Vulcan VWT18 User Manual

Mod el VWT12
Item # C.S.I. Section 11420
HEAVY DUTY COOKING
HEAVY DUTY GAS RANGE
MODULAR SPREADERS
VWT12
12" Modular Spreader
VWT18
18" Modular Spreader
VWT24
24" Modular Spreader
VWT36
36" Modular Spreader
STANDARD FEATURES
■ Stainless steel work surface, front, front top ledge, sides, base, and stub back
■ 11⁄4" diameter front gas manifold
■ 4" stainless steel stub riser
■ One year limited parts and labor warranty
OPTIONAL FE ATURES (Factory Installed)
Rear gas connections 11⁄4" (18", 24" 36" models)
Cap and cover front manifold
4" adjustable feet
Condiment type rail for 24" and 36" models
3⁄4", 1", or 11⁄4" gas pressure regulator (specify gas type – pack loose)
SPECIFICATIONS
Full body work top spreader, Vulcan Model No. VWT12 (12" wide) and VWT18 (18" wide) or VWT24 (24" wide) and VWT36 (36" wide). Full body work top spreader of 20 gauge stainless steel with 16 gauge stainless steel work surface, and 4" high stub riser. Stainless steel work surface, front top ledge, sides, base, and stub back 11⁄4" diameter front gas manifold.
Exterior Dimensions:
363⁄4"d x 12"w x 91⁄4"h
ACCESSORIES (Packaged & Sold Separately)
Banking strip
10", 22", or 34" high back risers (no shelf)
22" single deck solid or o-thru high shelf risers
34" double deck solid or o-thru high shelf risers
Flexible gas hose with quick disconnect and restraining device
Common plate rails (starting at 36" length)
Common condiment type, telescoping plate rails (starting at 24" length)
a divisi on of IT W Food Equ ipme nt Group L LC
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F37428 (08/11)
HEAVY DUTY COOKING
HEAVY DUTY GAS RANGE
INSTALLATION INSTRUCTIONS
1. A properly sized gas pressure regulator suitable for battery or single unit application must be furnished and installed. Natural gas
6.0" W.C., propane gas 10.0" W.C.
2. An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269, www.NFPA.org. When writing, refer to NFPA No. 96.
3. These units are manufactured for installation in accordance with ANSZ223.1A (latest edition), National Fuel Gas Code. Copies may be obtained from The American Gas Association, 400 N Capitol St. NW, Washington, DC 20001, www.AGA .org.
4. Clearances Rear Sides Combustible 10" 10" Non-combustible 0" 0"
MODULAR SPREADERS
5. For proper combustion, install equipment on adjustable legs or casters. On curb or platform, allow 31⁄2" front overhang. Toe base with leveling bolts are required for curb installation. Specify when ordering.
6. Cannot be batteried with GH series equipment.
7. This appliance is manufactured for commercial installation only and is not intended for home use.
NOTE: In line with its policy to continually improve its product, Vulcan reserves the right to change materials and specications without notice.
Specify type of gas when ordering.
Specify altitude when above 2,00 0 feet.
MODEL
NUMBER
VW T12 12" Wide Modular Spreader 200 / 91
VW T18 18" Wide Modular Spreader 210 / 96
VWT24 24" Wide Modular Spreader 276 / 126
VWT36 36" Wide Modular Spreader 520 / 263
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F37428 (08/11)
NOTE: In line with its policy to con tinua lly improve its pr oduct s, Vulca n rese rves th e right to change materi als and speci cati ons without not ice.
DESCRIPTION
a divisi on of IT W Food Equ ipme nt Group L LC
SHIPPING WEIGHT
LBS / KG
Loading...