Vulcan Hart GS60E, GL80E, GT100E, GT125E, GT150E General Manual

Model GL40 E
Item # C.S.I. Section 11420
STEAM
GS, GL & GT SERIES
GAS FULLY JACKETED KETTLES
GL40E 40 gallons 151 liters GS60E 60 gallons 227 liters GL80E 80 gallons 303 liters GT100E 100 gallons 379 liters GT125E 125 gallons 473 liters GT150E 150 gallons 568 liters
STANDARD FEATURES
Kettle fully steam jacketed.
Mounted on stainless steel 2" diameter legs with adjustable ange feet.
Spring assist hinged stainless steel cover with condensate ring and drop down lift handle.
Kettle interior bottom sloped to front for smooth product ow through a mounted, tapered, plug type food product draw-off valve of standard 2" diameter.
Draw-off opening strainer.
Graduated measuring rod.
Faucet bracket.
Vacuum pressure relief valve. 15 PSI relief valve. Low water cut-off control. Pressure limit switch and pressure gauge.
Thermostat with a combination gas control valve and electronic ignition.
One year limited parts and labor warranty.
SPECIFICATIONS
Gas fully jacketed stationary kettle, Vulcan Model No. ________. Kettle is mounted on 2" diameter legs with adjustable anged feet. Spring assist hinged stainless steel cover with condensate ring and drop down lift handle. The dish shaped interior bottom is sloped to the front for a smooth product ow through a mounted, tapered, 2" plug type food product draw-off valve. Draw-off includes opening strainer. Graduated measuring rod. Furnished standard with a 15 PSI relief valve, vacuum relief valve, thermostat with a combination gas control valve and electronic ignition, low water cut-off control and a pressure limit switch and pressure gauge.
CSA design certied. Classied by UL to NSF Std. #4. Meets ASME code.
OPTIONS
Three inch compression tangent draw-off valve with perforated strainer.
Correction facility package. a. Security type fasteners with tack welds. b. Stainless steel step over draw-off valve with chain.
316 stainless steel jacket liner
Second year extended limited parts and labor warranty.
ACCESSORIES (Packaged & Sold Separately)
Perforated stainless steel triple basket assembly.
Clean-up kit, includes draw-off brush, clean-up brush and
paddle scrapper with 40" handle.
Stainless steel 48" whip.
Heat deector shield.
(12") (18" double jointed) single pantry lead-free faucet.
(12") (18" double jointed) double pantry lead-free faucet.
Double pantry washdown hose with 16" add-on lead-free
faucet with vacuum breaker.
Double pantry washdown hose lead-free with vacuum
br e a ker.
Double pantry pot ller lead-free with vacuum breaker.
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F-31643 (04/10)
STEAM
GS, GL & GT SERIES
GAS FULLY JACKETED KETTLES
IMPORTANT:
1. A pressure regulator sized for this unit is included. Natural gas
8.0" W.C. Propane 10.5" W.C.
2. Gas line connecting to unit must be 3⁄4" or larger. If exible connectors are used, the inside diameter must be at least the same as the 3⁄4" iron pipe and rated for the correct gas input.
3. Requires 120 volt, 60 Hz, 1 phase electrical connection. 3 amp total draw.
4. An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. When writing refer to NFPA No. 96.
5. These units are manufactured for installation in accordance with ANSZ223.1a (latest edition), National Fuel Gas Code. Copies may be obtained from the American Gas Association. 1515 Wilson Blvd., Arlington, VA 22209.
6. Equipment Clearance: Combustible Non-Combustible
Rear 2" 0" Right 0" 0" Left 0" 0"
SERVICE CONNECTIONS:
Gas Supply: 3⁄4" NPT, 6" AFF, Volume per schedule.
Electric Connection: 120-1 Circuit, 0.3 K W, 16 AFF.
Water: Faucet location.
Add 2" to “C” & “D” for 3" compression
1
tangent draw-off valve.
NOTE:
• Dimensionswhichlocatetheaboveconnectionshaveatolerance
of + or -3" (+ or -75 mm).
• Installationofbackowpreventers,vacuumbreakersandother
specic code requirements is the responsibility of the owner and installer. It is the responsibility of the owner and installer to comply with local codes.
• Plasticdrainsarenotrecommendedduetoinherentlimited
temperatures of the plastic.
• Thisapplianceismanufacturedforcommercialinstallationonly
and is not intended for home use.
BRIMFUL CAPACITIES:
MODEL GALLONS QUARTS LITERS 4 OZ. SVGS.
GL40E 40 160 151 1280
GS60E 60 240 227 1920
GL80E 80 320 303 2560
GT100E 100 400 379 3200
GT125E 125 500 473 4000
GT150E 150 600 568 4800
MODEL CAPACIT Y
INPUT A B C D E F G
GL40E 40 gallons, 151 liters 105,000 29 (737) 48 (1219) 41 (1041) 38 (965) 14 (356) 40 (1016) 71 (1803)
GS60E 60 gallons, 227 liters 135,000 361⁄2 (927) 581⁄2 (1486) 48 (1219) 44 (1118) 17 (432) 39 (991) 78 (1981)
GL80E 80 gallons, 303 liters 135,000 361⁄2 (927) 581⁄2 (1486) 48 (1219) 44 (1118) 17 (432) 44 (1118) 83 (2108)
GT100E 100 gallons, 379 liters 135,000 361⁄2 (927) 581⁄2 (1486) 48 (1219) 44 (1118) 17 (432) 49 (1245) 88 (2235)
GT125E 125 gallons, 473 liters 135,000 361⁄2 (927) 581⁄2 (1486) 48 (1219) 44 (1118) 17 (432) 56 (1422) 95 (2413)
GT150E 150 gallons, 568 liters 135,000 361⁄2 (927) 581⁄2 (1486) 48 (1219) 44 (1118) 17 (432) 621/2 (1587) 101 (2565)
BTU/HR.
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F-31643 (04/10)
NOTE: In line w ith its p olicy to continually imp rove its products, Vulcan rese rves the right to change m ateri als and s pecicatio ns without noti ce.