OPERATION MANUAL
VPX SERIES STEAMERS
MODELS
VPX3 ML- 126586
VPX5 ML- 126588
INSTALLATION &
www.energystar.gov
For additional information on Vulcan-Hart or to locate an authorized parts
and service provider in your area, visit our website at www.vulcanhart.com
VULCAN-HART
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC
WWW.VULCANHART.COM
Model VPX3
P.O. BOX 696, LOUISVILLE, KY 40201-0696
TEL. (502) 778-2791
FORM 31136 Rev. A (08-04)
TABLE OF CONTENTS
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation Codes and Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Leveling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Service Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Water Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Vent Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Before First Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Testing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Operating the Steamer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Steam Cooking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Acceptable Pan Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Cooking Tips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Service and Parts Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
© VULCAN-HART, 2004
– 2 –
INSTALLATION, OPERATION AND CARE OF
MODEL VPX SERIES STEAMERS
PLEASE KEEP THIS MANUAL FOR FUTURE USE
GENERAL
The Vulcan-Hart steamer cooks vegetables, frankfurters, eggs, chicken, sausage, fish, corned
beef, and many other meats and food items. These steamers are produced with quality materials
and workmanship.
The VPX3 Steamer is rated at 9.0 kW and the VPX5 Steamer is rated at 15.0 kW.
Proper installation, usage and maintenance of your steamer will result in many years of satisfactory
performance.
Thoroughly read this entire manual and carefully follow all of the instructions provided.
INSTALLATION
Before installing, verify that the electrical service agrees with the specifications on the machine data
plate located on the left side panel. If the supply and equipment requirements do not agree, do not
proceed with the installation. Contact your dealer or Vulcan-Hart immediately.
UNPACKING
This steamer was inspected before leaving the factory. The transportation company assumes full
responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking,
check for possible shipping damage. If the steamer is found to be damaged, save the packaging
material and contact the carrier within 15 days of delivery. Carefully unpack the steamer and place
in a work-accessible area as near to its final installed position as possible.
LOCATION
The installation location must allow adequate clearances for servicing and proper operation.
Minimum clearances for proper air circulation is 2" (5.1 cm) on the sides and 6" (15.2 cm) on the
back.
ASSEMBLY
This steamer comes with four 4
steamer on its left side, being careful to avoid scratching the finish. Place one flat washer on the bolt
side of each leg. Thread the four legs into the provided mounting holes. Do not mount steamer
directly to a counter top unless the support legs are in place.
1
/2" (11.4 cm) support legs and four large flat washers. Place the
– 3 –
INSTALLATION CODES AND STANDARDS
The steamer must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Local codes.
2. Canadian Electric Code, CSA C22.2 (latest edition). Copies may be obtained from The
Canadian Standard Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario,
Canada L4W 5N6.
LEVELING
The steamer must be level for proper operation. Place a carpenter's level on top of the steamer.
Level the steamer front to back and side to side by turning the adjustable feet.
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
When making electrical connections, use copper wire suitable for at least 200°F (90°C). The
steamer must be grounded. The wiring diagram is located on the inside of the right panel.
Steamers wired for 1 phase can be changed to 3 phase or vice versa by relocating the jumper wires
on the terminal block as shown on the wiring diagram.
ELECTRICAL DATA
Model Volts KW Amp @ 1 PH Amp @ 3 PH
208
VPX3 240
480
208
VPX5 240
480
6 28.9 NA
9 43.3 25
625 NA
9 37.5 21.7
6 12.5 NA
9 18.8 10.9
10 48.1 NA
15 72.2 41.7
10 41.7 NA
15 62.5 36.1
10 20.9 NA
15 31.3 18.1
– 4 –