STEAM
STATIONARY 2⁄3 JACKETED KETTLE
Model K40G L
SPECIFICATIONS
Gas self-contained, stainless steel fully insulated, 2⁄3 jacketed oor mounted steam kettle Ellipsoidal bottom kettle liner
formed and fully welded type 316 and type 304 stainless steel
exterior with (1⁄4 x 5⁄8 inch 20 gallons) (3⁄8 x 1 inch 40 gallons
and greater) heavy bar rim, embossed gallon/liter markings.
50 psi (3.4 kg/cm2) steam jacket rating. Spring assist hinged
stainless steel cover with condensate ring and drop down lift
handle. Stainless steel splash proof enclosure for controls and
faucet bracket. Controls include a power switch, power “on”
light, solid state temperature control with graduated warm,
simmer and boil setting, vacuum/pressure gauge, pressure
relief valve, low water light and low water shut-off. Gas control
with combination gas valve, ame failure and gas type is eld
convertible. High efciency Power Burner Heating System
(64% to 68% efciency). Tubular stainless steel legs with
removable section and anged feet. Steam jacket permanently
lled with treated, distilled water. 110-120V, 50-60 Hz, 5A, with
6 foot cord and three-prong grounding plug.
UL Certied to ANSI Z83.11/CSA 1.8. Certied to NSF Standard
#4. Meets ASME.
SPAN GAS TECHNOLOGY ENABLES FIELD ADJUSTABLE TO
PROPA NE GAS .
Item # C.S.I. Section 11420
KGL SERIES
GAS FLOOR MOUNTED
K20GL 100,000 BTU/hr., 20 gallon true working capacity
K40G L 100,000 BTU/hr., 40 gallon true working capacity
K60GL 100,000 BTU/hr., 60 gallon true working capacity
STANDARD FEATURES
■ Gas self-contained, stainless steel, 2⁄3 jacketed oor
mounted stationary steam kettle.
■ Ellipsoidal bottom kettle liner formed and fully welded
standard type 316 and type 304 stainless steel exterior.
■ Heavy bar rim (1⁄4 x 5⁄8 inch 20 gallons) (3⁄8 x 1 inch 40
gallons and greater).
■ Embossed gallon/liter markings.
■ Faucet bracket.
■ 50 psi (3.4 kg/cm2) steam jacket rating.
■ Spring assist hinged stainless steel cover with condensate
ring and drop down lift handle.
■ Two inch compression tangent draw-off valve with
perforated strainer.
■ Tubular stainless steel legs with anged feet.
■ Stainless steel enclosure for “water resistant” controls.
■ Controls include a power switch, power “on” light, solid
state temperature control, vacuum/pressure gauge, pressure relief valve, low water light and low water shut-off.
■ Elevation from sea level to 8,999 feet standard, for higher
elevation consult factory.
■ One year limited parts and labor warranty.
OPTIONS
Two inch bolt on plug draw-off valve with perforated
strainer.
Three inch bolt on compression tangent draw-off valve
with perforated strainer increases height of kettle.
Correction facility package:
a. Security type fasteners with tack welds.
b. Stainless steel cover over draw-off valve with chain.
Stainless steel protector for the draw-off valve with chain.
Reinforced pivot assembly for spring assist cover.
Heavy duty 14 gauge welded cover twin bar welded
handles, NOT spring assist.
Second year extended limited parts and labor warranty.
ACCESSORIES (Packaged & Sold Separately)
Perforated stainless steel basket assembly (single – 20
gallon) (triple – 20 through 60 gallon).
Clean-up kit, includes draw-off brush, clean-up brush and
paddle scrapper with 40" handle.
Stainless steel 48" whip.
Non-perfortaed strainer for draw-off valve.
(12") (18" double jointed) single pantry lead-free faucet.
(12") (18" double jointed) double pantry lead-free faucet.
Double pantry washdown hose with 16" add-on lead-free
faucet with vacuum breaker.
Double pantry washdown hose lead-free with vacuum
br e a ker.
Double pantry pot ller lead-free with vacuum breaker.
a divisi on of IT W Food Equ ipment Group LLC
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F37460 (01/15)
STEAM
KGL SERIES
GAS FLOOR MOUNTED
STATIONARY 2⁄3 JACKETED KETTLE
SERVICE CONNECTIONS
Electrical Connection: 110-120V, 50-60 Hz, 5A, with 6 foot
cord and three-prong grounding plug.
Gas Connection: 1⁄2" NPT supply line required.
Water Connection: For faucet option only.
EMBOSSED GALLON/LITER MARKINGS
20-GALLON 40-GALLON 60-GALLON
20 - 76 40 - 151 60- 227
18 - 68 35 - 132 55 - 209
16 - 61 30 - 114 50 - 189
14 - 53 25 - 95 45 - 171
12 - 46 20 - 76 40 - 151
10 - 38 15 - 57 35 - 132
25 - 95
20 - 76
TRUE WORKING CAPACITIES (in 4 oz. servings)
80 quarts/20 gallons/76 liters/640 servings
120 quarts/40 gallons/152 liters/1,280 servings
160 quarts/60 gallons/228 liters/1,920 servings
NOTE:
• Dimensions which locate the above connections have a tolerance
of + or -3" (+ or -75mm). Normal dimensions are in inches.
Dimensions in ( ) are in millimeters.
• Installation of backow preventers, vacuum breakers and other
specic code requirements is the responsibility of the owner and
installer. It is the responsibility of the owner and installer to comply
with local codes.
• Do not use plastic drains.
• Do not connect this unit to a ground-fault circuit-interrupter (GFCI)
125-volt, single-phase, 15- and 20-ampere receptacle. Electronic
burner ignition systems are prone to nuisance tripping and
possible ignition failure.
• This appliance is manufactured for commercial installation only
and is not intended for home use.
TRUE
WORKING
MODEL
K20GL
K40GL
K60GL
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F37460 (01/15)
CAPACI T Y A B C D E F G H J K L M N P
20 gallons 21.6 15.2 36.8 32.7 18.6 15.6 19.5 6.4 17 32.6 19.2 20.9 9.5 14.6
76 liters 549 386 935 8 31 472 396 495 163 432 828 488 531 241 371
40 gallons 26 21. 2 39.2 36.7 19.8 17.7 5 16 6.4 18 69 15.6 23 11. 6 14.1
152 l iters 660 538 996 932 503 451 406 163 457 1753 396 584 295 358
60 gallons 29.5 24.2 39.5 40.9 21.7 19.75 16.6 6 19.9 76.6 16 .2 26.5 13. 8 13.7
227 liters 749 615 100 3 1039 551 502 422 152 505 1946 411 673 3 51 348
a divisi on of IT W Food Equ ipment Group LLC
NOTE: In line w ith its policy to co ntinua lly imp rove its pr oduct s, Vulca n reser ves the right to c hange materia ls and sp ecic ation s withou t notice.