Use, duplication, or disclosure by the Government is subject to restrictions
set forth in subparagraph (c) (1) (iii) of the Rights in Technical Data and
Computer Software clause at DFARS 252.227-7013.
The information contained in this document is subject to change without
notice. VTEL assumes no responsibility for technical or editorial errors or
omissions that may appear in this manual or for the use of this material;
nor does VTEL make any commitment to update the information contained
in this document.
VTEL CorporationVTEL Europe Ltd.
108 Wild Basin RoadApex Plaza
Austin, Texas 78746 USAReading, Berkshire RG11AX UK
ii
Notices
Canadia n De partment of Com munications N o tic es
Class A Limits
The digital apparatus does not exceed the Class A lim its for radio noise emis sions from
digital apparatus as set out in the Radio Interference Regu lations of t h e Canadian
Department of Communicat ions.
Load Number
The Load Number (LN) assigned to each terminal device denotes the percentage of the
total load to be connected to a telep hone loop used by the device to prevent overloading.
The termination of a l oop m ay consist of any combination of devic es subject only to the
requir em ent that the sum of the load numbers of all devices does not exceed 100.
Attac hment Limitation
The Canadi an D epartment of Com m unications label identifies ce rtified equipment.
This cer tification m eans that the equipment meets certai n telecommunications network
protective, operational, and safety requirements. The Department does not guarantee
the equipment will operate to the user’s satisfaction.
Before ins tall i ng this equ ip ment , users shoul d ensu re that it is permissi bl e to be con necte d
to the facilities of the local telecommunications company. An acceptable method of
connect ion must be used to install the equipment. The customer should be aware that
compliance with the above conditions may not prevent degradation of service in some
situations.
Repairs to certifi ed equipment should be made by an authorized Canadian maint enance
facility designated by the supplier. Any repairs or alterations made by the user to this
equipment, or equi pment malfunctions, m a y give the telecommunication s company cause
to reque st that the user disconnect the equipment.
For thei r ow n protecti on, users shoul d ensure that the electrical ground connections
of the power utility, telephone lines, and i nternal metallic water pipe system, if prese n t,
are conne cted together. This precaution may be par ticularl y im portant in rural areas.
Caution:
Users sh ould not atte mpt to make su ch co n nections th emselve s,
but shou ld cont ac t t he appr opr i ate el ec tric ins pe ction aut hor ity o r
electrician as appropriate.
iii
FCC Notice
This equi pmen t co mpli es with Par t 68 of t he FCC ru le s. On the back o f this equ ipme nt is a
label that contains, among other information, the FCC registration number and ringer
equival ence number (R EN ) for this equipment. If requested, this in formation must be
provided to the telephone company.
The REN is used t o determine the quantity of devices which may be connected to the
telephone li ne. Exce ss ive RENs on t he tel eph one line m ay resu lt in the devi ce s not ri ngi ng
in response to an incoming call. I n most, but not al l areas, the sum of the RENs should not
exceed f ive (5. 0) . To be cer t ain of the nu mber of d evi ces th at may be c onne cted t o th e li ne,
as determined by the total RENs, contact the telephone company to determine the
maximum REN for the calling area.
This equi pm ent uses the following USO C jacks: RJ11C
An FCC-compliant telephone cord and modular plug is provided with this equipment.
This equi pm ent is designed to be connected to the telephone network or premises wiring
using a compatible modular jack which is Part 68-compliant.
This equi pm ent cannot be used on teleph one company-p rovided coin service. Connection
to Party Line Service is subject to state tariffs.
If this equipment causes harm to the telephone network, the telephone com pany will
notify y ou in advance that temporary discontinuance of the service may be require d. If
advance notice isn’t practical, the telephone company will notify the customer as soon as
possib le. Also, you will be advise d of your right t o file a complaint with the FCC if you
believe it is nece ssary.
iv
The tele phone company may make changes in its facilities, equ ipment, operations, or
procedu res that could affect the operation of th e equipment. If this happens, the telephone
company wi ll provi de adv anc e noti ce in ord er fo r yo u t o mak e the n ece ss ary m odif ic ation s
in order to ma in ta in uninter ru pted servi ce .
If trouble is experienced with this equipment, contact VTEL Technical Assistance Centerat 800-856-VTEL, 512 314 2750, or 610-239-5555 for repair an d (or) warra nt y
information. If the trouble is causing harm to the telephone network, the tel ephone
company may request that you remove the equipment fr om the networ k
until the problem is resolved.
Any repairs to this equipment must be made by VTEL, or a VTEL-certified Technician
or repair facility.
It is recommended that the cu stomer install an AC surge arrestor i n the AC outlet to which
this dev ice is connected. This is to avoid equipm ent damage ca used by local lightening
strikes and other ele ctrical surges.
Austel Notice: For Use in Australia
This equi pment can be connected to a telecommunications service only by an
Austel-permitted terminal adapter.
v
Safety Notices and Warnings*
Consignes de sécurité et mises en
garde
†
Sicherheitshinweise und Warnungen
Avisos y advertencias de seguridad
Selection and integration of accessory equipment
*
The interconnection and/or installation of any accessory equipment must
be performed by a qualified biomedical technician familiar with the
requirements and hazards associated with the use of electronic equipment
in a medical environment.
†
Sélection et intégration des équipements accessoires
L’interconnexion et/ou l’installation de tous les équipements accessoire s
ne doivent être effectuées que par un technicien biomédical connaissant
les obligations et dangers présentés par l’utilisation d’équipements
électron iqu es en milieu méd ic al.
Auswahl und Integration von Zusatzgeräten
•
Der Anschluß und/oder die Installation von Zusatzgeräten darf nur von
einem qualifizierten, biomedizinischen Techniker durchgeführt werden,
der über die Anforderungen und Gefahren, die beim Einsatz von
elektronischen Geräten in einer medizinischen Umgeb ung auf treten
könnten, gut informiert ist.
•
‡
‡
La selección e integración del equipo accesorio
Un técnico biomédico competente familiarizado con los requisitos y
riesgos relacionados con el uso del equipo electrónico en un ambiente
vi
médico, debe hacer la interconexión e/o instalación de cualquier equipo
*
accesorio.
Equipment Application
*
The HS 2000 is a video conferencing system intended for use in a medical
patient care environment.
The HS 2000 has been designed for use in a patient care area, within
patient proximity. The product is not intended for electrical connection to a
patient. The product is intended for use by health care providers to
facilitate better communication between other health care providers, and
patients. The product is not intended for remote diagnosis of patients, but
rather for consultative applications in which a local expert is seeking the
opinion of, to educate or converse with a remote party. The product is in
no way intended to provide treatment of a patient or to modify the patient
environment. The HS 2000 is not intended to measure or provide
quantitative data pertaining to patient care.
It should be realized that all video, audio, and other data transmitted
through the HS 2000 is digitally encoded for transmission via the
communication medium, and decoded at the remote location. The image
quality is dependent on a number of factors, including the type of telephony
used.
The product uses electronic circuitry that emits electromagnetic radiation.
Compliance testing to European standard EN60601-1-2 dem onst rates
that the level of these emissions is at or below acceptable limits.
†
Emploi de l’équipement
Le HS 2000 est un système de vidéo-conférence, destiné à une utilisation
en milieu médical.
Le HS 2000 a été conçu pour être utilisé sur les lieux des soins, à proximité
du patient. Ce produit n’est pas destiné à connecter électriquement le
patient. Il a été conçu à l’intention de certains responsables médicaux, afin
de permettre une meilleure communication entre les patients et d’autres
responsables médicaux. Ce produit n’a pas été conçu pour permettre un
diagnostic à distance des patients. Il est plutôt destiné à des fins
consultatives permettant à un expert local d’obtenir à distance, l’opinion
vii
d’une autre partie, de lui fournir des informations et de discuter du cas. Le
produit n’a en aucun cas, été conçu comme un véhicule de traitement des
patients ou de modification de leurs conditions de traitement. Le HS 2000
n’est pas destiné à l’évaluation ou au rassemblement de données
quantitatives sur les soins reçus par le patient.
Il faut comprendre que l’ensemble des données vidéo, audio et autres,
transmises par l’intermédiaire du HS 2000, sont encodées numériquement
pour leur transmission, puis décodées à l’arrivée. La qualité de l’image
dépend donc d’un certain nombre de facteurs, comme le type de
téléphone utilisé.
Le produit renferme des circuits électroniques émettant des radiations
électromagnétiques. Les tests de conformité à la norme européenne
EN60601-1-2 révèlent un degré d’émission égal ou inférieur aux limites
acceptables.
Anwendung
•
HS 2000 ist ein Videokonferenz-System zur Verwendung in der
medizinischen Patientenpflege.
HS 2000 wurde für den Einsatz im Patientenpflegebereich, in der Nähe
des Patienten, entworfen. Dieses Produkt ist nicht für den elektrischen
Anschluß zu einem Patienten gedacht. Es wurde für Ärzte und Pfleger
entwickelt, um die Kommunikation zwischen anderen Ärzten und Pflegern
und Patienten zu vereinfachen. Dieses Produkt dient nicht zur
Ferndiagnose, sondern zu Beratungszwecken. Es ermöglicht dem
örtlichen Fachmann, von einem entfernten Fachmann des sen Mei nung
einzuholen, diesen zu unterrichten oder sich mit ihm zu unterhalten.
Dieses Produkt ist in keiner Weise für die Patientenbehandlung
vorgesehen, noch sollte es die Patientenumgebung modifizieren. HS 2000
ist nicht für die Messung oder Bereitstellung von quantitativen
Patientendaten vorgesehen.
