Table of
1. Product Overview ......................................................................................................................... 3
2. Main Functions & Features .............................................................................................................. 3
3. For Your Safety ............................................................................................................................ 4
4. VT-G992E Characteristics ............................................................................................................... 4
5. Getting Started ............................................................................................................................. 5
5.1 Standard Package List ........................................................................................................ 5
5.2 View ................................................................................................................................ 5
5.3 Functional Parts ................................................................................................................ 6
5.4 Connecting and Installation ................................................................................................ 8
6. Operation Instructions: the factory password is: 0000 ............................................................................ 12
6.1 Keyboard setting: ............................................................................................................ 12
6.1.1 Password: ................................................................................................................... 12
6.1.2 Siren alarm sound enable/disable: .................................................................................. 12
6.1.3 Set up alarm calling telephone numbers: ......................................................................... 12
6.1.4 Delete alarm calling telephone numbers: ......................................................................... 12
6.1.5 Siren alarm sound time out: ......................................................................................... 12
6.1.6 Alarming delay: ........................................................................................................... 12
6.1.7 ARMING delay: ............................................................................................................ 12
6.1.8 Remote telephone ringing times: ................................................................................... 12
6.1.9 Siren sound feedback when using the remote control:....................................................... 13
6.1.10 Voice reminder function on/off and buzzer sound on/off: ................................................ 13
6.1.11 Alarm message recording: ........................................................................................... 13
6.1.12 Register and Delete remote controller/sensors: .............................................................. 13
6.1.13 Setting wired zones L1/L2: .......................................................................................... 13
6.1.14 Zone mode settings: ................................................................................................... 14
6.1.15 Alarm event history: ................................................................................................... 14
6.1.16 Telephone line tampering detection: .............................................................................. 14
6.1.17 Remote controller enable/disable: ................................................................................. 14
6.1.18 Remote control OUT power output: ............................................................................... 14
6.1.19 Setting up the system time and timing ARM/DISARM: ..................................................... 14
6.2 GSM messaging prompting: ............................................................................................. 15
6.2.1 Editing SMS prompting messages; ( 9 groups .................................................................. 15
6.2.2 Set the types of 6 groups alarming telephone number and power failure ............................. 15
6.2.3 Set the brightness adjustment of digital display ............................................................... 15
6.2.4 SMS commands: where 0000 is the password .................................................................. 15
7. Remote Controller (Key fob) Description ............................................................................................ 16
7.1. Set up Arm .................................................................................................................... 16
7.2 Set up Disarm ................................................................................................................. 16
7.3. Emergency Alarm ........................................................................................................... 16
7.4. Intelligent Arm ............................................................................................................... 16
8. Alarm Panel LED Screen Indicator Status Description: ........................................................................... 16
9. Remote Control the system: ........................................................................................................... 17
10. Handing Incoming Alarm Phone Calls ............................................................................................. 17
11. Reset Factory Settings ................................................................................................................ 17
12. Copyright and Disclaimer ........................................................................................................ 17
Contents
Page: 2 / 17
1. Product Overview
VT-G992E is a GSM and PSTN intelligent home alarm system. This LED display alarm system is equipped with dual network GSM & PSTN technologies and suitable for both home and commercial use. It uses advanced GSM technology, GSM Wireless mobile and traditional PSTN landline networks with intelligent alarm system. It has highly integrated digital voice, SMS, self-learning wireless communication code, and text­messaging technologies. The alarm provides automatic voice or SMS messaging as notification for incidents. It is a choice of stability, reliability, security, and user-friendliness. Features are very practical, cost-effective, and easy to use. This LED display alarm can integrate with many alarm accessories including door sensors, smoke detectors, gas detectors, emergency buttons and other accessories to build a powerful security setup. It has been widely used in homes, factories, schools, shops, convenience stores, financial and banking workplaces, community centres and residential areas to provide protection to valuable assets.
2. Main Functions & Features
VT-G992E has the following main functions and features:
99 Wireless Zones and 2 wired zones with LED display DC12V output(connect to wired sensors) Support both GSM & PSTN telephone English voice operation instruction LED indicator Arm/Disarm/Stay arm/Alarm/Setting/Signal Password protection function 5 groups of call phone number and SMS number, 1 group of emergency phone number and SMS
number
Programmable alarm delay: 0-99 seconds Programmable alarm arming delay: 0-99 seconds Programmable Siren sounding: 0-30 minutes Zone name self-editing function Programmable ring times Timing arm and Timing disarm Stay intelligent arm Multi-Zones Triggered Mode (2 or more than 2 zones) Repeat triggered alarm function (sensor alarm after triggered twice) Doorbell Anti-decoding protection function Telephone line cutting detection External power on and off SMS notification Remote control via SMS and Phone Remote control output for door open or light,… Remote control to turn on and off Siren Remote Monitoring/Arm/Disarm/Play records Two way talking (External)
Page: 3 / 17
3. For Your Safety
Proper Connection
Qualified Accessories
Water Resistance
Confiden
tial Phone Number
Items
Specification
Read these simple guidelines. Not following them may be dangerous or illegal.
When connecting with other device, read carefully its manual so as to carry out correct installation. Do not connect it to other incompatible devices. Use only original parts and peripheral equipments to avoid damage to VT-G992E. VT-G992E is not water resistant. Keep it dry. Install it inside the house For safety reason, do not tell other people the mobile phone number of your VT-G992E without taking precautions of security settings.
4. VT-G992E Characteristics
Power Supply DC12V / 1A Backup Battery Ni-Hi AAA*6 DC7.4V Frequency GSM 900/1800/1900Mhz Standby current
Alarm current Wireless frequency 433MHz
Support wireless sensors EV1527/300K 2262/1.5-4.7M Wireless distance 100m open Record voice message 10s LED screen display time/Arm/Disarm/Stay arm/Alarm/Setting Operating temperature -10° to 50° C Humidity 5% to 95% Non-condensing Dimension 33*25*7.5cm Weight 1.2KG
55 mA
450 mA
Page: 4 / 17
5. Getting Started
This section will describe how to set up your VT-G992E.
5.1 Standard Package List
VT-G992E is supplied in a box which includes:
5.2 View
Front View Side View Back View
Page: 5 / 17
5.3 Functional Parts
LED screen display
LED indicator
Microphone
Function keyboard
Speaker
Digital Keyboard
HomeSaf
e
F4 GSM is unavailable F5 Turn on GSM
F6 Access GSM network
88:88 Minutes : Seconds
POWER Power LED light, power supply working normal ALARM Alarm LED light, alarm system alarm TELEPHONE Telephone LED light, telephone line work normal
Mobile LED flashes every 3 seconds, GSM network working
MOBILE
ARMING ARMING LED light, the alarm system into arm status INTELLIGENT INTELLIGENT LED light, the alarm system into intelligent
DISARMING DISARMING LED light, the alarm system into disarm
ALARM ALARM LED light, the alarm system into alarm status
normal; If the LED still light, access GSM network fail Personal message record and remote monitoring
status
status
English voice operation instruction Setting alarm system function
Page: 6 / 17