortening. Turn
on the power switch to begin heating the oil to desired temperature.
Weekly or when oil is replaced:
Free Standing Models:
1. Drain the tank as described under FILTERING THE OIL.
2. Close the drain valve and fill tank with water. Use a boil out solid degreaser low which
can be ordered from your local dealer
Do not use chlorine or sulfate/sulfide cleaners.
3. Solution level must be between the MIN and MAX levels on the fryer tank.
4. Turn the power switch to the on position. With solid state knob controls(A), set the
temperature knob to 200°F. Press the start button. Water boils at 212°F. For solid
state digital models (D) and computer models (C) models, the temperature will
automatically set for 195-200°F. Do not bring water temperature to an overly active
boil.
5. Use the tank brush; clean the sides, bottom and heat exchanger tubes.
6. Place the drain extension in the drain valve and hand tighten only. Drain the cleaning
solution from the tank into a container.
7. Close the drain valve and refill the tank with water. Add 1 cup (1/4 L) of vinegar to
neutralize alkaline left by the cleaner. Solution level must be between the MIN and
DRAINING THE TANK
BOIL OUT PROCEDURE
. Follow the instructions on the side of the package.
VULCAN-HART F-32971 Rev. F (December 2011)
-17-
VK SERIES GAS FRYERS
MAX level on the fryer tank. Press the start button for (A) and Temp Button for (D)
and C) models, to allow the solution to heat up. Allow solution to stand for a few
minutes.
8. Drain the tank according to DRAINING THE TANK. Rinse thoroughly with clear, hot
water. All traces of cleaner must be removed. Dry the tank thoroughly.
9. Close the drain valve and add shortening. Follow the FILLING TANK WITH
SHORTENING procedure in this manual. The fryer is now ready for use. Press the
start button for (A) and Temp Button for (D) and C) models, to allow the solution to
heat up.
Hot oil and hot parts can cause burns. Use care when operating,
cleaning, and servicing the fryer.
Daily
Clean your fryer regularly with the tank brush along with a damp cloth, and polish with a
soft dry cloth. If regular cleaning is neglected, grease will be burned on and discolorations
may form.
Fingerprints are sometimes a problem on highly polished surfaces of stainless steel. They
can be minimized by applying a cleaner that will leave a thin oily or waxy film.
Clean all exterior surfaces of your fryer at least once daily.
Use a damp cloth with warm water and a mild soap or detergent.
Do not use chlorine or sulfate/sulfide cleaners.
Rinse thoroughly, and then dry with a soft dry cloth.
Keep the fryer exterior clean and free of accumulated grease to prevent
stubborn stains from forming. If regular cleaning is neglected, grease will be
burned on and discolorations may form.
Remove discolorations by washing with any detergent or soap and water.
Use a self-soaping, non-metallic scouring pad for particularly stubborn
discolorations.
Always rub with the grain of the stainless steel.
Do not use a metallic scoring pad or harsh cleaners.
CLEANING
VULCAN-HART F-32971 Rev. F (December 2011)
-18-
VK SERIES GAS FRYERS
KleenScreen Plus® Filtration System
Installation & Operational Manual for “VKAF”, VKDF” and “VKCF”
Models
General
The KleenScreen PLUS® filtration system filters the oil as it is pumped back into its’ respective
tank(s). Only one tank can be drained and filtered at a time. Under no circumstances should both
tanks be drained at the same time.
Assembly
After unpacking, wash the filter pan, crumb basket and filter screen assembly. Make sure
you remove the insert located inside the filter screen. Use dishwashing detergent and warm
water, (parts are dishwasher safe). Rinse the filter pan, crumb basket and filter screen
components completely and wipe all parts dry with a clean cloth.
Pull out the filter drawer all the way leaving the filter pan opening exposed.
Place the filter tank into the filter drawer making sure that the pins on the bottom of the filter
pan line up with the holes in the filter drawer. Position the filter screen assembly into the
suction tube clip in the filter pan positioning the filter screen assembly flat on the bottom of
the filter pan. Place the primary crumb basket onto the left handle of the filter pan.