Es ist zu beachten, daß Video, Audio und andere Daten, die von HS 2000
übertragen werden, zur Übertragung über die Kommunikationsmedien
digital verschlüsselt und am entfernten Standort wieder entschlüsselt
werden. Die Bildqualität ist von mehreren Faktoren abhängig,
einschließlich der verwendeten Fernsprechtechni k.
viii
Dieses Produkt verwendet eine elektronische Schalttechnik, die
‡
elektromagnetische Strahlung verursacht. Tests ergaben, daß der
Emissionsgrad den Grenzwerten der Europa-Norm EN60601-1-2
entspricht.
Aplicación del equipo
El HS 2000 es un sistema de videoconferencia destinado al uso en un
ambiente de asistencia médica de pacientes.
El sistema HS 2000 se diseñó para usarse en un área de cuidado de
pacientes, cerca de los pacientes. El producto no está destinado para
conectarse eléctricamente al paciente. El producto está destinado al uso
por parte de los proveedores de asisten cia a la salud para facilit ar una
mejor comunicación con otros proveedores de asistencia a la salud y con
los pacientes. El producto no está destinado para la diagnosis remota de
los pacientes, sino para aplicaciones consultivas en las que un experto
local busca la opinión de, o pretende educar o conversar con un individuo
en una ubicación remota. El producto no está destinado de ninguna
manera para el tratamiento de un paciente o para la modificación del
ambiente del paciente. El sistema HS 2000 no está destinado para medir
ni suministrar datos cuantitativos relacionados con el cuidado del
paciente.
Se debe comprender que todo el vídeo, audio, y demás datos transmitidos
a través del sistema HS 2000 se codifican de manera digital para su
transmisión a través del medio de comunicación, y luego se descodifican
en su lugar de destino. La calidad de imagen depende de una serie de
factores, así como el tipo de telefonía que se emplea.
*
El producto emplea un sistema de circuitos electrónicos que emite
radiación electromagnética. Las pruebas de conformidad con el estándar
europeo EN60601-1-2 demuestran que el nivel de estas emisiones es
igual o está por debajo de los límites aceptables.
Safety Considerations for Accessory Equipment:
The use of accessory equipment not complying with the equivalent safety
requirements of this equipment may lead to a reduced level of safety of the
resulting system.
ix
Consideration relating to the use of accessory equipment shall include:
†
Use of equipment in patient vicinity
Evidence that Safety Certification of the accessory equipment has
been performed
in accordance with the appropriate IEC 601 and IEC 601-1
Harmonized National Standards.
Considérations de sécurité soulevées par l’emploi
d’équipements accessoires :
L’utilisation d’équipements accessoires non conformes aux normes de
sécurité applicables à ce produit, risque de réduire le niveau de sécurité
de l’ensemble.
Préalablement à l’utilisation d’équipements accessoires, il faut considérer :
L’utilisation de l’équipement à proximité des patients
La preuve que l’homologation de l’équipement accessoire a été
effectuée en respect des normes nationales uniformisées IEC 601
et IEC 601-1.
Sicherheitsüberlegungen für Zusatzgeräte:
•
Wenn Zusatzgeräte verwendet werden, die nicht mit den
Sicherheitsanforderungen dieses Gerätes übereinstimmen, könnte
eventuell der Sicherheitsgrad des Endsystems beeinträchtigt werden.
Überlegungen bei der Verwendung von Zusatzgeräten:
Einsatz der Geräte in der Nähe des Patienten
Nachweis, daß die Sicherheitszertifizierung der Zusatzgeräte
gemäß der entsprechenden harmonisierten Norm IEC 601 oder
IEC 601-1 durchgeführt wurde.
x
‡
†
Consideraciones de seguridad para el equipo accesorio:
El uso de equipo accesorio que no se encuentra en conformidad con los
requisitos equivalentes de seguridad de este equipo puede reducir el nivel
de seguridad del sistema combinado.
Las consideraciones con respecto al uso del equipo accesorio deben
incluir:
El uso del equipo cerca de los pacientes
Pruebas que demuestren que se ha cumplido la certificación de
seguridad del equipo accesorio de acuerdo con los estándares
modificados nacionales IEC 601 y IEC 601-1 correspondientes.
Use of Internal AC Receptacle:
*
The VTEL HS 2000 uses power strips internally to provide power to
various subassemblies. Accessory equipmen t may be plugged into any
available AC receptacle provided that the overall current rating for the
system is not excee ded. The current draw for the speci fic HS 2000 system,
as well as the accessory equipment to be added, should be determined
separately. The total should not exceed the 3 Amp system rating.
L’utilisation de réceptacles CA internes
L’alimentation des divers sous-ensembles du VTEL HS 2000 se fait par
l’intermédiaire de câbles internes. Les équipements accessoires peuvent
être branchés sur n’importe quel réceptacle CA disponible, à condition de
ne pas dépasser la capacité globale du système. La demande en courant
spécifique au système HS 2000 en question, tout comme celle de
l’équipement accessoire utilisé, doivent être déterminées séparém ent.
Leur total ne doit pas dépasser les 3 ampères de capacité nominale du
système.
•
Verwendung der internen Wechselstromsteckdose:
VTEL HS 2000 verfügt über interne Mehrfachstecker, um verschiedene
Baugruppen mit Netzstrom zu versorgen. Zusatzgeräte können eventuell
an jede verfügbare Steckdose angeschlossen werden , solange der
Gesamtnennstrom nicht überschritten wird. Die Stromaufnahme für das
HS 2000-System sowie für die Zusatzgeräte, die hinzugefügt werden
xi
sollen, sind separat zu bestimmen. Der Gesamtwert darf den
†
Systemnennwert von 3 A nicht überschreiten.
‡
El uso de un receptáculo interno de CA:
El sistema VTEL HS 2000) emplea regletas de alimentación internas para
suministrar energía a varios subconjuntos. El equipo accesorio se puede
enchufar en cualquier receptáculo de CA disponible siempre que no se
exceda la corriente nominal global del sistema. El consumo de corriente
del sistema HS 2000 específico, así como el consumo del equipo
accesorio que se vaya a agregar, debe determinarse por separado. l total
no debe exceder la capacidad nominal del sistema de 3 amperios.
Safety Notices and Symbols
*
†
Remarques et symboles concernant la sécurité
Sicherheitshinweise und Zeichen
•
‡
Notas y símbolos de seguridad
*
•
‡
This symbol is intended to alert the user that liquids and other
items should not be placed on the system. This symbol also
indicates that caution should be used to assure that the system is
not located in proximity to overhead liquids.
Ce symbole est conçu pour avertir l’utilisateur que les liquides et
autres éléments ne doivent pas être présents sur le système. Ce
symbole indique également qu’il fa ut prendre la précaut ion de
s’assurer que le système ne se trouve pas juste au-dessus de
liquides.
Mit diesem Zeichen wird der Benutzer davor gewarnt,
Flüssigkeiten oder andere Gegenstände auf dem System zu
plazieren. Dieses Zeichen zeigt ebenfalls an, daß es von
äußerster Wichtigkeit ist sicherzustellen, daß keine Flüssigkeiten
über dem System gelagert oder geleitet werden.
Este símbolo indica al usuario que no deben colocarse líquidos
ni otros artículos sobre el sistema. Este símbolo también indica
que el usuario debe asegurarse de que el sistema no se coloque
en la proximidad de líquidos a mayor altura.
xii
*
†
•
‡
This symbol is intended to alert the user of the system that an
area of the system should not be leaned on or have heavy objects
placed on it
Ce symbole est conçu pour avertir l’utilisateur du système de
ne pas s’appuyer sur une partie du système et de ne pas y poser
d’objets lourds.
Mit diesem Zeichen wird der Benutzer darauf aufmerksam
gemacht, daß sich niemand gegen einen bestimmt en Bereich
des Systems lehnen sollte oder daß keine schweren
Gegenstände darauf plaziert werden sollten.
Este símbolo advierte al usuario que no se deben colocar objetos
pesados sobre un área del sistema, ni tampoco ésta debe usarse
como apoyo.
*
†
•
‡
*
†
•
This symbol is intended to alert the user of the presence of
important instructions in the literature accompanying the system.
Ce symbole est conçu pour avertir l’utilisateur que des
instructions importantes sont fournies dans la documentation
livrée avec le système.
Mit diesem Zeichen wird der Benutzer darüber informiert, daß in
der Dokumentation wichtige Anleitungen zum System zur
Verfügung stehen.
Este símbolo indica al usuario la presencia de instrucciones
importantes proporcionadas en la información impresa incluida
con el sistema.
This symbol is intended to alert the user of the system to the
presence of uninsulated “dangerous voltage” within the product’s
enclosure that may be of sufficient magnitude to constitute a risk
of electric shock to persons.
Ce symbole avertit à l’utilisateur du système que ce produit
comprend la présence de “voltages dangereux” sans isolation
dont la magnitude est suffisante pour poser un risque de
décharge électrique aux individus.
Mit diesem Zeichen wird der Benutzer des Systems davor
gewarnt, daß sich innerhalb des Produkts nicht isolierte
“gefährliche Spannungen” befinden, die eventuell stark genug
xiii
sind, um für Personen eine Gefahr eines elektrischen Schlages
darzustellen.
‡
V symbolizes voltage
*
†
V symbolise la tension
V Symbol für Netzspannung
•
‡
V significa Voltaje
A symbolizes ampereage
*
†
A symbolise l’intensité du courant
A Symbol für Stromstärke
•
‡
A significa Amperaje
Hz symbolizes Hertz.
*
†
Hz symbolise Hertz.
Hz ist das Zeichen für Hertz.
•
‡
Hz simboliza Hertz.
Este símbolo advierte al usuario del sistema que se hallan
presentes “voltajes peligrosos” no aislados de suficiente potencia
para presentar un riesgo personal de descarga eléctrica.
