Vulcan-Hart ScaleBlocker SPS600V, ScaleBlocker SPS620V Specifications

Item # __________________________
C.S.I. Section 11420
ScaleBlocker
WATER FILTER SYSTEM
SPS600V
SPS620V
STANDARD FEATURES
Single cartridge design.
Patented technology reduces limescale with-out chemicals
or additives.
Reduces the need for deliming.
Mounting bracket with clear filter housing and red cap.
Shut off valve and pressure gauge.
Incoming water parameter:
pH 6-9 Alkalinity ppm 80 - 100 Chlorine ppm 0 - 4 Hardness ppm 0 - 300
3
4 NPTF inlet and outlet.
Shut off valve with cold water for unfiltered connection.
Water pressure gauge.
Water flow meter with reminder setting.
1
/4" compression connection
Vulcan-Hart Co.
ISO9001
A2780
MODELS: SCALEBLOCKER
Water filter system, Vulcan-Hart Model No. SPS___V. Single cartridge design. Patented technology reduces limescale with­out chemicals or additives. Reduces the need for deliming. Mounting bracket with clear filter housing and red cap. Shutoff valve and gauge. Incoming water parameters are pH 6 - 9, Alkalinity ppm 80 - 100, Chlorine ppm 0 - 4, Hardness ppm 0 - 300.
Exterior dimensions:
SPS600V: 14"w x 10"d x 18 SPS620V: 14"w x 10"d x 28"h.
NSF tested and certified.
3
4 NPTF inlet and outlet.
1
/2"h.
Water Filter System
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
F-32428 (6-04)
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
SPS600V
ScaleBlocker™
WATER FILTER SYSTEM
NOTES:
1. Dimensions which locate the below connections have a
tolerance of + or - 3" (+ or - 77mm).
SPS600V
Service Flow 0-2 GPM Service Life 7,500 Gal Inlet / Outlet 3/4" NPT F Inlet Min / Max Pressure 40-125 PSIG Min / Max Temperature 45-100F (7-37C) Weight, Operating 21 Lbs. (9.5 kg)
SPS620V
Service Flow 0-4 GPM Service Life 12,000 Gal Inlet / Outlet 3/4" NPT F Inlet Min / Max Pressure 40-125 PSIG Min / Max Temperature 45-100F (7-37C) Weight, Operating 32 Lbs. (15.5 kg)
2. Installation of backflow preventers, vacuum breakers, other
code requirements and local code compliance is the respon­sibility of the owner and installer.
3. Filter clearance needed for access:
Front 13" Bottom 4"
4. Plastic drains are not recommended due to inherent limited
temperatures of the plastic. Boiler purge temperatures may exceed 180°F. The installer may be required to provide means to reduce boiler purge water temperatures to be that of condensate temperature of 140°F or below.
5. This appliance is manufactured for commercial installation
only and not intended for home use.
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and specifications without notice.
F-32428 (6-04)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
SPS620V
WATER QUALITY STATEMENT:
Water from ScaleBlocker™ System should only be connected to the boiler / generator feed and not the condenser connection of the steamer. Systems are not to be used where water is microbiologically unsafe or with water of unknown quality without adequate disinfections before and after use. Connecting to a municipal water supply complies with this requirement.
Printed On Recycled Paper