For additional information on Vulcan or to locate an authorized parts and
service provider in your area, visit our website at www.vulcanequipment.com
INSTALLATION & OPERATION MANUAL
GAS CHARBROILERS
IMPORTANT FOR YOUR SAFETY
Improper installation,
adjustment, alteration, service or maintenance
can cause property damage, injury, or death.
Read the installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO
INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD
START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS
MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN
THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE
OBTAINED FROM THE LOCAL GAS SUPPLIER.
IMPORTANT
IN THE EVENT A GAS ODOR IS DETECTED, SHUT
DOWN UNITS AT MAIN SHUTOFF VALVE AND
CONTACT THE LOCAL GAS COMPANY OR GAS
SUPPLIER FOR SERVICE.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.
IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE.
- 2 -
INSTALLATION, OPERATION AND CARE OF
Model
Number of Burners
Natural Gas BTU/hr
Input Rating
LP Gas BTU/hr
Input Rating
VACB25 / ACB25
4
68,000
64,000
VACB36 / ACB36
6
102,000
96,000
VACB48 / ACB48
8
136,000
128,000
VACB60 / ACB60
11
187,000
176,000
VACB72 / ACB72
13
221,000
208,000
GAS COUNTERTOP CHARBROILERS
GENERAL
Vulcan/Wolf Gas Countertop Charbroilers are designed for commercial use only and
feature fast, efficient gas heat. Each burner is controlled by an adjustable gas valve.
Cast radiants are located directly above each burner to maintain uniform temperature.
Radiants are easily removed for cleaning when cool.
Heavy-duty cast iron top grates are reversible to allow all or part of the cooking grid
surface to be level or sloped. A crumb tray is provided to collect fat run-off and debris;
it opens to the front for inspection or cleaning.
INSTALLATION
UNPACKING
This charbroiler was inspected before leaving the factory. The carrier assumes full responsibility for the
safe delivery upon acceptance of the shipment. Check for possible shipping damage immediately after
receipt.
If the charbroiler is found to be damaged, complete the following steps:
1. Carrier must be notified within 5 business days of receipt.
2. Carrier’s local terminal must be notified immediately upon discovery (note time, date, and
who was spoken to), and follow up and confirm with written or electronic communication.
3. All original packing materials must be kept for inspection purposes.
4. The charbroiler cannot have been moved, installed, or modified.
5. Notify Vulcan Customer Service immediately at 800-814-2028.
Carefully unpack your charbroiler and make sure that no parts are discarded with
packaging material. A pressure regulator designed to operate with the broiler has been
supplied and must be installed before the charbroiler is placed into service (Refer to GAS
PRESSURE REGULATOR INSTALLATION in this manual).
- 3 -
Before installing, verify that the type of gas (natural or propane) and the clearance
dimensions agree with the specifications on the rating plate which is located on the lower
front corner on the right side.
LOCATION
The installation location must be kept free and clear of combustibles. Do not obstruct the
flow of combustion and ventilation air. DO NOT install the charbroiler adjacent to fryers
unless following the provisions detailed by local codes and/or the applicable sections of
ANSI-Z223.1/NFPA #54 (latest edition) and NFPA #96 (latest edition) in the United States
of America or CAN/CSA 149.1 (latest edition) and CAN/CSA149.2 (latest edition) in
Canada.
Sufficient air should be allowed to enter the room to compensate for the amount of air
removed by any ventilating system and for combustion of the gas burners. Do not
obstruct the air flow into and around the appliance. Do not obstruct the flow of flue gases
through and above the broiler's top grate. Position the broiler in its final location. Check
that there are sufficient clearances to service the broiler and to make the required gas
supply connection(s). Provide 24" clearance at the front for cleaning, maintenance,
service and proper operation.
This broiler is for use in non-combustible locations only. Installation in combustible
locations is prohibited unless following the provisions detailed by local codes and/or the
applicable sections of ANSI-Z223.1/NFPA #54 (latest edition) and NFPA #96 (latest
edition) in the United States of America or CAN/CSA 149.1 (latest edition) and
CAN/CSA149.2 (latest edition) in Canada and approved by the authority having
jurisdiction.
