Vulcan VF1 Installation Manual

INSTALLATION &
OPERATION MANUAL
VF SERIES ELECTRIC FRYERS
MODEL
VF1 ML-52913 VMF1 ML-52914 VF2 ML-52915 VMF2 ML-52916 VF90 ML-52917 VFD90 ML-52532 VF1D ML-52538 VMF1D ML-52539 VF2D ML-52542 VMF2D ML-52543
VF1
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791
FORM 30916 (1-95) (Formerly F-114555 & F-114556)
Installation, Operation and Care of
MODELS VF1, VMF1, VF2, VMF2, VF1D,
VMF1D, VF2D & VMF2D
ELECTRIC FRYERS
SAVE THESE INSTRUCTIONS FOR FUTURE USE
GENERAL
Standard features include stainless steel fry tank and front, a high limit device, twin baskets, and a lift­out fry tank (20" wide models only) which is easily removed for cleaning.
VF1, VF2, VF1D and VF2D floor model fryers are equipped with 6" adjustable legs. They may be ordered without legs for installation on a masonry base. The fryers also can be supplied with a 4" toe base in place of legs as an optional extra.
Optional features include extra fry tanks, a large single basket supplied in place of twin baskets, syphon and strainer bags, casters (floor models only), stainless steel fry tank cover, and extra sets of twin baskets or single baskets. Stainless steel side(s) and back are also available optionally.
AUTOMATIC
BASKET MELT
MODEL WIDTH / STYLE CONTROLS LIFT CYCLE
VF1 20" Floor model Mechanical Opt. Opt. VMF1 20" Countertop Mechanical Opt. Opt. VF2 24" Floor model Mechanical Opt. Opt. VMF2 24" Countertop Mechanical Opt. Opt. VF1D 20" Floor model Solid State Opt. Std. VMF1D 20" Countertop Solid State Opt. Std. VF2D 24" Floor model Solid State Opt. Std. VMF2D 24" Countertop Solid State Opt. Std. VF90/VFD90 20" Frymate N/A N/A N/A
The VF90 and VFD90 Frymate Work Stations may be installed next to any of the VF Series Fryers. The top draining section has a lift-out screen and center drain into a 3-quart, slide-out drain pan. The interior of the cabinet has storage space for 4 standard #200 pans in drawer-type, non-tilt pan slides. Pans are not supplied with the Frymate.
The Frymate is equipped with 6" adjustable legs. It may be ordered without legs for installation on a masonry base, or with a 4" toe base in place of legs as an optional extra.
— 2 —
INSTALLATION
Before installing the fryer, verify that the electrical supply agrees with the specifications on the fryer data plate which is located on the inside of the door panel on floor model fryers and on the lower front cover on countertop models.
UNPACKING
Immediately after unpacking the fryer, check it for possible shipping damage. If the fryer is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
Do not use the door or its handle to lift or move the fryer.
LOCATION
The fryer may be installed at 0" clearance from the back or side walls. The fryer must be installed at least 16" away from any open top flame appliance. Position the fryer for easy accessibility for service.
INSTALLATION CODES AND STANDARDS
Vulcan fryers must be installed in accordance with:
In the United States
1. State and local codes.
2. National Electrical Code ANSI/NFPA No. 70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
3. NFPA Standard #96.
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
Position the fryer in its final location. Select the size and type of wire in accordance with National Electrical Code suitable for carrying the fryer's rated amps and voltage. Use wires suitable for 75°C on fryers carrying more than 80 amps.
— 3 —
1. Bring conduit containing the proper supply wire to the fryer.
On VF1/VMF1 and VF1D/VMF1D, bring the conduit in through the clearance hole in the back and terminate on the terminal block housing mounted in the back of the breaker box.
On VF2 and VF2D, terminate the field supply conduit on the corner of the bottom floor and bring the supply leads into the breaker box through the removable channel mounted to the right side.
On VMF2 and VMF2D, bring the conduit through the opening in the bottom toward the front of the fryer.
2. Connect the supply leads to the field terminal block and the green grounding lead to the labeled ground lug.
Fryers wired for 3-phase service may be changed to 1-phase or vice versa by relocating two wires on the terminal block as shown on the wiring diagram and the schematic decal which is attached to the fryer.
ELECTRICAL DATA CHART
TOTAL 3-PHASE LOADING NOMINAL AMPS PER LINE WIRE
MODEL K.W. KW PER PHASE 3 PHASE 1 PHASE
CONN. 208, 240 & 480 V. 208 V. 240 V. 480 V. 208 240 480
X-Y Y-Z X-Z X Y Z X Y Z X Y Z V. V. V.
VF1/VMF1, VF1D/VMF1D VF2/VMF2, VF2D/VMF2D
12 3.8 3.8 4.2 34 33 34 29 28 29 15 14 15 58 50 25
21.0 5.25 10.5 5.25 44 66 66 38 57 57 20 30 30 101 88 44
LEVELING
Level floor model fryers. Place a carpenter's level on top of the fryer and turn the adjustable legs to level fryer front-to-back and side-to-side.
Countertop models must be placed on a level surface.
BEFORE FIRST USE
Clean fryer thoroughly, following procedures described in this manual under CLEANING — WEEKLY OR AS REQUIRED. Clean all fryer accessories. Rinse all parts thoroughly and wipe dry.
Lightly season backsplash area to avoid possible surface corrosion. With a soft, lint-free cloth, apply a thin layer of cooking oil over entire backsplash area. This should also be done after every cleaning.