Zeichen für Wechselstrom.
significa corriente alterna.
symbol indicates type “B” equipment
Ce symbole indique un équipement de type “B”
Dieses Zeichen zeigt Geräte des Typs “B” an
Este símbolo indica equipo tipo “B”
*
†
†
AP
•
‡
These symbols indicate that this product is not to be
AP
used in the presence of flammable anesthetics.
G
Ces symboles indiquent que ce produit ne doit pas être
utilisé en présence d’anesthésiques inflammab les.
Dieses Zeichen zeigt an, daß dieses Produkt nicht in
der Nähe feuergefährlicher Narkotika verwendet
werden darf.
Estos símbolos indican que este producto no debe
usarse en la presencia de anestésicos inflammables.
*
†
•
‡
*
†
•
‡
*
•
‡
*
†
symbolizes “off” for a part of the equipment.
symbolise “désactivé” pour une partie du matériel.
Für ein Teil des Geräts bedeutet dieses Zeichen “AUS”.
significa “desactivado” para una parte del equipo.
symbolizes primary grounding point of equipment
Ceci symbolise le point de mise à la terre principal de
l’équipement
Symbol für den Haupterdungspunkt des Gerätes
Esto simboliza el punto de tierra primario del equipo
indicates ground connection point
Ce symbole indique le point de connexion à la terre
Symbol für den Punkt der Erdungsverbindung
Este símbolo indica el punto de conexión a tierra
Grounding wires, studs, and terminals are an important safety feature of
this equipment and should not be altered in any way. If you suspect a faulty
ground connection or any other problem related to grounding, discontinue
use and contact VTEL or your service provider.
Les fils de mise à la terre, les goujons et les terminaux constituent des
mesures de sécurité importantes pour cet équipement et ne doivent en
aucun cas être changés. Si vous pensez avoir une connexion à la terre
défectueuse ou tout autre problème lié à la mise à la terre, cessez d’utiliser
xv
le système et contactez VTEL ou votre fournisseur de service.
Erdungsleiter, Stiftschrauben und Masseklemmen sind wichtige
•
Sicherheitsmerkmale dieses Gerätes und dürfen in keiner Weise
verändert werden. Wenn eine fehlerhafte Erdungverbindung oder ein
anderes Erdungsproblem vermutet wird, ist der Betrieb einzustellen und
VTEL oder Ihr Dienstanbieter zu benachrichtigen.
‡
Los terminales, pernos y cables a tierra son una característica de
seguridad importante de este equipo y no deben alterarse. Si usted cree
que existe una conexión a tierra defectuosa u otro problema relacionado
a la conexión a tierra, discontinúe el uso y comuníquese con VTEL o con
su suministrador de servicios.
*
†
•
‡
*
†
•
‡
*
†
•
‡
*
†
•
‡
symbolizes video input
Ceci symbolise l’entrée vidéo
Symbol für Videoeingang
Esto simboliza entrada de video
symbolizes video output
Ceci symbolise la sortie vidéo
Symbol für Videoausgang
Esto simboliza salida de video
Symbol für Audioeingang
Esto simboliza entrada de audio
symbolizes audio output
Ceci symbolise la sortie audio
Symbol für Audioausgang
Esto simboliza salida de audio
xvi
*
‡
†
•
Periodic Safety Testing
*
†
Périodicité des tests de sécurité
symbolizes microphone connector
Ceci symbolise le connecteur du microphone
Symbol für Mikrofonanschluß
Esto simboliza conector de micrófono
Warning:Earth leakage current and the ground integrity of the
metal chassis should be tested regularly, at least
once every six months, by trained personnel. If the
system fails either of these tests, discontinue the use of the equipment immediately and contact
your service provider.
Earth Leakage Current should not exceed 100
microAmperes when measured in compliance with
EN60601-1 and IEC 601-1.
Ground Integrity, when measured at 30 Amperes
should not exceed 0.1 Ohm from the ground pin on
the AC plug, to all parts of the metal chassis, including
drawers, shelves, and camera arm (if provided).
Mise en Garde: Au moins tous les six mois, le courant de fuite et
l’intégrité de la mise à la terre du châssis métallique
devraient être testés par un personnel dûment
formé à cet effet. Si l’équipement ne passe pas l’un
ou l’autre de ces tests, son emploi doit être immédiatement interrompu , et le responsable
chargé de l’entretien doit être contacté.
Pour être conforme aux normes EN60601-1 et IEC601-1, le courant de fuite ne doit pas dépasser 100
microa mpères.
L’intégrité de la mise à la terre, mesurée à 30
ampères, ne doit pas dépasser 0,1 Ohm de la borne
de terre sur la fich e CA, à tous les secteurs du châssi s
métallique, à savoir les tiroirs, étagères et bras de
caméra (optionnel).
xvii
Regelmäßige Sicherheitstests
•
Warnung:Der Erdschlußstrom sowie die Erdungsintegrität
des Metallchassis sind regelmäßig (mindestens alle
sechs Monate) von geschultem Personal zu
überprüfen. Wenn das System einen dieser Tests
nicht besteh t, i s t die Benutzung dieses Geräts sofort einzustellen und der Kundendienstservice
zu benachrichtigen.
Der Erdschlußstrom darf bei Messungen gemäß
EN60601-1 und IEC 601-1 den Wert von 100
Mikroampere nicht überschreiten.
Die Erdungsintegrität darf den Wert von 0,1 Ohm,
gemessen bei 30 Ampere, nicht überschreiten. Dies
gilt für den Erdungsstift des Steckers und alle
Bestandteile des Metallchassis, einschließlich der
Schubladen, der Regale und des Kameraarms (falls
vorhanden).
‡
Prueba de seguridad periódica
Aviso:El personal capacitado debe realizar una prueba de
seguridad con regularidad, por lo menos cada seis
meses, de la corriente de fuga a tierra y la integridad
de la conexión a tierra del armazón metálico. Si los
resultados de cualquiera de estas pruebas no son
los requeridos, debe dej ar de usar el equipo inmediatamente y ponerse en contacto con su
proveedor de servicio.
La corriente de fuga a tierra no debe exceder 100
microamperios cuando se mide en conformidad con
los estándares EN60601-1 y IEC 601-1.
La integridad de la conexión a tierra, cuando se mide
a 30 amperios, no debe exceder 0,1 ohm de la patilla
de tierra del enchufe de CA a todas las piezas del
armazón metálico, incluyendo sus cajones,
estantería y el brazo de la cámara (si lo tiene).
xviii
About This Handbook
Who should use this handbook. . . . . . . . . . . . . . . . . . . . . . . xxvii
The Enterprise Series™ HS 2000 system is an open architecture,
PC-based ruggedized videoconferencing system manufactured by
VTEL™ Corporation. VTEL’s AppsView™ software program, along
with VTEL’s HS Touch™ touch screen user interface, controls
the videoconferenc ing functions of the system.
Who should use this handbook
This handbook is for people who configure and manage an Enterprise
Series HS 2000 system at the site where the system is located.
This handbook assumes that you are familiar with basic
telecommunications connectivity terms and concepts and that you know
how to use Windows
®
95.
Who should use this handbookxxvii
About This H andbook
Other HS 2000 system documentation
This book conta ins information for use only by the Enterprise Series
HS 2000 system administrator.
The companion book for this handbook is the HS 2000 Installation and User’s Handbook, which contains information about how to install and
use the HS 2000, AppsView, and HSTouch to perform videoconferencing
tasks. The HS 2000 Installation and User’s Handbook should be placed
where it will be within easy reach of videoco nferencing partici pan t s.
Online documents
These online doc uments are included with the Enterprise Series HS 2000
System:
HS 2000 System Adm inistrator’s Handbook
■RS-366 Interface Description (states.doc)
Describes implementation
.
of standards that apply to the connection between the Enterprise
Series system and an external network interface via a DDM card.
(The RS-366 inte rfac e co ntr o ls call setup and dialing through the
DDM card.) Use this document as a reference when w ork i ng wi th
vendors of external network interface equipment.
■ISDN Positioning Interaction
(isdnbri.doc). Provides information
about configuring an ISDN switc h. Read this document if your
Enterprise Se ries system is equipped with a Promptus Single or Quad
BRI card.
For information about reading the state s.doc and isdnbri.doc files, see the
next section, “Reading online documents with WordPad.” .
xxviiiOther HS 2000 system documentation
HS 2000 System Adm inistrator’s Handbook
Reading online documents with WordPad
T o read the sta tes. doc and isdnbri. doc fil es, use the Microsoft
application:
About This Handbook
®
WordPad™
To display the
Windows 95
taskbar, press
-
Esc
.
Ctrl
Getting help
1
To launch WordView, click the Start button on the Windows 95
taskbar, then select Programs.
2
Select Accessories, then select WordPad.
3
In WordView, open the online document you need:
c:\vtel\appsview\states.doc
c:\vtel\appsview\isdnbri.doc
Contact your VTEL reseller or authorized service provider if you need to
order repla cement parts or optional hardwa re and software, or if you ha ve
a technical question about the HS 2000 system, the AppsView software,
or the HSTouch user interface. .
Getting helpxxix
About This H andbook
HS 2000 System Adm inistrator’s Handbook
xxxGetting help
System Overview
This chapter provides basic information about your Enterprise Series
HS 2000. It also gives you an overview of typical VTEL system
administration tasks.
Configuring the syste m
This section lists conf iguration tasks you need to perform after your
new system is set up.
To configure the system, follow the instructions in Chapter 2,
“Configuring AppsView,” then complete the configuration by
performing the procedures described in Chapter 3, “Preparing for
Videoconferences.”
1
Configuring the system1
Chapter 1. System Overview
HS 2000 System Adm inistrator’s Handbook
For information
about installing
optional software,
see the instructions
included with the
optional software.
Note:
You do not need to install AppsVie w softwar e.
