Vulcan Hart MGH14A Operators Manual

SERVICE MANUAL & CATALOG OF
GAS HOTPLATE
MODEL
MGH14A ML-103826
REPLACEMENT PARTS
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791
FORM 30972 (5-97)
MGH14A GAS HOTPLATE REPLACEMENT PARTS
REPLACEMENT PARTS MGH14A GAS HOTPLATE
MGH14A MEDIUM DUTY
GAS COUNTER HOTPLATE
SERVICE
WARNING: THE HOTPLATE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING,
CLEANING OR SERVICING THE HOTPLATE.
REMOVING BURNERS
Lift the top grates, then lift the burners carefully and maneuver venturi tube out of the top opening.
ACCESSING PRESSURE REGULATOR
To gain access to the pressure regulator, remove two screws on the back. Lift off the hold-down strip and slide the top panel toward the front. If necessary, remove the top drip tray by removing two screws on top.
After reassembly, check that the burner venturi has engaged with the orifice fitting.
© VULCAN-HART, 1997
Loading...