Minimum clearances to non-combustible walls are 3" to the rear and 3" to the sides.
INSTALLATION CODES AND STANDARDS
The Charbroiler must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but
not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained
from The American Gas Association Accredited Standards Committee Z223, @ 400
N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA,
1 Batterymarch Park Quincy, MA 02169-7471
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or exhaust system equipped with
a damper or with a power means of exhaust shall comply with 248 CMR.
3. NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Local codes.
2. CAN/CSA-B149.1 Natural Gas Installation (latest edition)
3. CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the
Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3
- 4 -
KEY COMPONENTS
Crumb Tray
Fig. 1
Burner
Radiant
Grate
Super Charger
Burner Divider
Deflector Tray
Hook
Slot
Fig. 2
Enlarged View of Hook
Engaged In Slot
Supercharger Guide
Fig. 3
The charbroiler
and its parts are hot. Use care
when operating, cleaning or
servicing the charbroiler.
Grate – The grates can be utilized
flat or sloped for operational
flexibility.
Deflector Tray – The deflector tray
is the removable pan with holes in
it. The deflector tray deflects heat
back toward the cooking surface
while allowing debris to pass
through the holes and into the
crumb tray below. The deflector
tray should always be in place
above the crumb tray when
operating.
Never cover the
deflector tray holes with foil or
allow the deflector tray holes to
become blocked with debris. This
will cause a buildup of heat that
can potentially damage and warp
components of the charbroiler.
Crumb tray – The crumb tray is the
removable pan without holes in it.
The crumb tray catches any debris
that passes thru the deflector tray
and should always be installed
beneath the deflector tray. (Fig. 1).
Supercharger Burner Divider These act as dividers between
cooking zones to offer flexibility in
cooking and help direct heat
upwards to provide for a even
heating pattern. You may remove
some or all of the supercharger
burner dividers at your discretion if
you find your production method
works better without them. The
super charger burner dividers are
installed by inserting the hooks
thru corresponding slots at the
front (Fig. 2) and the back rests in
the super charger guide to the
rear. (Fig. 3).
- 5 -
Radiant – The charbroiler must
never be operated without the
radiants in place. They protect the
burner from food drippings and
heat up to provide an even heating
pattern. The radiants are installed
by inserting the tab thru the
corresponding slot in the heat
shield to the front (Fig. 4-A) and
the back of the radiants set on the
radiant rest to the rear (Fig. 5-A).
Burner – The burner shutter
should engage the orifice to the
front (Fig. 6) and rest in the
burner slot to the rear of the unit.
Proper burner shutter adjustment
is important for optimal charbroiler
performance. The burner shutters
should only be adjusted with all
radiants in place. The shutter will
typically be about 50% open for
natural gas and 80 to 100% open
for LP. A properly adjusted burner
should exhibit solid blue flames
that are touching the burner. All
traces of yellow should be
adjusted out of the burner flame
for natural gas and only a slight
yellow tipping should be observed
on LP gas. Large, yellow tipped
flames typically indicate not
enough air and the burner shutters
should be opened slightly.
Floating flames (not touching the
burner) typically indicate too much
air and the shutter should be
closed slightly.
Fig. 4
Fig. 5
Fig. 6
Radiant Tab
Heat Shield Slot
Radiant Rest
Burner Shutter
Orifice
Burner Valve
A
B
A
B
- 6 -
LEVELING
It is important that the charbroiler is level front to back and left to right. Areas of uneven
heat distribution will occur on an unlevel unit. The charbroiler is equipped with adjustable
legs. Turn the feet at the bottom of the legs to adjust to level. The unit should be
rechecked for level anytime it has been moved.
VENTILATION HOOD
The broiler must be installed under a suitable ventilation hood. For safe operation and
proper ventilation, keep the space between the charbroiler and vent hood free from any
obstructions.
GAS CONNECTION
The data plate on the lower right side of the charbroiler indicates the type of gas your unit
is equipped to burn. DO NOT connect to any other gas type.
All gas supply connections and any joint compound must be
resistant to the action of propane gases.
Purge the supply line to clean out any dust, dirt, or any foreign matter before connecting
the line to the unit.