If you are setting up a new system, VTEL has already
installed all the software on the syste m.
If you ever need to re-install the software, see the
HS 2000 User and Installation Handbook.
Guide to basic configuration tasks
The following steps list the basi c tasks you’ll need to perform
to set up your system.
Note:
1
This book includes informatio n about other ways
you can customize the system, but the followi ng steps
describe basic configuration tasks.
Perform all the procedures described in Chapter 2, “Configuring
AppsV iew,” including setting up a default communications profile
(“Selecting a defaul t communi cations profile” on page 25).
2
If necessary, set up a communications profile for an atypical type
of connection (“Adding or customizing a profile for your site” on
page 32).
3
Set up Address Book entries (“Sett ing up Address Bo ok entries” on
page 54).
4
Set up Speed-Dialer buttons ( “Set ting up Speed-Dialer site buttons”
on page 56).
5
Set default camera and preset camera positions (“Setting camera
preset positions” on page 57).
2Configuring the system
HS 2000 System Adm inistrator’s Handbook
6
Fine-tune audio and video settings (“Fine-tuning audio settings” on
page 60 and “Fine-tuning video settings” on page 62).
Performing backups
It is a good idea to back up data files (such a s slide files) at least once a
week. For more information, see the sect ion in the Windows 95 user’s
guide that discusses how to back up data files.
Troubleshooti ng
If you encounter a problem when using the HS 2000 system,
first check the problems and solutions described in Chapter 5,
“Troubleshooting.”
Chapter 1. System Overview
If you can’t find the answer to the proble m there, call your VTEL
representati ve.
Performing backups3
Chapter 1. System Overview
HS 2000 System Adm inistrator’s Handbook
Powerin g up the sys te m an d sta rt in g App sVie w
1
Turn the HS 2000 system on by pressing the on/off button (located
inside the peripheral stor age area) to the On position.
Windows 95 and AppsView start up automatica lly, and the AppsV ie w
icon appears in the lower right corner of the screen.
Powering down the system
If you need to power down the HS 2000 system:
1
If a call is in progress, hang up.
2
Use the right mouse button to click the AppsView icon,
then select Exit A p psView Immediately.
3
To display the
Windows 95
taskbar, press
Ctrl-Esc
keyboard.
on the
Shut down Windows by cli cking the Windows 95 Start button, then
selecting the Shut Down option.
Note:
You cannot shut down W indows 95 until you close
AppsV iew .
4
Turn off the system by pressing the on/off switch to the Off position.
(The on/off swit ch is located inside the cabinet.)
Note:
If you want to restart the system, wait 30 seco nds after
turning it off befor e you turn it on again.
4Powering up the system and starting AppsView
HS 2000 System Adm inistrator’s Handbook
Software overview
This diagram shows the main software components of the
HS 2000 system:
Chapter 1. System Overview
Software overview5
Chapter 1. System Overview
The videoconferenci ng applications run on the Microsoft Windows 95
operating system. The following list briefly describ es each app lication.
AppsViewVTEL software required for all
HS 2000 System Adm inistrator’s Handbook
videocon fere n cin g fun ctions.
Chair Control
requires the use of
a Multipoint Control
Unit (MCU).
AppsShare
™
Software that enables application sharing.
HSTouchTo uch screen user interface software.
PenPal Optional VTEL software that lets users save
for Windowsand annotate video slides and snapshots.
Includes an electron ic table t, pen, and tablet
overlays.
Chair Optional VTEL software that facilitates
Controlmultiway conferences.
for dual-monitor ESA systems.
SmartView automatically captures a
document, sends it to the remote site, and
returns control to the loca l camer a.
Phone AddOptional VTEL software that enables
telephone caller to participate in a
videocon fere n ce wi th you r site.
DiagnosticsVTEL software that you or a service
representati ve can use to ide ntify problems
with system components.
RemoteOptional software that facilitates remote
Diagnosticsdiagnostic tests.
6Software overview
HS 2000 System Adm inistrator’s Handbook
Hardware overview
These are the main hardware components inside the cabinet of the
HS 2000 system:
Chapter 1. System Overview
Pentium™ PC
expansion unit
enhanced master box
Hardware overview7
Chapter 1. System Overview
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbb
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddd
dddddddddddddddd
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaa
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccc
cccccccccccccccc
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbb
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddd
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaa
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccc
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
bbbbbbbbbbb
bbbbbb
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
d
ddddddddddd
dddddd
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
aaaaaaaaaaa
aaaaaa
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
c
ccccccccccc
cccccc
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddddd
d
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccccc
c
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
bbbbbbbbbbbbbbbbbbbbbbbbbbbbb
b
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
ddddddddddddddddddddddddddddd
d
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
a
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
ccccccccccccccccccccccccccccc
c
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbb
ddddddddddddddddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddddddddddddddddd
ddddddddddddddddddddddddddddddddddddddddddddd
ddddddddddddddddddddddd
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
aaaaaaaaaaaaaaaaaaaaaaa
ccccccccccccccccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccccccccccccccccc
ccccccccccccccccccccccccccccccccccccccccccccc
ccccccccccccccccccccccc
Other main components include the se items:
HS 2000 System Adm inistrator’s Handbook
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbbbbbb
ddddddddd
aaaaaaaaa
ccccccccc
b
d
a
c
bbbbb
ddddd
aaaaa
microphone
HSTouch panel
camera
ccccc
mouse
keyboard
8Hardware overview
HS 2000 System Adm inistrator’s Handbook
PC
The PC contains the CPU, hard disk drive , RAM, and other standard PC
components, as w ell as the proprietary VTEL board se t described in the
next section.
Enterprise Series system board set
The following illustration shows the VTEL boards located inside the PC:
Chapter 1. System Overview
serial
VGA
codec
(and audio
daughterboard)
LAN
video
(and optional
video
daughterboard)
network
adapter
modem
sound
Hardware overview9
Chapter 1. System Overview
VGA board
The VGA board is a PCI-type graphics adapter with 2 megabytes of
RAM. The VGA board is cabled to the video board, where vide o and
VGA graphics are merged.
Video board
The video board (and optional daughterboard) is used with the codec
board and a compatible VGA board. The video board perfo rms thes e
functions:
■Px64 video decoding
■VGA scan conversion
■chroma-key merging of VGA and live video
The video daughterboard inc ludes an additional video input and video
output to enable the use of dual monitors.
HS 2000 System Adm inistrator’s Handbook
Codec board
The codec board (and audio daughter board) is a PCI board
that incorporates a video codec, an audio subsystem, a communications
protocol, and a f raming pr ocessor. The codec board includes a video i nput
and performs Px64 video encoding.
The codec board also incorporates a communications processor for
transmission of digital audio/vide o to various system resour ces, including
the network adapter. The audio daughterboard includes two audio inputs
and two line-level audio inp uts, and performs digital audi o compression/
decompression and acoustic echo cancellation.
10Hardware overview
HS 2000 System Adm inistrator’s Handbook
Network adapter
The network adapter is an ISA board that serves as a telecom wide area
network (WAN) adapter for connecting the system to remote site s. This
board is directly connec ted to the codec board via an internal MVIP
ribbon cable. Multiple network adapter options enable the Enterprise
Series HS 2000 system to support a number of different networking
solutions and protocols.
Expansi on un i t
The expansion unit is a rack-mountable chassis th at conta ins components
that route peripheral video and a udio equipment t o system resources. The
unit provides five vid eo inputs and four vide o outputs for general purpose
uses. It also provides video and audio connections to the system’s codec
and video boards.
Audio components of the unit support three microphone inputs, two
line-level audio inputs (one mixed with microphones), and two line-level
audio outputs.
Chapter 1. System Overview
Hardware overview11
TO MOUSE
PART OF 605-1445-01
PART OF 605-1445-01
605-1365-01
TO KEYBOARD
605-1366-01
NETWORK ADAPTER
VGA
CODEC
VIDEO
SONY MONITOR
605-1444-10
605-774-13
SONY PTZ
POWER SUPPLY
605-1444-09
PART OF 605-1445-01
UNTIL FUNCTION IS MADE OPERATIONAL)
LABEL 340-371-01 (TO HIDE PORT
ITEMS SHOWN ARE FOR REFERENCE ONLY.
INSTALLED IN THE FIELD.
(QBRI)
Y/C
IN
Y/C
VIDEO
IN
AUDIO
VIDEO
ININ
AUDIO
IN
OUT
OUT
OUT
IN
LINE ALINE B
PHONE CABLE FOR FUTURE UPGRADE
STORED IN CABLE BOX
RS-232 FOR FUTURE UPGRADE
STORED IN CABLE BOX
RS-449 FOR FUTURE UPGRADE
STORED IN CABLE BOX
STORED IN CABLE BOX
COMM CABLES
605-1547-01
SWITCHED POWER
605-1548-01
605-1441-02
605-1549-01
605-1544-01
605-921-13
605-1550-01
605-1563-02
605-1543-02
605-1066-04
605-1067-02
605-1067-01
605-1545-01
605-1546-01
605-1563-03
605-1563-01
605-1543-01
LAN CABLE FOR FUTURE UPGRADE
STORED IN CABLE BOX
OUTIN
AUDIO
VIDEO
MIC 2
LAN
PHONE SET
PHONE WALL
RS 232
RS 449
S-VIDEO
MAIN
COMPOSITE
PREVIEW
IN
OUT
SONY PTZ CONTROL
TO 005-113-01
POWER SUPPLY
605-1567-01
SONY PTZ
ARM CAMERA
EM 232 BOX
RS232RS232/422
PWR
AXlink
MINI TOUCH PANEL
IR RECIEVER
PART OF 605-1564-01
PART OF 605-1564-01
PART OF 605-1564-01
CONNECTION
POWER SWITCH
PART OF 605-1564-01
PHONE
1
CAMERA
234
LINE
LINE
1
MONITOR
2 3
LINE
C B
MICROPHONE
1
2
3
VCR
CODEC
AUDIO
+12VDC
REVAS/N
100ma
P/N 005-1600-01
+
EnterpriseSeries
TELCO
TELEPHONE
CTRL-S
REMOTE
POWER
MAINAUX
CODEC
VIDEO
A
PC
TeamTMConferencing
TM
FAX LINE
FOR FUTURE UPGRADE
COM1
COM2
LPT1
LPT2
KEYBRD
MOUSE
1
23
4
5
67
8
NETWORK ADAPTER
MODEM
SOUND
SERIAL
VGA
CODEC
LAN
VIDEO
Configuring AppsView
Follow the steps in this chapte r to set up AppsView. To complete
the configuration, perform the procedures described in Chapter 3,
“Preparing for Videocon fere n ces. ”
Setting up AppsView for the first time
If you are setting up AppsView for the first time, when you turn on the
system, the Configuration program automatically opens to the Welcome
tab. Go to step 5 on page 15.
