Vulcan-Hart C24EA3, C24EA5 Specifications

Item # _____________________________
C.S.I. Section 11420
ELECTRIC COUNTER CONVECTION STEAMER
C24EA3 3 pan capacity
C24EA5 5 pan capacity
STANDARD FEATURES
Stainless steel exterior and cooking compartment with coved interior corners.
Leveling feet.
Manual control with 60 minute timer.
High output stainless steel steam generator with manual drain
Smart Drain System (timed drain) with PowerFlush.
Heavy duty door and door latch mechanisms.
Shipped for 208/60-50/3 electrical service. Can be eld con-
verted to 208/60-50/1 and 240/60-50/3 and 240/60-50/1.
Split water line connection. 11/2" NPT drain connection.
One year limited parts and labor warranty.
A2780
ISO9001
Vulcan-Hart Co.
MODEL: C24EA SERIES Electric Counter Convection Steamer
Shown on optional stand with
extra set of pan slides and pans
SPECIFICATIONS:
Single compartment electric convection steamer, Vulcan-Hart Model No. (C24EA3) (C24EA5). Stainless steel exterior and cooking compartment with coved interior corners. Manual control with 60 minute timer. High output stainless steel steam generator with manual drain and Smart Drain System (timed drain) with PowerFlush. Heavy duty door and door latch mechanisms. Shipped for 208/60-50/3 electrical service. Can be eld converted to 208/60-50/1 and 240/60-50/3 and 240/60-50/1. Split water line connection. 11/2" NPT drain con­nection.
Exterior dimensions: 3 pan: 24"w x 33"d x 191/2"h. 5 pan: 24"w x 33"d x 26"h.
OPTIONS
Professional Control Package includes:
Superheated Steam System
Staged Fill
Lighted power switch with cook and ready lights
Auto drain with Smart Drain System (timed drain) with
PowerFlush
Timer 60 minute 60 cycle (50 cycle x 1.2) with Constant
Steam Setting
Cord strain relief
Second year extended limited parts and labor warranty
contract.
ACCESSORIES
4" counter legs.
12" x 20" stainless steel pans:
- 1" deep (solid) (perforated) Qty.____.
- 21/2" deep (solid) (perforated) Qty.____.
- 4" deep (solid) (perforated) Qty.____.
Stainless steel pan cover. Qty.____.
Open leg stand.
28" open leg stand with pan slides 24"w x 28"h.
34" open leg stand with pan slides 24"w x 34"h.
Set of two universal pan slides for open leg stand.
Stand sliding shelf.
Stacking kit for two units with hardware, counter mount.
Floor legs, 6".
Floor caster, 6".
Pull-out 12" x 20" sliding shelf (cooking compartment).
Qty. ____.
Cord and plug set.
Water treatment system.
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
F-32627 (06-08)
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
Printed On Recycled Paper
ELECTRIC COUNTER CONVECTION STEAMER
SERVICE CONNECTIONS:
ELECTRICAL CONNECTIONS: Field Wire Electrical Connection 11/4" (32 mm) K.O. service entrance.
DRAIN: 11/2" IPS piped to open drain. No solid connections. 60" length before open air gap opening and not more than two bends or elbows.
GENERATOR WATER SUPPLY: 3/4" (19 mm) hose bib to generator, ow rate .5 gpm @ minimum 25 to maximum 50 psi. (170-345 kPa).
CONDENSING WATER SUPPLY: 3/4" (19 mm) hose bib to condenser, ow rate .5 gpm @ minimum 25 to maximum 50 psi. (170-345 kPa).
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable for steam generation. Your water supply must be within these general guidelines:
SUPPLY PRESSURE 20 - 60 psig HARDNESS* less than 3 grains SILICA less than 13 ppm TOTAL CHLORIDE less than 4.0 ppm pH RANGE 7-8 UN-DISSOLVED SOLIDS less than 5 microns * 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. Water supplies vary from state to state and from locations within a state. Therefore it is necessary that the local water treatment specialist be consulted before the installation of any steam generating equipment.
NOTE:
• Dimensionswhichlocate the aboveconnections have a
tolerance of + or -3" (+ or -75 mm).
• Installation of backow preventers, vacuum breakers and other specic code requirements is the responsibility of the owner and installer. It is the responsibility of the owner and installer to comply with local codes.
• Plastic drains are not recommended due to inherent limited temperatures of the plastic. Boiler purge tempera­tures may exceed 180°F. The installer may be required to provide means to reduce boiler purge water temperature to be that of the condensate temperature of 140°F or less.
• Thisapplianceismanufacturedforcommercialinstallation
only and is not intended for home use.
NOTE: 208 volt, 3 phase is an unbalance load, and amp listed is the max on any leg. Refer to the I/O manual for further details.
BASIC CONTROL PACKAGE
MODEL PH 208V 240V 480V KW AMP KW AMP KW AMP
C24EA3 1 8.5 41 8.5 36 3 8.5 27 8.5 21 8.5 11 C24EA5 1 15 72 15 63 3 15 42 15 36 15 18
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and specications without notice.
F-32627 (06-08)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
PAN CAPACITY
MODEL 1" 21/2" 4" 6"
C24EA3 6 3 2 1 C24EA5 10 5 3 2
PROFESSIONAL CONTROL PACKAGE
MODEL PH 208V 240V 480V KW AMP KW AMP KW AMP
C24EA3 1 9.25 45 9.25 39 3 9.25 29 9.25 23 9.25 12 C24EA5 1 15.75 76 15.75 66 3 15.75 44 15.75 38 15.75 19