Vulcan C24EA10-DLX User Manual

Model C24EA6
Item # C.S.I. Section 11420
STEAM
C24EA FLOOR SERIES
ELECTRIC CONVECTION STEAMER
ON CABINET BASE
C24EA6-BSC 6 pan capacity basic controls C24EA6-DLX 6 pan capacity professional controls C24EA10-BSC 10 pan capacity basic controls C2 4 E A10-DL X 10 pan capacity professional controls
STANDARD FEATURES
■ Stainless steel exterior.
■ Two stainless steel cooking compartments with coved interior corners.
■ Stainless steel steam generator with staged water ll, and Smart Drain System (timed drain) with PowerFlush.
■ Separate 60 minute timer with constant steam feature for each compartment.
■ Heavy duty doors and door latch mechanisms with gasket guard.
■ Stainless steel water resistant cabinet base with enclosed bottom.
■ 6" adjustable stainless steel legs with anged feet.
■ Shipped for 208/60-50/3 electrical service. Can be eld converted to 208/60-50/1 and 240/60-50/3 and 240/60-50/1.
■ Split water line connection. Treated and untreated water connections. 11⁄2" NPT drain connection.
■ One year limited parts and labor warranty.
SPECIFICATIONS
Two compartment electric convection steamer on cabinet base. Stainless steel exterior. Two stainless steel cooking com­part ments with coved interior corners. Stainless steel steam generator with staged water ll and Smart Drain System (timed drain) with PowerFlush. Separate 60 minute timer with constant steam feature for each compartment. Heavy duty doors and door latch mechanisms. Stainless steel water resistant cabinet base with stainless steel enclosed bottom. 6" adjustable stainless steel legs with anged feet. Shipped for 208/60-50/3 electrical service. Can be eld converted to 208/60-50/1 and 240/60-50/3 and 240/60-50/1. Split water line connection. Treated and untreated water connections. 11⁄2" NPT drain connection.
Exterior Dimensions:
6 pan: 24"w x 35.4"d x 58.5"h on 6" legs. 10 pan: 24"w x 35.4"d x 67.9"h on 6" legs.
UL listed. Classied by UL to NSF Standard #4.
OPTIONS
Professional Control Package (Deluxe) includes:
- Superheated Steam System
480 volt, 50/60 Hz, 3 phase
Steamer Security Package, includes controls protected by lockable cover, perforated ue cover, security fasteners & tack-welds.
Second year extended limited parts and labor warranty contract.
ACCESSORIES (Packaged & Sold Separately)
Stainless steel pan cover. Qty.____.
Removable sliding shelf. Qty.____.
Water treatment system.
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F35471 (01/15)
STEAM
C24EA FLOOR SERIES
ELECTRIC CONVECTION STEAMER
ON CABINET BASE
SERVICE CONNECTIONS:
ELECTRICAL CONNECTION: Single point supply 11⁄8" (29 mm)
dia. (3⁄4" conduit).
DRAIN: Condenser box, compartment and generator, 11⁄2" NPT.
(Provide an open air gap type drain within 12" of condenser box and for best results at a distance so steam vapors will not enter the steamer from underneath the control area. Do not connect solidly to any drain connection.)
GENERATOR WATER SUPPLY: 3⁄4" (19 mm) male NSHT
to generator, cold water ow rate .5 gpm @ minimum 20 to maximum 60 psi. (138-414 kPa) treated water.
CONDENSING WATER SUPPLY: 3⁄4" (19 mm) male NSHT
to condenser, cold water ow rate .5 gpm @ minimum 20 to maximum 60 psi. (138-414 kPa) untreated water.
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable for steam generation. Your water supply must be within these general guidelines:
SUPPLY PRESSURE 20 - 60 psig HARDNESS* less than 3 grains SILICA less than 13 ppm TOTAL CHLORIDE less than 4.0 ppm pH RANGE 7-8 UN-DISSOLVED SOLIDS less than 5 microns * 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. Water supplies vary from state to state and from locations within a state. Therefore it is necessary that the local water treatment specialist be consulted before the installation of any steam generating equipment.
NOTE:
• Dimensions which locate the above connections have a tolerance of + or -3" (+ or -75 mm). Normal dimensions are in inches. Dimensions in ( ) are in millimeters.
• Installation of backow preventers, vacuum breakers and other specic code requirements is the responsibility of the owner and installer. It is the responsibility of the owner and installer to comply with local codes.
• Do not use plastic drains.
• This appliance is manufactured for commercial installation only and is not intended for home use.
COMPARTMENT PAN CAPACITY
MODEL 1" 21⁄2" 4" 6"
C24EA6 6 3 2 1
C24EA10 10 5 3 2
24.0
35.5
(901)
(102)
CONDENSATE
BOX VENT
MODEL PH
C24EA6-BSC
C24EA10-BSC
(609)
4.0
8.0 (203)
2.0 (51)
23.9
(607)
DRAIN
2.0 (51)
2.0 (51)
2.1
(53)
DRAIN
NO OPEN DRAIN
CONDENSATE
BOX VENT
BASIC CONTROL PACKAGE
208 V 240 V 480 V
KW AMP KW AMP KW AMP
1 16.0 77 17.8 74 N/A N/A 3 16.0 44 17.8 51 16.0 19 1 24.0 115 24.9 104 N/A N/A 3 24.0 67 24.9 65 24.0 29
29.8
(758)
6 PAN 58.7 (1490) 10 PAN 71.5 (1823)
6 PAN 55.0 (1397)
10 PAN 67.9
(1730)
28.0
(712)
6.0
(152)
C24EA6-DLX
C2 4 E A10 -DL X
ELECTRICAL
3.2 (82)
12.0
(305)
24.0
(610)
PROFESSIONAL CONTROL PACKAGE
MODEL PH
1 16.9 81 19.0 79 N/A N/A 3 16.9 48 19.0 53 17.2 21 1 25.2 121 26.5 110 N/A N/A 3 25.2 72 26.5 67 25.6 32
16.7
(424)
UNTREATED
WATER
(230)
4.5 (115)
10.5
9.0
(267)
TREATED
WATER
208 V 240 V 480 V
KW AMP KW AMP KW AMP
NOTE: 3ø is an unbalanced load, and amps listed is the max on any leg. Refer to the Installation and Operation Manual for further details.
a divisi on of IT W Food Equ ipment Group LLC
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F35471 (01/15)
NOTE: In line w ith its policy to co ntinua lly imp rove its pr oduct s, Vulca n reser ves the right to c hange materia ls and sp ecic ation s withou t notice.