2
Setting up AppsView for the first time13
Chapter 2. Configuring AppsView
Accessing configuration windows
1
Click the AppsVie w ic on to display the AppsView toolbar.
2
Click the System Tools button on the AppsView toolbar to display
the Configuration toolba r.
3
On the Configuration toolbar, click the Set Con fi g urati o n button.
The Advanced Interface Setup window opens:
HS 2000 System Adm inistrator’s Handbook
14Accessing configuration windows
HS 2000 System Adm inistrator’s Handbook
Chapter 2. Configuring AppsView
The other options in the
Appearance window are
described in “Set ti ng up
AppsView display
options” on page 44.
4
Click the Launch Advanced Config Program button. The
Configuration window opens an d displays the Welcome tab.
5
Click the tab for the configuration window you need.
If you are setting up your system for the first time, click the
Next button to begin configuri ng the system.
Accessing configuration windows15
Chapter 2. Configuring AppsView
Identifying your site
1
From the Configuration window, select the Site Info tab.
HS 2000 System Adm inistrator’s Handbook
2
Enter your location’s site name in the Site Info window.
Note:
The Site Name is the identifier the optional Chair
Control application will use for your site. This is
the name that identifies the site to participants in
Chair Control videoconferences.
3
If you are setting up your system for the first time,
click the Next button to continue configuring the system.
16Identifying your site
HS 2000 System Adm inistrator’s Handbook
Hardware and ISDN interface connections
Configuring a new system
If you are setting up a new system, follow the steps in this section
to configure the hardware. (If you are adding new hardware, see
“Configuring additional hardware” on page 19.)
1
From the Configuration window, select the Hardware tab.
Chapter 2. Configuring AppsView
Hardware and ISDN interface connections17
Chapter 2. Configuring AppsView
2
If your system uses a DDM interface, click the Communications tab
(or Next if you are performin g initial system configuration) to
proceed. (See “ Setting communications parameters” on page 24.)
If your system u ses a Quad B RI int erface, se t t he ISDN swit ch type
(such as NI-1 or NET3). If you do not know the switch type, check
with the telephone company tha t provides your ISDN service.
If your ISDN connection requires the use of Directory Numbers
(DNs) or Service Provider IDs (SPIDs), e nter the DN or SPID for
each ISDN line.
DNs and SPIDs are assigned by the telephone company that installs
your ISDN line. If you do not know these numbers, contact the
telephone company that installed the ISDN line, or contact your
VTEL reseller.
Click the Communication s tab (or Next if you are performing initial
system configuration) to proceed. (See “Setting communications
parameters” on page 24.)
HS 2000 System Adm inistrator’s Handbook
18Hardware and ISDN interface connections
HS 2000 System Adm inistrator’s Handbook
Configuring additional hardware
Chapter 2. Configuring AppsView
If you are setting up
a new HS 2000
system, skip this
section
Continue setup by
going to page 24.
.
If you are installing new VTEL boards or boards from other vendors,
follow the instruct ions in this section to configure the new hardware.
Notes:
You do not need to perform step 1 or step 2 in this
section if you are installing plug- a nd-play or PCI
boards, including the VTEL Enterpri se TC video card
or the VTEL Enterprise TC codec card.
You do need to perform step 1 and step 2 if you are
installing non-pl ug-and-play ISA boards, except for the
VTEL teleconferencing networ k adapte rs, which are
automatically installed during AppsView installation.
If instructions are included with other vendors’ ISA
boards, follow the Windows 95 instructions included
with those boards. If instruct ions for using the board
with Windows 95 are not incl ude d, co ntact the board’s
manufa ctu rer fo r information.
Hardware and ISDN interface connections19
Chapter 2. Configuring AppsView
1
You do not need to
perform this st ep
if you are install ing
plug-and-pl ay or
PCI boards, including
VTEL TC video boards,
VTEL TC codec boards,
and the standard
configuration VTEL
T eleconfere ncing Network
Adapter board.
Use the Wind ows 95 Add New Hardware Wizard to set up the new
hardware in Windows, as described in this step.
■Click the Windows 95 Start button.
■Select Settings, then select Control Panel.
■Open the System window, then select the
■Select Other Devices, then select VTEL as the manufacturer.
■Select the hardware that matc hes the board you are installing.
HS 2000 System Adm inistrator’s Handbook
Device Manager tab.
You do not need to
perform this st ep
if you are install ing
plug-and-pl ay or
PCI boards, including
VTEL TC video boards,
VTEL TC codec boards,
and the standard
configuration VTEL
T eleconfere ncing Network
Adapter board.
2
If the wizard detec ts a res o urce u s age co n flic t bet ween existing
hardware and t he new ha rdware, s elect Continue to run the Har dware
Conflict Tr oubleshooter.
You may need to change settings for the existing hardware or for the
new hardware, or make additional resources available.
It is likely that you will need to change IRQ settings to allow for the
new hardware. If the system does not need to use a printer port,
disable LPT1, which frees IRQ 7 for use. If the system does not use a
secondary IDE controller, disable it, which makes IRQ 15 available.
20Hardware and ISDN interface connections
HS 2000 System Adm inistrator’s Handbook
Use the BIOS se tup program to change IRQ settings as follows:
Reboot the system. When you see the memory test running,
click the F1 key.
■Under Advanced/Peripheral Configuration, disable the
Secondary IDE controlle r and/or the Parallel Port.
Chapter 2. Configuring AppsView
Use
In Use by ISA
if the IRQ will be used
by a legacy ISA card.
Use
Available
IRQ will be used by
a PNP ISA card or a
PCI card.
if the
■Under Advanced/Plug and Play Configuration, set IRQ 7
and/or IRQ 15 to In Use by ISA or to Available.
If resources used by VTEL ISA boards must be changed, select Basic Configuration 1 or Basic Configuration 2, which allows you to
specify different Input/Output Range and IRQ settings.
For the I/O Range, make sure the switch settings on the board match
the beginning value you set in Windows 95.
Hardware and ISDN interface connections21
Chapter 2. Configuring AppsView
g
3
From the Configuration window, select the Hardware tab.
HS 2000 System Adm inistrator’s Handbook
4
Set the Interface type.
Interface Type
SettingDescription
Quad BRINetwork adapter for ISDN BRI networks.
Sin
le BRINetwork adapter for ISDN networ k (1 pl ug, 2
lines).
DDMNetwor k adap ter tha t suppor ts T1, swi tched dua l
56/64, and ISDN BRI networks.
22Hardware and ISDN interface connections
HS 2000 System Adm inistrator’s Handbook
5
Set the ISDN switch t ype (such as NI-1 or NET3) . If you do no t know
the switch type, check wit h the te lephone company th at provide s your
ISDN service.
6
Enter the Directory Number and Service Provider ID (SPID) for each
ISDN line.
DNs and SPIDs are assigned by the telephone company that installs
your ISDN line. If you do not know these numbers, contact the
telephone company that insta lled the ISDN line, or contact your
VTEL reseller.
Chapter 2. Configuring AppsView
Hardware and ISDN interface connections23
Chapter 2. Configuring AppsView
Setting communications parameters
This sectio n explains how to set up a default communic ati ons profile and,
if necessary, alternate profiles.
You can use one of these methods to set a default AppsView
communications profile based on your system’s hardware and the
types of connections your site usually makes:
■Select one of the default prof ile s provided with AppsView.
■Copy a default profile, save it unde r a new file name, the n modi fy
configuration parameters for your site’s communications se tup.
■Create a new communications profile.
HS 2000 System Adm inistrator’s Handbook
Note:
T o configure communica tions settings, you must know
the types of external equipment to which your system
is connected (for example, diale r, MUX, or IMUX).
You can also set up alternate profiles for use in atypical situations
(for example, if your system sometimes use s a dial-out prefix that is
different from its usual prefix, or occasionally uses a single port call
when your site usually makes dual port calls). See “Adding or
customizing a profile fo r your site ” on page 32.
24Setting communications parameters
HS 2000 System Adm inistrator’s Handbook
Selecting a default communications profile
Chapter 2. Configuring AppsView
See “Setting up
AppsView for the first
time” on page 13.
Do not change the
properties of a default
profile. If you were
ever to re-inst all
AppsView, settings
you changed in a
default conf iguration
might be overwritte n.
Also, changing a
default profil e m ay
make it more difficult to
troubleshoot problems
that may arise.
1
From the Configuration window, select the Communications tab
(or click Next from the Hardware tab).
2
In the list of profiles, highlight the profile that seems to best match
your system’s equipment.
Proceed with steps 3 through 6 to make sure the properties of the
profile you’ve selec ted are the best ones for your system.
