Item # __________________________
C.S.I. Section 11420
HEG SERIES
HEAVY DUTY ELECTRIC GRIDDLES
■■ HEG24R 24"w x 18"d griddle plate
■■ HEG36S 36"w x 18"d griddle plate
■■ HEG36D 36"w x 24"d griddle plate
■■ HEG48D 48"w x 24"d griddle plate
■■ HEG60D 60"w x 24"d griddle plate
■■ HEG72D 72"w x 24"d griddle plate
STANDARD FEATURES
■ Stainless steel front, sides and 4" adjustable legs.
1
■
⁄2" thick polished steel griddle plate.
■ One solid sheathed tubular incoloy heating element, thermostat and cycling light per each 12" griddle width. Thermostat
adjusts from 200° to 450°F.
■ Stainless steel splash shield is 4" high at the back and tapers
down to 2" at the front.
1
■ 3
⁄8" wide grease trough empties into large capacity grease
drawer. 72" wide model has two grease drawers. "R" model
has a front and rear grease trough. "S" & "D" models have a
front grease trough.
■ Requires 208/240 volt, 60 Hz, 1 or 3 phase power supply.
■ One year limited parts and labor warranty.
Vulcan-Hart Co.
ISO9001
A2780
MODEL: HEG SERIES
SPECIFICATIONS:
Heavy duty electric griddle, Vulcan-Hart Model No. ________.
Stainless steel front, sides and 4" adjustable legs. _____"w x
_____"d x
1
⁄2" thick polished steel griddle plate. One solid sheathed
tubular incoloy heating element, thermostat and cycling light per
each 12" griddle width. Thermostat adjusts from 200° to 450°F.
Stainless steel splash shield is 4" high at the back and tapers
down to 2" in the front. 3
1
⁄8" wide grease trough empties into large
capacity grease drawer. Requires 208 or 240 volt, 60 Hz, 1 or 3
phase power supply.
NSF listed. U L listed. U L listed to Canadian safety standards.
SPECIFY VOLTAGE AND PHASE WHEN ORDERING.
OPTIONS
■■ Stainless steel stand with undershelf and casters, two
locking.
■■ 480 volt, 60 Hz, 3 phase.
■■ Second year extended limited parts and labor warranty.
Heavy Duty Electric Griddles
F-31616 (10-03)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
ELECTRICAL CHARACTERISTICS
STANDARD VOLTAGES—208 VOLTS OR 240 VOLTS 60 Hz.—SINGLE OR THREE PHASE
OPTIONAL VOLTAGE—480 VOLTS 60 Hz.—THREE PHASE ONLY
TOTAL TOTAL 3 PHASE LOADING NOMINAL AMPS PER LINE WIRE PER CONN.*
MODEL CONN. KW KW PER PHASE 3 PHASE 1 PHASE
NO. KW PER PER CONN.* 208 VOLT 240 VOLT 480 VOLT 208 240
CONN.* X-Y Y-Z X-Z X Y Z X Y Z X Y Z VOLT VOLT
HEG24R 8.0 8.0 4.0 0.0 4.0 25.5 14.4 14.4 28.9 16.7 16.7 14.4 8.3 8.3 28.8 33.3
HEG36S 12.0 12.0 4.0 4.0 4.0 33.3 33.3 33.3 28.9 28.9 28.9 14.4 14.4 14.4 57.7 50.0
HEG36D 16.2 16.2 5.4 5.4 5.4 45.0 45.0 45.0 39.0 39.0 39.0 19.5 19.5 19.5 77.9 67.5
HEG48D 21.6 21.6 10.8 5.4 5.4 68.7 68.7 45.2 59.5 59.5 39.0 29.8 29.8 19.5 103.9 90.0
HEG60D* 27
HEG72D* 32.4
*Model HEG60D & HEG72D require two separate electrical connections and services.
16.2 5.4 5.4 5.4 45.0 45.0 45.0 39.0 39.0 39.0 19.5 19.5 19.5 77.9 67.5
10.8 5.4 0 5.4 45.0 26.0 26.0 39.0 22.5 22.5 19.5 11.3 11.3 51.9 45.0
16.2 5.4 5.4 5.4 45.0 45.0 45.0 39.0 39.0 39.0 19.5 19.5 19.5 77.9 67.5
16.2 5.4 5.4 5.4 45.0 45.0 45.0 39.0 39.0 39.0 19.5 19.5 19.5 77.9 67.5
HEG24R
HEG36D