Shown on accessory stand with
extra set of pan slides and pans
Item # C.S.I. Section 11420
STEAM
C24EA-LWE SERIES
ELECTRIC COUNTER CONVECTION STEAMER
C24E A3- LW 3 pan capacity professional controls
C24EA5-LW 5 pan capacity professional controls
STANDARD FEATURES
■ Stainless steel exterior and cooking compartment with coved
interior corners.
■ Leveling feet.
■ Manual control with 60 minute timer, 60 cycle (50 cycle x 1.2).
■ High output stainless steel steam generator with Smart Drain
System (timed drain) with PowerFlush.
■ Heavy duty door and door latch mechanisms with gasket guard.
■ Shipped for 208/60-50/3 electrical service. Can be eld converted
to 240/60-50/3.
■ Split water line connection. 11⁄2" NPT drain connection.
■ Energy and water saving steam generation
■ Staged Fill
■ Lighted power switch with cook and ready lights
■ Timer 60 minute 60 cycle (50 cycle x 1.2) with Constant Steam
Setting
■ Cord strain relief
■ One year limited parts and labor warranty.
OPTIONS
Second year extended limited parts and labor warranty contract.
SPECIFICATIONS
Single compartment electric convection steamer. Stainless steel
exterior and cooking compar tment with coved interior corners.
Manual control with 60 minute timer. High output stainless
steel steam generator with Smar t Drain System (timed drain)
with PowerFlush. Heavy duty door and door latch mechanisms.
Shipped for 208/60-50/3 electrical service. Can be eld converted
to 240/60-50/3. Split water line connection. 11⁄2" NPT drain
connection.
Exterior Dimensions:
3 pan: 24"w x 33"d x 191⁄2"h.
5 pan: 24"w x 33"d x 26"h.
UL listed. Classied by UL to NSF Standard #4. Meets ENERGY
STA R® performance levels.
ACCESSORIES (Packaged & Sold Separately)
4" adjustable counter legs.
Open leg 24"w stand.
28"h
34"h
Set of two universal pan slides for open leg stand
Stand sliding shelf
Casters
Stacking kit for two units with hardware, counter mount or on 15"
and 28" stands.
Note: Only a single 3 or 5 pan steamer or two 3 pan steamers can
be stacked on a 28"h stand. Single 3 or 5 pan steamers only on a
34"h stand. Any combination of two steamers can be stacked on
a 15" stand.
15" open leg stand
Casters
Single point electrical connection kit for stacked units,
3-phase only.
Pull-out 12" x 20" sliding rack (cooking compartment). Qty. ____.
Cord and plug set, 208-240v/3ph (rated to 40 amps) 72":
ANGLED PLUG HBL8462C NEMA 15-60 (CORDPLG-3PAN3P).
Cord and plug set, 208-240v/3ph (rated to 55 amps) 72":
ANGLED PLUG HBL8462C NEMA 15-60 (CORDPLG-5PAN3P).
Cord and plug set, 480v/3ph (rated to 30 amps) 72":
STRAIGHT PLUG HBL2731 NEMA L16-30 (CORDPLG-5PAN480).
Flex stainless steel water connection 72" 3⁄4" female NSHT on
both ends, 2 required and 3 with lter system. Qty. ____.
Water treatment system.
a divisi on of IT W Food Equ ipment Group LLC
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F47126 (01/15)
STEAM
C24EA-LWE SERIES
ELECTRIC COUNTER CONVECTION STEAMER
SERVICE CONNECTIONS:
ELECTRICAL CONNECTIONS: Field Wire Electrical
Connection 11⁄4" (32 mm) K.O. service entrance.
DRAIN: 11⁄2" IPS piped to open drain. No solid connections.
60" length before open air gap opening and not more than two
bends or elbows. Note: Stacked units must have independent
drains, do not connect together.
GENERATOR WATER SUPPLY: 3⁄4" (19 mm) male NSHT to
generator, ow rate 4 gpm @ minimum 20 to maximum 60 psi.
(138-414 kPa) treated water.
CONDENSING WATER SUPPLY: 3⁄4" (19 mm) male NSHT to
NOTE:
• Dimensions which locate the above connections have a tolerance
of + or -3" (+ or -75 mm).
• Installation of backow preventers, vacuum breakers and other
specic code requirements is the responsibility of the owner and
installer. It is the responsibility of the owner and installer to comply
with local codes.
• Do not use plastic drains.
• This appliance is manufactured for commercial installation only
and is not intended for home use.
condenser, ow rate 4 gpm @ minimum 20 to maximum 60 psi.
(138-414 kPa) untreated water.
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is
suitable for steam generation. Your water supply must be within these
MODEL 1" 21⁄2" 4" 6"
C24EA3 6 3 2 1
C24EA5 10 5 3 2
PAN CAPACITY
general guidelines:
SUPPLY PRESSURE 20 - 60 psig
HARDNESS* less than 3 grains
SILICA less than 13 ppm
TOTAL CHLORINE less than 0.1 ppm
pH RANGE 7-8
UN-DISSOLVED SOLIDS less than 5 microns
* 17.1 ppm = 1 grain of hardness
C24E A3-LW 3 8.5 27 8.5 21 8.5 10
C24EA5-LW 3 15 48 15 36 15 18
PROFESSIONAL CONTROL PACKAGE
208V 240V 480V
MODEL PH
KW AMP KW AMP KW AMP
Other factors affecting steam generation are iron content, amount
of chloridation and dissolved gases. Water supplies vary from state
to state and from locations within a state. Therefore it is necessary
that the local water treatment specialist be consulted before the
installation of any steam generating equipment.
NOTE: 208 volt, 3 phase is an unbalance load, and amp listed is the max on any leg. Refer to the I/O manual for further details.
[137]
DRAIN
TREATED WATER
ELECTRIC SERVICE
7-7/8
[200]
UNTREATED WATER
3
[76]
DELIME PORT
13
[329]
1-1/4
[31]
3 PAN
19-1/2
[501]
5 PAN
26
5-5/8
[663]
[143]
a divisi on of IT W Food Equ ipment Group LLC
[608]
24
4-7/8 TREATED/
UNTREATED WA
[125]
2-5/8 ELECTRIC SERVICE
[66]
1-1/2 DRAIN
[31]
20
[508]
LEVELING
FEET
2
[50]
FEET
2-1/2
[64]
4
[102]
DELIME PORT
33
[842]
23-3/8
[594]
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F47126 (01/15)
NOTE: In line w ith its policy to co ntinua lly imp rove its pr oduct s, Vulca n reser ves the right to c hange materia ls and sp ecic ation s withou t notice.