If any property setting does not meet your needs, do not change the setting. Instead, follow this pr ocedure:
■Return to the Communications tab.
■Create a new profile by following the instructions in “Adding or
customizing a profile fo r your site ” on page 32.
Setting communications parameters25
Chapter 2. Configuring AppsView
3
Click the Properti es button to open the Edit ing Profile window.
HS 2000 System Adm inistrator’s Handbook
26Setting communications parameters
HS 2000 System Adm inistrator’s Handbook
g
g
g
g
g
g
g
g
g
g
g
Select options in the Protoc ols window a s described in the
following table:
Protocols options
OptionDescription
Chapter 2. Configuring AppsView
Auto Confi
Comm ProtocolFor communication with another
Audio Al
Video Al
orithmIn North America, selecting a low
orithmEnterpr ise Series syst ems use th e
Selecting this option causes
AppsView to determine the best
communications settin
call when the c all is di aled. (If Aut o
Confi
is selected, you ca nnot
chan
e Audio Algorithm or Comm
Protocol set ti n
VTEL system, sel ect VTEL HDLC.
For communication with another
type of system, select H.221.
al
orit hm
(16 Kbps) allows more bandwi dth
for video.
In Japan, select the hi
available al
H.261 al
s.)
orithm.
orithm.
for each
hest
Setting communications parameters27
Chapter 2. Configuring AppsView
4
Select the Line Speeds tab.
HS 2000 System Adm inistrator’s Handbook
In the Line Speeds window, make sure the options selected are
suitable for your configuration (as described in the following table),
then click the Dialing tab to proceed.
28Setting communications parameters
HS 2000 System Adm inistrator’s Handbook
g
g
g
g
g
OptionDescription
Chapter 2. Configuring AppsView
Possible Li n e
Speeds
and
Supported Line
Speeds
Setup Prefix
Setup Suffix
A T&T with an
Ascend
For each line speed yo ur system supports:
1. Select the line speed i n the list of Possible
Line Speeds.
2. Dra
From the Supported Li ne Speeds list, select the
line speed to use fo r the default profile.
Selectin
dial-out pref ix or suffix to use onl y wit h that
selected line rate.
If you sel ect the AT&T with an Ascend option,
you can enter a dif ferent prefix to replace the
default 011 prefix. (For example, if a user enters
the number for your UK office, which be
the 011 prefix, but your network is set up to
reco
entry overrides the Enterpri se Series system’s
01 1 default settin
completed.)
it to the Supported Li ne Speeds li st and
drop it there (or press the Add button).
certain line rates allows you to enter a
ins wi th
nize the pref ix 071 inste ad of 011, your 071
, enabling the user’s call to be
Setting communications parameters29
Chapter 2. Configuring AppsView
g
g
g
g
5
In the Dialing window, chec k the options described in the table, then
click OK.
HS 2000 System Adm inistrator’s Handbook
Dial i ng options
OptionDescription
Dial ModeSelect the dial mode appropriate for your
system’s type of dialin
Sin
le Port CallsSelect Port A or Port B.
Two communications ports are on the back of
the PC. For calls that use hi
384 Kbps o r 768 Kbps, only one port is required.
Use this field to select which port you will use.
Calls that use 112 Kbps or 128 Kbps line rates
typically require both ports, in which case no
settin
is required for this field.
interface.
h line rat es, su ch a s
30Setting communications parameters
HS 2000 System Adm inistrator’s Handbook
Dialing options (continued)
OptionDescription
Dial-OutEnter a prefix or a suf fix, if neces sary. For
Chapter 2. Configuring AppsView
example, if you r system is connected to a PBX,
you may need to enter the pr efi x 9 to di al out.
Auto Answer
Video Call
Auto Answer
Audio C all
6
If the default se tti ngs in all th e prop ert ie s windows are correct
Place a check mark in this box if you want
AppsView to alway s automatically answer every
video call it receives. Click the check box to add
or clear the check mark for this option.
If your HS 2000 system includes the Phone
option, pl ace a check mark in this box if you wan t
AppsView to al ways automatically answer every
audio (tel ephone) call it r ece iv es . Click the chec k
box to add or clear the check mark for this
option.
for your system:
■Return to the Communications window and make sure
your default profil e is sele cted in the Default Profile field.
(See “Accessing configuration windows” on page 14.)
■Select the Cameras tab (or Next if you are performing initial
system configuration) to continue configuring the system.
(See “Configuring camera, moni tor, and VCR settings” on
page 34.)
Setting communications parameters31
If any of the defaul t setti n gs a re not correc t:
Follow the steps in the next secti on, “Adding or customizin g a profile
for your site ” on page 32 to create a new profile.
Chapter 2. Configuring AppsView
Adding or customizing a profile for your site
The default setting s for the pr ofile s liste d in the Communicati ons window
may not match the requirements for your syste m’s hardware or its
connection types.
T o set up a custom profile for your system, follow these steps:
1
From the Configuration window, select the Communications tab.
2
If the settings for a profile in the Profiles list match many
(but not all) of the setting s required by your system,
select the profile, then press Copy.
If you cannot find a profile in the Profiles list with settings that
closely match the settings r eq uired by your system, select Add.
3
Enter the name of your new profile.
HS 2000 System Adm inistrator’s Handbook
4
Highlight the name of the new profile in the Profiles list.
5
Press the Properties button.
6
Select options in the Protoc ols window, as described in the table
on page 27.
32Setting communications parameters
HS 2000 System Adm inistrator’s Handbook
7
Select Line Speed and Dialing opti ons as described in ste ps 4 through
6 of the previous section, “Selecting a default communications
profile” (page 25). Click Finish to complete your setup.
To use the new profile as the default:
■Select the new profile in the Default Profile field on the
Communications tab (page 25).
■In the Address Book window, select the Use Default profile
option. (See “Entering a new site in the Address Book” on
page 55).
To use the new profile as an alternate profile:
See “Entering a new site in the Address Book” on page 55.
8
If you are setting up your system for the first time, click
the Next button in the Communications window to continue
configuring the system.
Chapter 2. Configuring AppsView
Setting communications parameters33
Chapter 2. Configuring AppsView
HS 2000 System Adm inistrator’s Handbook
Configuring camera, monitor, and VCR settings
1
Select the Cameras tab from the Configuration window.
2
Select the type of cameras your system uses.
34Configuring camera, monitor, and VCR settings
HS 2000 System Adm inistrator’s Handbook
The standard camera includ ed with the HS 2000 system is an S-V ide o
camera. Cameras not purchased from VTEL may be composite
cameras.
If your syste m includes multiple Sony PTZ cameras or m ultiple
CameraMan cameras connected in a daisy-chain, select the
appropriat e cam er a man u fa ct urer fro m the Camera 1 PTZ Camera
drop-down list, then select Same as Camera 1 from the other PTZ
Camera drop-down lists.
If your syste m includes a Canon camera, that camer a is the o n ly
PTZ camera your system can include. Canon cameras cannot be
connected in a daisy-chain.
3
Select the type and number of monitors your syste m includes.
4
Select the video format standa rd your system uses:
NTSC (North American) or PAL (European).
Chapter 2. Configuring AppsView
5
If your system does not include a VCR: select None.
If your syste m includes a VCR:
select the video type, Composite or S-Video.
Configuring camera, monitor, and VCR settings35
Chapter 2. Configuring AppsView
6
Choose whether to enable Allow VCR control from remote site.
When you record VCR during a conference:
•
•
When you play the VCR during a conference:
•
•
HS 2000 System Adm inistrator’s Handbook
With this opt ion disabled, the sound won’t be interr upted
during your recording. (The rem ote site doesn’t change the
audio, even if they choose to view the VCR instead of the
camera source you are sending.)
If the option is enabled, and the remote site changes the
video source to the VCR, the VCR stops recording the
conference.
With thi s option enabled, audio always matches video.
If the option is disabled, audio c ontinues to come from the
VCR no matter what video source the remote site selects.
7
If you are setting up your system for the first time,
click the Next button to continue configuring the system.
36Configuring camera, monitor, and VCR settings
HS 2000 System Adm inistrator’s Handbook
Configuring audio delay s
Chapter 2. Configuring AppsView
Video and audio
synchronization is
referred to as
That is, the movement
of a person’s lips
match the words they
are saying.
lip sync
The HS 2000 system automaticall y compensates for delay between video
.
and audio. In certai n circu m stances you may want to add a delay
to the audio. The size of the delay varies acc ord ing to these factors:
■line rate
■amount of motion in the video (The more motion, the longer the
delay; the less motion, the shorter the delay.)
If you need to change the HS 2000 system default audio de lay settings
(specific for each li ne rat e) to improve lip sync, follow
these steps:
1
Select the Audio Delays tab from the Configur ation window .
Configuring audio delays37
2
Select a line rate.
Chapter 2. Configuring AppsView
3
Move the Rcv Delay and Xmt Delay slider bars to increase
or decrease the delay, then click OK.
4
Repeat steps 2 and 3 for each line rate for whic h you want
to configure audio delays.
HS 2000 System Adm inistrator’s Handbook
Note:
If you want to return th e delays to the factory
default values, click the Reset button.
5
If you are setting up your system for the first time, click
the Next button to continue configuring the system.
Setting preferences for auto configuration settings
Even if auto c onfigu rati on is e nable d, you ca n spec ify whi ch au dio, vide o,
and communications algor ithms you want the HS 2000 system to use. The
HS 2000 system will always try to use the settings you speci fy, and will
use the default auto configuration settings only if your settings
do not work.
For example, with a line rate of 112, the system typically selects an audio
rate of G.728 to improve the video quality. However, you can change the
audio setting to G.722 to provide the highest quality audio.
38Setting preferences for auto configuration settings
HS 2000 System Adm inistrator’s Handbook
1
Select the Auto C onfi g tab from the Configuration window.
