Vulcan-Hart LG300, LG400, ML-136643, LG500, ML-136258, ML-136222 Service Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
SERVICE MANUAL
LG Series Fryer
LG300ML-136528
LG400ML-136622
LG500ML-136643
- NOTICE -
This Manual is prepared for the use of trained Vulcan Service
Technicians and should not be used by those not properly
qualified.
This manual is not intended to be all encompassing. If you have
not attended a Vulcan Service School for this product, you should
read, in its entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not have the necessary tools, instruments and skills should be
performed by a trained Vulcan Service Technician.
The reproduction, transfer, sale or other use of this Manual,
without the express written consent of Vulcan, is prohibited.
This manual has been provided to you by ITW Food Equipment
Group LLC ("ITW FEG") without charge and remains the property
of ITW FEG, and by accepting this manual you agree that you will
return it to ITW FEG promptly upon its request for such return at
any time in the future.
A product of Vulcan-Hart3600 North Point Blvd Baltimore, MD 21222
F45691 (1117)
LG Series Fryer
TABLE OF CONTENTS
GENERAL .................................................................................................. 3
This manual is applicable only to models listed on the
cover page. Procedures in this manual will apply to all
models unless specified. Pictures and illustrations can
be of any model unless they need to be model specific.
INSTALLATION, OPERATION AND
CLEANING
For detailed installation, operation and cleaning
instructions, refer to the Installation & Operation
Manual sent with each unit. The manual is also
available online at www.vulcanequipment.com.
TOOLS
Standard
•Standard set of hand tools.
•VOM with minimum of NFPA-70E CATIII 600V,
UL/CSA/TUV listed. Sensitivity of at least 20,000
ohms per volt. Meter leads must also be rated at
CAT III 600V.
•Temperature tester (thermocouple type).
•ESD (Electrostatic discharge) Protection Kit.
Special
•Manometer.
SPECIFICATIONS
Gas Data
ModelNo. TubesBTU/HR
LG300390,000
LG4004120,000
LG5005150,000
Page 3 of 23F45691 (1117)
LG Series Fryer - REMOVAL AND REPLACEMENT OF PARTS
REMOVAL AND REPLACEMENT OF PARTS
COVER PANELS
Door
Be prepared to catch door when bottom hinge is
removed.
1.Remove door hinge screws while supporting
door.
Fig. 3
4.Reverse procedure to install.
Back Panel
1.Remove rear panel mounting screws.
Fig. 1
2.Reverse procedure to install.
Heat Shield
1.Remove DOOR.
2.Remove heat shield mounting screws.
Fig. 2
3.Angle heat shield to remove.
Fig. 4
2.Reverse procedure to install.
Flue Wrap
1.Remove screws securing flue wrap.
F45691 (1117)Page 4 of 23
LG Series Fryer - REMOVAL AND REPLACEMENT OF PARTS
3.Push up on burner while pulling bottom of burner
Fig. 5
forward to clear burner nozzle.
Fig. 7
2.Reverse procedure to install.
Flue Box
1.Remove FLUE WRAP.
2.Remove screws securing flue box.
Fig. 6
3.Reverse procedure to install.
BURNERS
4.Reverse procedure to install.
THERMOSTAT
Oil may be hot when draining fryer tank.
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
1.DRAIN FRYER TANK .
NOTE: Steps to remove Heat Shield can be skipped
if back of fryer is accessible. Remove BACK PANEL
to access thermostat probe packing nut.
2.Remove HEAT SHIELD.
3.Remove LEFT BURNER.
4.Pull thermostat knob (1, Fig. 8) off thermostat
shaft.
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
1.Remove HEAT SHEILD.
2.Loosen mounting bolts at top of burner being
removed.
Page 5 of 23F45691 (1117)
LG Series Fryer - REMOVAL AND REPLACEMENT OF PARTS
Fig. 10
8.Remove thermostat bulb from clamp.
Fig. 8
5.Remove thermostat mounting screws (Fig. 8)
and bracket.
6.Note and disconnect thermostat wiring.
Fig. 11
9.Remove thermostat assembly.
10. Reverse procedure to install.
Take care not to kink thermostat capillary when
installing. Wrap threads of packing nut with teflon tape
to prevent leakage.
HIGH LIMIT THERMOSTAT
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.