Carefully line up the suction tube nozzle so that it mates with the oil receptacle block
mounted on the frame of the fryer battery. Close the drawer. See Figures 1, 2 3 and 4
Suction Tube
Filter Screen
Filter Insert
Knurled Bottom
Fitting
Fig. 1
VULCAN-HART F-32971 Rev. F (December 2011)
-19-
VK SERIES GAS FRYERS
Fully assembled filter screen assembly:
Fig. 2
Secure Tube with
Suction Tube Clip
Filter Screen Lays
Flat On Bottom of
Filter Pan
Fig. 3
Micro-Filtration Fabric Envelope Assembly:
Fabric Envelope Insert
(Different from Screen Assembly)
Fabric Envelope
Same Knurled Knob
Same Suction Tube
Closing Clip
Fig. 4
VULCAN-HART F-32971 Rev. F (December 2011)
-20-
VK SERIES GAS FRYERS
INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS® FILTER ENVELOPE
FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RATE WE RECOMMEND YOU CHANGE YOUR FILTER
ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).
Step 1
Discard all oil from the filter vessel, (see pages 23 or 24). When the
filter pan is empty, use a spatula and scrape off all debris left on the
filter envelope and in the filter pan.
Step 2
Unscrew “S” Tube from filter by turning the Bottom Knurled fitting
counter- clockwise.
Step 3
Remove SST Closure Clip by lifting off one side.
Step 4
Remove SST Filter Screen Insert and wash insert with hot water and
dry thoroughly. The Filter Screen Insert is dishwasher safe. Place the
insert into a new KleenScreen PLUS® Filter envelope.
DO NOT WASH FABRIC ENVELOPE
Step 5
Place Filter Screen Insert into the fabric envelope making sure that the
holes line up. Fold over the other end of the envelope and place SST
Closure Clip on – hinge over and firmly press clip all the way down to
secure and seal filter assembly. Making sure that the folded end is face
down; screw “S” Tube Assembly onto the Filter Assembly. Tighten the
Bottom Knurled fitting. When tightened, the “S” Tube assembly should
be perpendicular to the long side of the filter assembly.
Step 6
Reposition the filter tube into the provided clip. Align filter tube so that
the end of the “S” Tube engages the Oil Receptacle fitting each time the
drawer is opened and closed.
VULCAN-HART F-32971 Rev. F (December 2011)
-21-
VK SERIES GAS FRYERS
Operation
Hot oil and parts can cause burns. Use care when operating,
cleaning and servicing the fryer.
Spilling hot frying compound can cause severe burns. Do not move
fryer without draining all frying compound from the tank.
Never run water or boil out solution through filter and motor / pump. Doing so
will void your fryer warranty.
FILTERING PROCEDURE
Oil Temperature should be 300-350° F. Use the provided crumb scoop to remove and suspend
crumbs on the bottom of the tank before proceeding to Step 1.
1. Do not turn off the Fryer. The power must be on throughout the entire filtering process.
Do NOT heat the fryer during the filtering procedure. Permanent damage to your fry
tank may occur and warranty may be voided.
2. Vulcan recommends adding an oil treatment media to the oil prior to filtering.
3. Make sure that the filter drawer is closed completely and that the suction tube and
receptacle block are in the correct position. Fig. 5
Fig. 5
VULCAN-HART F-32971 Rev. F (December 2011)
-22-
VK SERIES GAS FRYERS
VULCAN-HART F-32971 Rev. F (December 2011)
-23-
VK SERIES GAS FRYERS
Filtering Instructions for Solid State Controls
VULCAN-HART F-32971 Rev. F (December 2011)
-24-
VK SERIES GAS FRYERS
Filtering Instructions for KleenScreen PLUS® Fryers with Computer Controls
VULCAN-HART F-32971 Rev. F (December 2011)
-25-
VK SERIES GAS FRYERS
FILTERING TIP:
Open the filtering drawer approximately 1” to allow any oil in the return line to run back into the filter
pan. This will take about 30 seconds to complete. Then open the drawer completely to clean filter
components.
REMOVING EXCESS DEBRIS FROM THE SCREEN FILTER:
1. Pull the filter drawer out and remove the crumb basket and empty any debris into the trash.
2. Remove the filter screen assembly. Scrape debris from the filter screen. Then remove the
insert by unlatching the latch. Clean all parts thoroughly as mentioned in the Assembly
section on page 19.
3. Scrape debris from the bottom of the filter pan and discard in the trash. Clean all parts
thoroughly as mentioned in the Assembly section on page 19. Clean all parts thoroughly as
mentioned in the Assembly section on page 19.
4. Reassemble all filter components after being dried thoroughly as in the Assembly section on
page 19.
FLUSH AND DISCARD:
1. Follow filtering instructions 1-3, however do not put oil treatment media into the fryer. Drain
the fryer oil into the filter pan.
2. Attach the quick disconnect hose to the discard male quick disconnect fitting, (hose not
supplied with fryer – Accessory Option).