Chapter 2. Configuring AppsView
2
Select the Cut-off Line Rate.
3
Select your preferences from the Cut-Off and Below drop-down
lists.
4
Select your preferences from the Above Cut-Off drop-down lists.
Note:
T o return the delays to the factory default
values, click the Reset button.
5
If you are setting up your system for the first time, click the Next
button to continue confi guring the system.
Setting preferences for auto configuration settings39
Chapter 2. Configuring AppsView
Configuring pointing device settings
Select the Pointing Devices tab from the Configu ration window.
HS 2000 System Adm inistrator’s Handbook
1
2
3
40Configuring pointing device settings
Click the VTEL CommandTouch box to select it.
Click the No Tablet box.
If you are setting up your system for the first time, click the
Next button to continue configuring the system.
HS 2000 System Adm inistrator’s Handbook
Completing system configuration
Viewing system configuration settings
From the Configuration window, click the Finish tab.
Chapter 2. Configuring AppsView
Completing system configuration41
The Finish window shows your system’s current configuration.
Chapter 2. Configuring AppsView
Saving configuration settings
In the Finish window, click the OK button to save the configuration.
HS 2000 System Adm inistrator’s Handbook
Notes:
If the system is currently in a call when you click the
OK button, the new configuration is not saved until
after the call is co mp let ed.
T o exit without saving changes, click Cancel.
Next, configure other AppsView se ttings as described in
Chapter 3, “Prep ar ing fo r Videoconfer en ces. ”
42Completing system configuration
Preparing for
Videoconferences
This chapter explains how to set up the system so users will be able
to easily communicate with remote sites and use all the AppsV ie w
videocon fere n ci ng fea t ures .
3
43
Chapter 3. Preparing for Videoconferences
Setting up AppsView display options
This section explains how to use the options av ailable in the Advanced
Interface Setup window to configure settings that affec t the app earance of
the video image on your monitors and that enable or disable certain
AppsV iew functions.
Accessing the Advanced Inter face Setup window
1
Click the AppsVie w ic on to display the AppsView toolbar.
2
Click the System Tools button on the AppsView toolbar to display
the System Tools toolbar.
3
On the System T ools toolbar, click the Set Configuration button.
The Advanced Interface Setup window opens:
HS 2000 System Adm inistrator’s Handbook
44Setting up AppsView display options
HS 2000 System Adm inistrator’s Handbook
g
g
g
g
g
g
g
Setting display options
From the Advanced Interface Setup window, se lect the Appearance tab.
The
Launch Advanced
Config Program
displays tabs for initial
system setup and for
setting communications
profiles. See Chapter 2,
“Configuri ng AppsView.”
button
The following table describe s the options available from the Appeara nce
window:
OptionDescription
urable ToolbarsSelect this option if you want to be able
Confi
Quick HelpSelect this optio n to tu rn on Tool Ti ps.
Chapter 3. Preparing for Videoconferences
to customize AppsView toolbars by
addin
, moving, or removing buttons.
This causes a pop-up t o displa y the name
of the tool bar but ton when t he curso r is on
the button.
Toolbar TimeoutThe number of seconds AppsView
toolbars stay on the screen after you
move the cursor off the toolbar.
Display Preset ToolbarSelect this option to show the camera
preset toolba r as one of the rotations of
the AppsView toolbar.
Launch Advanced Confi
Pro
ram
Starts up the confi
for settin
Chapter 2, “Confi
system configuration. See
uration program used
uring AppsView.”
Setting up AppsView display options45
Chapter 3. Preparing for Videoconferences
Showing or hiding the Call Status window
To show the Call Status window:
1
Click the System Tools button on the AppsView toolbar
to display the configuration toolbar.
2
On the configur ation toolbar, click the Call Status button.
To hide the Call Status window:
Click the Hide button on the Call Status window.
HS 2000 System Adm inistrator’s Handbook
46Setting up AppsView display options
HS 2000 System Adm inistrator’s Handbook
Chapter 3. Preparing for Videoconferences
Setting up icons to launch applications from the AppsView toolba r
This section explains how to set up an icon so use rs can launch a
Windows 95 application from the AppsV iew toolbar:
■First, add the application’s ic on to the AppsVi ew Launch window.
■Then add the application’s icon to an AppsView toolbar.
Adding an application icon to the Launch window
1
Open the Advanced Interface Setup window. (See “Accessing the
Advanced Interface Setup window” on page 44.)
2
Select the Launch tab:
Setting up icons to launch applications from the AppsView toolbar47
Chapter 3. Preparing for Videoconferences
HS 2000 System Adm inistrator’s Handbook
You cannot drag
shortcut icons to the
Launch window.
3
Drag the application icon you want from W indows Explorer
to the blank area in the Launch tab.
For example, to add an Excel
■Click the Windows Start button, then select Run.
■Enter the path for the Excel application (or use Browse
™
icon:
to locate it).
■Select the Excel applica tion.
■Hold down the right mouse button and drag the application icon
to the Launch tab.
Adding an application icon to the AppsView toolbar
After you add t he applic ation to the La unch window, add the application ’s
icon to the AppsView toolbar:
1
Display the AppsView toolbar to which you want to add the
application button.
2
Place the cursor on the bor der of the toolba r and clic k the right mou se
button.
48Setting up icons to launch applications from the AppsView toolbar
HS 2000 System Adm inistrator’s Handbook
The Modify Toolbars window opens:
3
Scroll through t he icons until you see the icon for the application you
want, select that icon, dr ag it to the AppsView toolbar, and drop it
there.
Chapter 3. Preparing for Videoconferences
Deleting a button from the AppsView toolbar
1
Display the toolbar conta ining the button you want to delete.
2
Use a right mouse button click to se lect the butt on you want to delete,
then drag the button away from the toolbar.
Removing an application icon
From the Launch tab of the Advanced Interface Setup window, select the
icon you want to remove, the n click the Remove button.
Setting up icons to launch applications from the AppsView toolbar49
Chapter 3. Preparing for Videoconferences
HS 2000 System Adm inistrator’s Handbook
Specifying a folder for incoming file transfers
This section explains how to specify the folder for incoming files from
remote sites.
By default, tr ansferred files will be placed in this folder: c:\vtel\files.
If you want to change the location:
1
Open the Advanced Interface Setup window. (See “Accessing the
Advanced Interface Setup window” on page 44.)
2
Select the File Locations tab:
3
50Specifying a folder for incoming file transfers
Enter the path for the folder in which you want incoming files
to be located, then click OK.
HS 2000 System Adm inistrator’s Handbook
Chapter 3. Preparing for Videoconferences
Specifying a fold er for PenPal slide trays
By default, PenPal slide trays are located in the c:\vtel\slides folder.
If you want to change the PenPal slide location:
1
Open the Advanced Interface Setup window. (See “Accessing the
Advanced Interface Setup window” on page 44.)
2
Select the File Locations tab:
Specifying a folder for PenPal slide trays51
3
Select the folder in which you want your slide trays to be located,
then click OK.
Chapter 3. Preparing for Videoconferences
Designating the document camera
HS 2000 System Adm inistrator’s Handbook
Your HS 2000
system must ha ve
more than one
camera in order for
you to be able to use
the document
camera feature.
The document camera feature lets PenPal for Windows users captur e
and send slides by simply pressing the Send Sl ide button After t he slid e is
sent, control is automatically switched back to the local camera.
Send Slide
button
To designate one or more loc al cameras as the video source for the
document camera (typically camera 3):
1
Open the Advanced Interface Setup window. (See “Accessing the
Advanced Interface Setup window” on page 44.)
2
Select the Document Camera tab.
The Document Camera window opens:
52Designating the document camera
HS 2000 System Adm inistrator’s Handbook
3
Check the box fo r each camera that you wish to use as a
documen t camera.
Chapter 3. Preparing for Videoconferences
Notes:
Although the documen t camera is typically assigned to
the document stand camera, the camera you select does
not have to be the document stand camera; it can be
any motion camera (except a VCR).
If you do not select a camera from the Document
window , the document camera featur e is disabled.
If your HS 2000 system has the SmartView option
installed and enabled, the document c amera feature is
disabled for Camera 3.
T o disable and re-enable SmartView, press the
SmartView button on the AppsView toolbar.
The button is gray when SmartView is disabled.
Designating the document camera53
Chapter 3. Preparing for Videoconferences
Setting up Address Book entries
You can set up entries for videoconferencing sites in the Address Book
to make it easy for users to call those sites.
Accessing the Address Book
To access the Address Book, press the Call button, then select the
Address Book tab.
HS 2000 System Adm inistrator’s Handbook
54Setting up Address Book entries
HS 2000 System Adm inistrator’s Handbook
Entering a new site in the Address Book
1
Click the New button.
2
Enter the name of the site in the Name field.
3
Select a line speed.
4
Use the keyboard to enter the site’s number in the Port A field (and
the Port B field, if nec es sary ).
5
Select the communicatio ns profile to use:
■If you want to use the default profile, select Use Default profile.
(The default profile is the profile displayed in the Default Profile
field in the Communications window. See page 25.)
Chapter 3. Preparing for Videoconferences
■If you want to use a profile other than the default profile, select
Always use, then select the profile name in the drop-down list.
6
Click Save to save the new entry.
The site name is now listed in the Address Book and in the
Speed-Dialer List.
Dialing a site from the Address Book
1
Highlight the site’s name in the list.
2
Click Dial.
Setting up Address Book entries55
Chapter 3. Preparing for Videoconferences
Deleting a site from the Address Book
1
Highlight the site’s name in the list.
2
Click Delete.
Setting up Speed-Dialer site buttons
This section explains how to set up Speed-Dialer site buttons so users
can dial frequently-called sites by clicking a single button.
