SPECIFICATIONS:
Direct steam convection steamer, Vulcan-Hart Model No.
(VHX24D)(VHX24D5). Convection steamer mounted on 28"
high base cabinet with stainless steel frame, front full height
doors, slip-off stainless steel side and aluminized rear panel
with 6" adjustable legs with flanged feet for anchoring. Two
stainless steel cooking compartments with coved interior corners.
1
/4" drain in each compartment. Heavy duty stainless steel
1
"slammable" doors can be opened and closed at anytime during
the cooking cycle. Steam shuts off when door(s) are opened.
15 psi pressure relief valve and 15 psi kettle connection. Direct
steam supply at 10 - 50 psi with flow of 138 lbs. steam/hr.
Compartment controls include 60 minute dial timer with buzzer,
green "ready" and red "cooking" indicator lights. Stainless steel
cover flue. Service connections include
for boiler feed and 1/8" cold water condenser, 120 volt control
circuit and 1
1
/4" drain connection.
1
/2 " cold water connection
Exterior dimensions: 24"w x 35.4"d x (60.37)(73")"h.
CSA design certified. Classified by U L to NSF Std. #4.
Item # __________________________
C.S.I. Section 11420
VHXD SERIES
DIRECT STEAM CONVECTION STEAMERS ON
CABINET BASE
■■ VHX24D 6 pan capacity
■■ VHX24D5 10 pan capacity
STANDARD FEATURES
■ Convection steamer mounted on 28" high base cabinet with
stainless steel frame, front full height doors, slip-off stainless
steel side and aluminized rear panel with 6" adjustable legs
with flanged feet for anchoring.
■ Two stainless steel cooking compartments with coved interior
corners. Each compartment accepts:
- 1" deep pans (6 - VHX24D)(10 - VHX24D5)
1
/2" deep pans (3 - VHX24D)(5 - VHX24D5)
-2
- 4" deep pans (2 - VHX24D)(3 - VHX24D5)
1
■ 1
/4" compartment drain.
■ Heavy duty stainless steel "slammable" doors can be opened
and closed at anytime during the cooking cycle. Steam shuts
off when door(s) are opened.
■ 15 psi pressure relief valve and 15 psi kettle connection.
■ Direct steam supply at 10 - 50 psi with flow of 138 lbs. steam/hr.
■ Compartment controls include 60 minute dial timer with
buzzer, green "ready" and red "cooking" indicator lights.
■ Stainless steel flue cover.
■ Service connections include,
boiler feed and 1/8" cold water condenser, 120 volt control
circuit and 1
1
/4" drain connection. (See detail on back page.)
■ One year limited parts and labor warranty.
OPTIONS
■■ Correction facility package:
a. Cabinet door with hasp (lock by others).
b. Control cover (lock by others).
c. Tamper resistant fasteners.
d. Flue riser cover.
■■ Mount and interconnect boiler base with kettle at factory.
Includes steam supply piping. Shipped on one skid.
■■ Second year extended limited parts and labor warranty.
ACCESSORIES
■■ Stainless steel back panel.
■■ Interconnecting steam supply plumbing between VHX and
freestanding kettle. Kettle must be within 2 feet to left or right.
■■ Removable sliding shelf. Qty.___.
1
/2" cold water connection for
Vulcan-Hart Co.
ISO9001
A2780
MODEL: VHXD SERIES
Direct Steam Convection Steamers on Cabinet Base
F-32567 (10-03)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
VHXD SERIES
DIRECT STEAM CONVECTION STEAMERS
ON CABINET BASE
SERVICE CONNECTIONS
STEAM SUPPLY:
ELECTRICAL CONNECTION FOR CONTROLS: 120/60/1, 300
watt maximum, power supply with grounding wire
required. (For other than 120 volt supply consult factory for
location of this connection.)
DRAIN: Condenser box, compartment and boiler, 11/4" NPT.
Provide an open air gap type drain within 12" of condenser box
and for best results at a distance so that steam vapors will not
enter the steamer from underneath the control area. Do not
connect solidly to any drain connection.
COLD WATER CONNECTION: 1/8" NPT for condensate box.
Inlet water pressure between 20 and 60 psi.
STEAM TAKE-OFF CONNECTION:
3
/4" NPT for 10 - 50 psi direct steam.
3
/4" NPT.
NOTE:
• Dimensions which locate the above connections have a tolerance of +
or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other specific code requirements is the responsibility of the owner and installer.
It is the responsibility of the owner and installer to comply with local
codes.
• Plastic drains are not recommended due to inherent limited temperatures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge water
temperature to be that of the condensate temperature of 140°F or less.
• This appliance is manufactured for commercial installation only and is
not intended for home use.
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
F-32567 (10-03)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
Printed On Recycled Paper