Vulcan VFRY18 User Manual

VFRY18
Item # C.S.I. Section 11420
HEAVY DUTY COOKING
HEAVY DUTY GAS RANGE
RANGE MATCH FRYERS
VFRY18
18" Single Fryer
STANDARD FEATURES
Stainless steel front, front top ledge, sides, fry tank, base, and stub back
1
⁄4" Diameter front gas manifold
1
3
⁄4" Rear gas connection (capped)
120,000 BTU/hr. input Four heat exchanger tubes per fryer Solid State behind the door controls Hi-limit shut off Combination gas shut-off valve and pilot ignition system Drain valve interlock switch Electronic ignition (120 volt/60/1) (NEMA 5-15P) Drawn 18 gauge stainless steel lter pan (for lter models) Boil Out ByPass™ 6" adjustable stainless steel legs One year limited parts and labor warranty & 5 year limited fry
tank warranty
SPECIFICATIONS
Heavy Duty range match fryers, Vulcan model No. ___VFRY18 (Single Fryer). Fryers with solid state, behind the door controls (120V/60/1), electronic pilot ignition. Four heat exchanger tubes and burners per fryer. Hi-limit shut-off and combination gas shut-off valve. Drain valve interlock switch. Stainless steel front, font top ledge, sides, fry tank (12 year tank warranty), base, and stub back. Units are standard on 6" legs. 1
3
⁄4" rear gas connection, capped. 120,000 BTU’s/hr. input.
and
1
⁄4" front gas manifold,
Requires 120 volt, 60 Hz, 1 phase power supply. (NEMA 5-15P)
Optional Features (Factory Installed)
Cap and cover front manifold Stainless steel tank cover, doubles as work-top surface 10" High Side Splash (removable) Flanged Feet Set of 4 casters, 6" high (two locking)
ACCESSORIES (Packaged & Sold Separately)
Extra set of twin Baskets Single Bulk Baskets Common condiment type, telescoping plate rails (starting at
24" length) 10", 22", or 34" high back risers (no shelf ) 22" single deck solid or flo-thru high shelf risers 34" double deck solid or flo-thru high shelf risers Flexible gas hose with quick disconnect & restraining device
a divisi on of IT W Food Equ ipme nt Group L LC
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F45311 (06/10)
INSTALLATION INSTRUCTIONS
18"
HEAVY DUTY COOKING
HEAVY DUTY GAS RANGE
RANGE MATCH FRYERS
A combination valve with pressure regulator is provided with this 1. unit. Natural Gas: 4.0" (102mm) W.C. Propane Gas: 10.0" (254mm) W.C.
An adequate ventilation system is required for commercial cooking 2. equipment. Information may be obtained by writing to the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA
02269. When writing refer to NFPA No.96.
These units are manufactured for installation in accordance with 3. ANSZ223.1A (latest edition), National Fuel Gas Code. Copies may be obtained from The American Gas Association, 400 N Capitol St., N.W., Washington, DC 20001, www.AGA.org.
For proper combustion, install equipment on adjustable legs or 4. casters. On curb or platform, all 3 with leveling bolts are required for curb installation. Specify when ordering.
1
⁄2" front overhang. Toe base
5. Clearances Rear Sides Combustible 10" 10" Noncombustible 0" 0" Open Top Models 16" 16"
Cannot be batteried with GH series equipment.6.
This appliance is manufactured for commercial installation only 7. and is not intended for home use.
NOTE:
In line with its policy to continually improve its product, Vulcan
reserves the right to change materials and specication without notice.
Specify type of gas when ordering.
Specify altitude when above 2,00 0 feet.
MODEL
NUMBER
VFRY18 18" Wide, Range Match, Heavy-Duty Fryer. 120,000 215 / 98
This appliance is manufactured for commercial use only and is not intended for home use.
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F45311 (06/10)
NOTE: In line with its policy to con tinua lly improve its pr oduct s, Vulca n rese rves th e right to change materi als and speci cati ons without not ice.
DESCRIPTION
a divisi on of IT W Food Equ ipme nt Group L LC
TOTAL INPUT
BTU / HR
SHIPPING WEIGHT
LBS / KG
Loading...