3. Place other end of the discard hose into a container that is large enough to retain the
discarded shortening.
4. With the power switch still ON; press the discard/flush switch on. Press and hold the filter
button for at least 3 seconds and the Motor/Pump will begin to operate. NOTE: Oil will come
out immediately out of the nozzle end of the hose.
5. Once the oil has been discarded completely and the filter pan is empty, press the filter button
to turn off the Motor/ Pump. Then press the discard/flush switch off.
6. Disconnect the discard hose. The hose connection will be hot due to the temperature of the
oil that was discarded. Be careful to let the hose drain before putting away. Close the drain
valve and fill the fry tank with new oil.
7.
VULCAN-HART F-32971 Rev. F (December 2011)
-26-
VK SERIES GAS FRYERS
BOIL OUT PROCEDURE:
Use the Boil Out By-Pass™ drain extension allowing the boil
out solution to exit the fry tank without using the filtering
system. Do NOT allow water to run through the motor / pump.
Drain the boil out solution into a bucket or place a high
temperature rated water hose on the end of the drain extension
allowing the other end to flow into a floor drain. In Fig. 6 the
arrow is pointing to the drain extension. It is threaded into the
top coupling of the oil drain tube. Drain extension needs to be
only hand tightened.
Standard Hose End Drain Tube End
THERMAL OVERLOAD PROTECTION BUTTON:
The motor/pump supplied with the
filtering system has a thermal
overload protection circuit that
senses when excess heat occurs.
This can occur due to filtering for
long periods of time or under heavy
load prior to discarding debris
buildup. If the thermal overload
protection is tripped, wait 5 minutes
and then reset the motor by pushing
in the red button. The arrow in
Figure 7 shows the location of the
reset button; located on the front off
the motor / pump facing towards you.
Hot oil and hot
parts can cause burns.
Fig. 6
Fig. 7
VULCAN-HART F-32971 Rev. F (December 2011)
-27-
VK SERIES GAS FRYERS
Hot oil and hot parts can cause burns. Use care when operating,
cleaning, and servicing the fryer.
Spilling hot fryer compound can cause severe burns. Do not
move fryer without draining all frying compound from the tank.
When the fryer is cool, inspect annually. Check the flue and clear any obstructions.
Service in the US and Canada
Contact you local Vulcan-Hart Service office or address on the front of this manual.
NO OR LOW GAS SUPPLY – If no action is taken after 90 seconds, an alarm sounds
continuously, the heat demand is disabled and any running cooking cycles are cancelled.
The digital display the following message:
“D” Solid State – IGNITION LOCKOUT
“C” Computer – IGNITION LOCKOUT CHECK GAS SUPPLY
The fryer must be turned off, then back on to re-initialize the control and to have normal
functions resumed.
OPEN PROBE – If an open probe is detected, the heat demand is disabled and any running
cooking cycles are cancelled. All operator buttons are disabled. The digital control displays
the following message:
“D” Solid State – OPEN PROBE
“C” Computer – PROBE OPEN
MAINTENANCE
FLUE VENT INSPECTION
ALARMS AND ERROR MESSAGES
VULCAN-HART F-32971 Rev. F (December 2011)
-28-
VK SERIES GAS FRYERS
SHORTED PROBE – If a shorted probe is detected, the heat demand is disabled and any
running cooking cycles are cancelled. All operator buttons are disabled. The digital control
displays the following message:
“D” Solid State – SHORTED PROBE
“C” Computer – PROBE SHORT
Hi TEMPERATURE – If the temperature is greater than or equal to 415°F (212°C), the heat
demand is disabled and any running cooking cycles are cancelled. All operator buttons are
disabled. The control displays the following message:
“D” Solid State – HIGH TEMP
“C” Computer – HIGH TMP HIGH TMP
Troubleshooting Chart:
Problem: Probable Cause:
No Heat: Power switch not turned on.
Gas supply not turned on.
Wire connections loose (call service)
Wires connections need cleaning
High Limit (call service)
Insufficient or too much heat: Temperature not set to desired temperature.
High limit tripped (call service)
Temperature probe (call service)
Tank will not drain: Shortening too cold.
Drain pipe clogged with debris.
Motor / pump will not pump oil: Suction tube not seated correctly in receptacle block.
Filter screen is clogged and needs cleaning.
Shortening is too thick / cold. Heat oil up to min. 300º F.
Discard valve lever not fully engaged either for filtering or
discarding.
VULCAN-HART F-32971 Rev. F (December 2011)