Codes require that a gas shut-off valve be installed in the gas line ahead of the
charbroiler. The gas supply line must be at least the equivalent of ¾” iron pipe.
60” a n d 7 2 ” m o del s h a v e a g as inlet at each end of the unit. The unit will arrive from the
factory with a metal cap on one end and a plastic dust cover on the other. You may move
the metal cap to the other end and use which ever connection point is most convenient to
the available supply outlet. The plastic dust cover must be replaced with a metal pipe cap
if you do not use that location as the gas inlet. Do not connect both of the available
charbroiler gas inlets to the gas supply.
A pressure regulator is supplied and must be installed outside of the broiler when making
the gas supply connection. Standard orifices are set for 5"WC (Water Column) for
Natural Gas — 10"WC (Water Column) for Propane. Use the 1/
” pipe tap on the bur n er
8
manifold for checking pressure. Make sure the gas piping is clean and free of
obstructions, dirt, and piping compound.
An adequate gas supply is necessary. Undersized or low pressure lines will restrict the
volume of gas required for satisfactory performance. A minimum supply pressure of 7"
W.C. for natural gas and 11" W.C. for propane gas is recommended. With all units
operating simultaneously, the manifold pressure on all units should not show any
appreciable drop.
When testing the gas supply piping system, if test pressures exceed ½ psig (3.45 kPa),
the charbroiler and its individual shutoff valve must be disconnected from the gas supply
piping system. When test pressures are ½ psig (3.45 kPa) or less, the charbroiler must
- 7 -
be isolated from the gas supply piping system by closing its individual manual shut-off
Fig. 7
Fig. 8
Connect Gas Line
Strain Relief Here
Fig. 9
Charbroilers mounted on stands with casters
must use a flexible connector (not supplied) that
complies with the Standard for Connectors for
Mo va b le Gas Appl ia n c e s , ANSI Z21.69 • CSA
6.16 and a quick-disconnect device that complies
with the Standard for Quick-Disconnect Devices
for use With Gas Fuel, ANSI-Z21.41 • CSA 6. 9.
In addition, adequate means must be provided to
limit movement of the broiler without depending
on the connector and the quick-disconnect device
or its associated piping to limit broiler movement.
Attach the restraining device at the rear of the
charbroiler. If disconnection of the restraint is
necessary, turn off the gas supply before
disconnection. Reconnect the restraint prior to
turning the gas supply on and return the
charbroiler to its installation position.
valve during any pressure testing of the system.
Prior to lighting, check all joints in the gas supply line for leaks.
Use soap and water solution. Do not use an open flame.
GAS PRESSURE REGULATOR INSTALLATION
Gas regulator pressure is preset at 5” W ater Column (W . C . ) for natural g as, and 10” W .C.
for propane gas. Minor adjustments may be required based on site specific gas pressure.
Install the regulator as close to the broiler on the gas supply line as possible. Make sure
that the arrow on the underside of the regulator is oriented in the direction of gas flow to
the broiler (Fig. 7) and the regulator is positioned with the vent plug and adjustment
screw upright (Fig. 8).
The supply pressure (upstream of the regulator) should be 7-9 ” W .C. for natural gas and
11-12” W .C. for propane gas. At no time should the charbroiler be connected to supply
pressure greater than ½ psig (3.45 kPa) or 14” W. C.
CASTER EQUIPPED CHARBROILERS
Charbroilers mounted on stands with casters must use aflexible connector (not supplied) that complies with the Standard for Connectors for Movable Gas Appliances, ANSIZ21.69 • CSA 6.16 and aquick-disconnect devicethat complies with the Standard for Quick-Disconnect Devices for use With Gas Fuel, ANSI-Z21.41• CSA 6.9. In addition, adequate means must be provided to limitmovement of the broiler without depending on theconnectorand the quick-disconnect device or itsassociated piping to limit broiler movement. Attachtherestraining device at the rear of the charbroiler.If disconnection of the restraint is necessary, turnoff the gas supply beforedisconnection. Reconnectthe restraintprior to turning the gas supply on and return the charbroilerto its installation position.
