Vulcan Hart K20DLT General Manual

Model K40DLT
Item # C.S.I. Section 11420
S T E A M
KDLT SERIES
DIRECT STEAM FLOOR MOUNTED
TILTING 2⁄3 JACKETED KETTLE
K20DLT 20 gallon true working capacity K40DLT 40 gallon true working capacity K60DLT 60 gallon true working capacity
STANDARD FEATURES
Direct steam, stainless steel, O
tilting steam kettle.
Ellipsoidal bottom kettle liner formed and fully welded O
standard type 316 and type 304 stainless steel exterior.
1
Bar rim ( O
⁄4 x 5⁄8 inch 20 gallons) (3⁄8 x 1 inch 40 gallons and
greater).
Embossed gallon/liter markings. O
50 psi (3.4 kg/cm O
2
) steam jacket rating.
Stainless steel enclosure for steam control valve, self- O
locking tilt mechanism and faucet bracket.
Steam control assembly includes condensate return line O
strainer and safety valve steam trap.
Kettle tilts forward 90° to completely empty. O
Tubular stainless steel legs with flanged feet. O
One year limited parts and labor warranty. O
2
⁄3 jacketed floor mounted
SPECIFICATIONS
Direct steam, stainless steel, 2⁄3 jacketed floor mounted tilting steam kettle, Vulcan-Hart Model No. _____________. Ellipsoidal bottom kettle liner formed and fully welded type 316 and type 304 stainless steel exterior with (1⁄4 x 5⁄8 inch 20 gallons) (3⁄8 x 1 inch 40 gallons and greater) bar rim, embossed gallon/liter markings. 50 psi (3.4 kg/cm2) steam jacket rating. Stainless steel enclosure for steam control valve, self-locking tilt mechanism and faucet bracket. Steam control assembly includes condensate return line strainer and safety valve steam trap. Kettle tilts forward 90° to completely empty. Tubular stainless steel legs with flanged feet.
UL Classified for sanitation in accordance with ANSI/NSF Standard #4. Meets ASME code.
OPTIONS
Two inch compression tangent draw-off valve with perforated strainer. Two inch plug tangent draw-off valve with perforated strainer. Three inch compression tangent draw-off valve with perforated strainer. Correction facility package:
a. Security type tamper resistant fasteners with tack
welds.
b. Stainless steel step cover over draw-off valve with
chain.
Second year extended limited parts and labor warranty.
ACCESSORIES (Packaged & Sold Separately)
Spring assist hinged stainless steel cover with condensate ring and drop down lift handle. Perforated stainless steel basket assembly (single - 20 gal.) (triple - 20, 40 and 60 gallon). Pouring lip strainer. Clean-up kit, includes draw-off brush, clean-up brush and paddle scraper with 40" handle. Stainless steel 48" whip. Solid disk. (12") (18" double jointed) single pantry lead-free faucet. (12") (18" double jointed) double pantry lead-free faucet. Double pantry washdown hose with 16" add-on lead-free faucet with vacuum breaker. Double pantry washdown hose with vacuum breaker. Double pantry pot filler and vacuum breaker.
P.O. Box 696 O Louisville, KY 40201 O Toll-free: 1-800-814-2028 O Local: 502-778-2791 O Quote & Order Fax: 1-800-444-0602
F-37455 (04/10)
S T E A M
DIM “G”
DIM “K”
DIM “D”
DIM “H”
DIM “B”
DIM “A”
DIM “C”
DIM “J”
“L”
“M”
9.1 (230)
13.2 (335)
18.8
(476)
12.0 (305)
“N”
“E”
22.0 (559) (FOR 60 GAL ONLY)
“F”
(ADD 2” FOR
PLUG VALVE)
5.2
(132)
(ADD 2” FOR
OPEN POSITION)
SHOWN WITH OPTIONAL DRAW-OFF VALVE AND SPRING ASSIST LID COVER
KDLT SERIES
DIRECT STEAM FLOOR MOUNTED
TILTING 2⁄3 JACKETED KETTLE
SERVICE CONNECTIONS
Steam supply: 3⁄4" IPS.
Condensate return: 1⁄2" IPS.
TRUE WORKING CAPACITIES (in 4 oz. servings)
80 quarts/20 gallons/76 liters/640 servings 160 quarts/40 gallons/152 liters/1,280 ser vings 240 quarts/60 gallons/228 liters/1,920 servings
NOTE
r%JNFOTJPOTXIJDIMPDBUFUIFBCPWFDPOOFDUJPOTIBWFBUPMFSBODF
of + or -3" (+ or -77 mm).
r*OTUBMMBUJPOPGCBDLáPXQSFWFOUFSTWBDVVNCSFBLFSTBOEPUIFS
specific code requirements is the responsibility of the owner and installer. It is the responsibility of the owner and installer to comply with local codes.
r5IJTBQQMJBODFJTNBOVGBDUVSFEGPSDPNNFSDJBMJOTUBMMBUJPOPOMZ
and is not intended for home use.
DIRECT STEAM DATA
Steam supply to the kettles must:
1. Maintain a steady 10 psi flow under operating conditions.
2. Have a minimum flow (see chart) of dr y steam.
3. Be adequately trapped to provide dry steam. (See ball float trap.)
STEAM FLOW RATE AT 10 PSIG AT THE KETTLE
Fast Boil Medium Boil Slow Boil
lbs/hr kg/hr lbs/hr kg/hr lbs/hr kg/hr
20 gallon 48 22 32 15 24 11
40 gallon 88 40 70 32 44 20
60 gallon 132 60 105 48 66 30
MODEL
K20DLT
K40DLT
K60DLT
P.O. Box 696 O Louisville, KY 40201 O Toll-free: 1-800-814-2028 O Local: 502-778-2791 O Quote & Order Fax: 1-800-444-0602
F-37455 (04/10)
TRUE WORKING
CAPACITY A B C D E F G H J K L M N
20 gallons 21.6 15.2 35.7 37.8 21.3 16 18.4 11.9 20.7 61.3 17.7 28.5 9.9
76 liters 549 386 907 960 543 406 467 302 523 1557 451 726 252
40 gallons 25.8 21.2 36.1 41.8 24 17.7 12.8 7.5 18.6 65.8 12.1 30.3 12.1
152 liters 656 538 917 1062 610 451 325 191 473 1671 308 772 308
60 gallons 29.5 23.9 38.1 45.7 26.8 19.7 15.6 10.9 19.8 72.3 14.9 33 13.8
227 liters 749 607 968 1161 683 500 398 276 503 1836 380 841 352
NOTE: In line with it s policy to co ntinuall y improve its p roduct s, Vulcan re serves t he right to ch ange mate rials and specific ations wi thout noti ce.
Loading...