- 8 -
The charbroiler and its parts are hot. Use care when operating,
Pilot Control Valves – The pilot
control valves are located between
the burner control knobs and
accessed thru slots in the front panel
(Fig. 10). There is one pilot and
corresponding adjustment screw for
every burner.
Using a flathead screwdriver, turn the
slotted, hex-head pilot adjustment
screw clockwise to decrease the
flame and counter clockwise to
increase the flame. Standing pilots
should be adjusted to provide a slight
yellow tip on the flame.
Burner Control Valves – There is one
valve for each burner. To initially
light the burners, the knobs should
be turne d to t h e “MAX ” setting then
adjusted to the desire setting as
needed.
The burners will be off when the
control knob is turned all the way to
the right and pointin g to “OF F ” . T h e
burners will be at maximum setting
when turned all the way to the left
and poi nting to “ MAX”. A m edium
burner setting can be achieved by
adjusting the knob approximately half
way be t w een th e “O F F ” and “MAX”
marks. See Fig. 11.
The charbroiler is a free vented
appliance. All products of
combustion and the heat generated
by the burners passes through the
grates. When food products are
placed on the grates, this blocks the
venting and causes a temperature
build-up.
OFF MEDIUM MAXIMUM
Pilot Sight Holes
Pilot Control Valve
Fig. 10
Fig. 11
Burner Control Valve
cleaning or servicing the charbroiler.
CONTROLS
OPERATION
TO COMPLETELY SHUTDOWN THE BURNERS AND PILOT LIGHTS
For complete shutdown: Turn the main gas supply valve OFF. Make sure all individual
burner valves are OFF.
PREHEATING THE CHARBROILER
Allow the charbroiler to preheat for 30 minutes. Rub grates with cooking oil before using.
- 9 -
Fig.10
LIGHTING THE GAS PILOT
1. Turn the main gas shut-off valve
and the individual burner gas
valves OFF. Wait 5 minutes.
2. Turn the main gas shut-off valve
ON.
3. Light each pilot using an outside
ignition source. Pass the ignition
source through the pilot access
hole in the front panel and ignite
the pilot (Fig. 12). The end of the
ignition source will need to be at
le a s t 7” l o n g so it can extend pass
the front panel to reach the pilot
inside.
4. While viewing through the pilot
access hole, adjust the
corresponding pilot valve screw
until the pilot has a slight yellow
tip
5. Repeat steps 3-4 until all pilots
are lit.
6. To light the burners, turn the
individual burners valves ON (MAX
setting) after all pilots are lit. (Fig.
13). If the burners fail to light, turn
all burner valves and the main gas
shut-off valve to the OFF position
and contact an authorized service
agency.
CLEANING
The charbroiler
and its parts are hot. Use care
when operating, cleaning or
servicing the charbroiler.
Scrape top grates during broiling
with a wire brush to keep the
grates clean. Do not allow debris
to accumulate on the grates. (Fig.
14)
Pilot
Fig. 12
Pilot Valve
Fig. 13
Fig. 14
Pilot Access Hole
- 10 -
Top grates may be immersed in
strong commercial cleaning
compound overnight. In the
morning, rinse with hot water to
remove any residues of cleaning
compound. Thoroughly dry and
apply cooking oil to prevent
rusting.
Stainless steel surfaces may be
cleaned using damp cloth with
mild detergent and water solution.
Daily, when cool, remove top
grates and radiants to clean
places where fat, grease, or food
can accumulate. (Fig. 15)
Deflector trays and crumb trays
should be emptied and cleaned
regularly when cool. Ensure that
the rear hooks of the deflector tray
are over the back edge of the
crumb tray as shown in Fig. 16
when reassembled.
Deflector Tray
Crumb Tray
Fig. 15
Fig. 16
Deflector Tray Hook
Never cover the surface of the charbroiler with pans or other objects in attempt
to “burn off ” or clean debris from unit. T h i s will cau se a buildup of heat that can
potentially damage and warp components of the charbroiler.
Never cover the deflector tray holes with foil or allow the deflector tray holes to
become blocked with debris. This will cause a buildup of heat that can potentially
damage and warp components of the charbroiler.