After you set up a site in the Address Book, that site name appe ars
in the Speed-Dialer window:
HS 2000 System Adm inistrator’s Handbook
Drag the name of the site from the list to a site button.
56Setting up Speed-Dialer site buttons
HS 2000 System Adm inistrator’s Handbook
Setting camera preset positions
When you first set up the HS 2000 system, you may want to set camera
positions for local or remote camera s, which users will be able to select
from the presets toolbars.
Setting a camera preset for a local camera
T o set a local camera preset position:
1
Select a local camera you’ll use for sending video to the remote sit e.
(The HS 2000 Installation and User’s Handbook contains informat ion
about how to select a camera.)
2
Use the AppsV iew on-screen cursors to adjust camera settings
(or use the Zoom, Iris, and camera movement buttons on the touch
panel). (You must f ocus a document stand camera manually.)
Chapter 3. Preparing for Videoconferences
3
Click the Rotate Toolbars button to display the Local Camera
Presets toolbar.
Group View
preset button
preset buttons
(A - E)
Setting camera preset positions57
display Remot e
Presets toolbar
save a camera
preset posit ion
Chapter 3. Preparing for Videoconferences
4
Click the Store button on the Local Camera Presets toolbar.
5
Click one of the preset buttons on the Local Camera Presets toolbar
(or on the touch panel).
If you wish, set additional pres et positions for this camera or for other
cameras by repeating steps 1 thr ough 4. (Remember to select a different
preset button for each preset.)
Setting a cam era preset for a remote camera
HS 2000 System Adm inistrator’s Handbook
You cannot set
remote came ra
presets if the remote
site does not support
remote came ra
control.
A document stand
camera must be
adjusted manuall y.
To set a remote cam era pre se t:
1
Establish a videoconfe renc e call with the remote site.
2
Select a remote camera. (The HS 2000 Installation and User’s
Handbook tells how to select a c amera.)
3
If the camera is a PTZ (pan/tilt/zoom) camera, use the AppsView
on-screen cursors to adjust camera settings (or use the Zoom, Iris,
and camera m ove me nt b uttons on the touch panel).
4
Select the Rota te Toolbars button to display the Local Camera
Presets toolbar, the n click the Remote button to display the Remote
Camera Presets toolbar.
5
Click the Store button on the Remote Camera Presets toolbar.
58Setting camera preset positions
HS 2000 System Adm inistrator’s Handbook
6
Click one of the remote preset buttons on the Remote Camera Presets
toolbar (or press one of the Remote Camera Preset buttons on the
touch panel.)
If you wish, set additional pres et positions for this camera or for other
cameras by repeating steps 3 thr ough 5. (Remember to select a different
preset button for each preset.)
Fine- tuning audio and video settings
This section expla ins how to us e t he AppsView Control Panel to fine-tune
the system’s audio and video.
Accessing the Control Panel
Chapter 3. Preparing for Videoconferences
1
Click the System Tools button on the AppsView toolbar to display
the configuration toolbar.
2
Click the Control Panel button on the configuration toolbar.
The Control Panel window opens.
Fine-tuning audio and video settings59
Chapter 3. Preparing for Videoconferences
g
g
Fine-tuning audio settings
The Control Panel’s Audio tab lets you set audio levels:
HS 2000 System Adm inistrator’s Handbook
Changing the audio level
Move the control button on the vertical slide bars to increase or decrease
volume levels as shown in the following table.
SettingDescription
Speaker V olumeAudio level of the speaker at the local site.
VCR Play VolumeAudio level of the sound from the VCR
oing to the expansion uni t’s VCR In port.
VCR Record LevelAudio level of the sound
the VCR Out port of the expansion box
to the VCR.
60Fine-tuning audio and video settings
oing from
HS 2000 System Adm inistrator’s Handbook
Chapter 3. Preparing for Videoconferences
Note:
You can also control the audio level by moving the
volume control slider over the AppsView icon.
Setting audio delay (adjusting lip sync)
During a call, if mouth movements are not in sync with the words the
speaker is saying, the lip sy nc is not correct.
The HS 2000 system provides audio delay of incoming speech in order to
synchronize with the vide o, be cause the video compression process
requires additiona l time. The compression time varies, depending on the
data rate and the amount o f motion. Audi o dela y is p reset t o the be st value
for each line rate. In unusual circumstances, you may need to adjust the
audio delay.
The Rx (receive) and Tx (transmit) fields indicate the data reception and
transmission rates in millisec onds.
Add 40 milliseconds to the Receive fi eld by moving the button on the
vertical slide bar. Continue to add to the Rx field in 40-millise cond
increments until lip sync is correct.
T o help a system administrator at a remote site adjust lip sync, change the
rate in the Tx field.
Fine-tuning audio and video settings61
Chapter 3. Preparing for Videoconferences
Fine-tuning video settings
To adjust vide o settings, select the Video tab from the Control Panel:
HS 2000 System Adm inistrator’s Handbook
Quality balance
Adjust the quality of the video by moving the slide r to attain the best
balance between a higher (faster) frame rate and greater image clarity.
62Fine-tuning audio and video settings
HS 2000 System Adm inistrator’s Handbook
Chroma-key color
Chapter 3. Preparing for Videoconferences
The default
chroma-key color
is magenta.
The chroma-key color you select determines the PC VGA color that is
replaced by live video on your HS 2000 system screens.
If you see video showing through other applications, those applications
are using the same chroma key that AppsView is using. Select a different
AppsV iew chroma-key color, one that is not likely to be common in the
applications you run.
If you do want to change the chroma-key color, click the Palette button
and select a color from the palette, or move the Red, Green, and Blue
slider bars to create your own color.
Customizing AppsView toolbars
This section describes how to customize the AppsView toolbars.
Note:
Before you can customize toolbars, the Configurable
Toolbars option must be selected in the Advanc ed
Interface Setup window. See “Setting display options”
on page 45.
Customizing AppsView toolbars63
Specifying toolbar timeout length
To specify how long AppsView toolba rs remain visible after they are
selected, use the Toolbar Timeout option on the Appearance tab of the
Advanced Interface Setup, as describ ed on p ag e 45.
Chapter 3. Preparing for Videoconferences
Adding a function button to a toolbar
HS 2000 System Adm inistrator’s Handbook
To add a button for
launching a Wi ndows
95 application from
the toolbar, see
“Setting up icons to
launch applications
from the AppsView
toolbar” on page 47.
1
Display the toolbar to which you want to add a function.
2
Place the cursor on the border of the toolbar an d click the
right mouse button.
The Modify Toolbars window opens:
border
3
64Customizing AppsView toolbars
Select the icon for the function you need, then drag it to the toolbar.
HS 2000 System Adm inistrator’s Handbook
Adding a Windows application button to a toolbar
You can add buttons for Windows applications to the AppsView toolbar
so that users can launch applications by selecting them from the toolbar.
See “Setting up icons to launch applications from the AppsView toolbar”
on page 47.
Deleting a button
1
Display the toolbar conta ining the button you want to delete.
2
Use a right mouse button click to se lect the butt on you want to delete,
then drag the button away from the toolbar.
Removing and restoring an AppsView toolbar
Chapter 3. Preparing for Videoconferences
You may find that your site does not need one of the AppsView toolbars.
This section explains how to remove and rest ore a tool bar.
Note:
You cannot remove all the AppsView toolbars.
One toolbar must always be available.
Removing and restoring camera presets toolbar
To remove a c amera presets toolbar:
1
Display the Appearance window of the Advanced Interface Setup
program. (See “Accessing the Advanced Interface Setup window” on
page 44.)
2
De-select the Display Preset Toolbar check box.
Customizing AppsView toolbars65
Chapter 3. Preparing for Videoconferences
To restore a camera presets toolb ar:
1
Display the Appearance window of the Advanced Interface Setup
program. (See “Accessing the Advanced Interface Setup window” on
page 44.)
2
Check the Display Prese t Toolbar check box.
Removing and restoring other AppsView toolbars
1
Display the toolbar you want to remove.
2
Hold down the right mouse button while you drag the Rotate
Toolbars button off the toolbar.
When you press the Rotate Toolbars button on the remaining toolbars,
the toolbar you removed no longer appears.
HS 2000 System Adm inistrator’s Handbook
To restore a toolbar you remove (other tha n a camera presets toolbar),
rebuild a new toolbar by following the instructions in “Adding an
AppsV iew toolbar” on page 67.
66Customizing AppsView toolbars
HS 2000 System Adm inistrator’s Handbook
Adding an AppsView toolbar
T o add a toolbar to the AppsView toolbar rotation:
1
Display any AppsView toolbar.
2
Place the cursor on the bor der of the toolba r and clic k the right mou se
button. The Modify Toolbars window opens:
Chapter 3. Preparing for Videoconferences
3
Click the New button.
4
Enter a name for your new toolbar. A new Rotate Toolbars button
appears.
5
Select an icon from the icons displayed in the Modify Toolbars
window. Hold down the left mouse button and drag the icon to
the new Rotate Toolbars button. Repeat this step for each icon
you want to appear on your new toolbar.
Note:
The icons do not appear as buttons on the new
toolbar until you click the Close button.
Customizing AppsView toolbars67
Chapter 3. Preparing for Videoconferences
6
Click the Rotate Toolbars button on the new toolbar to change the
orientation of the toolbar to a hor izontal position.
7
Place the cursor on the border of the new toolbar and hold down the
left mouse button while you drag the new toolbar to the AppsView
icon in the lower right corner of the screen.
When you click the Rotate Toolbars button, your new toolbar now
appears in the rotation cycle .
HS 2000 System Adm inistrator’s Handbook
68Customizing AppsView toolbars
Monitoring
System Operation
This chapter describes how to use the VTEL System Monitor application
to check the current status of various HS 2000 system operations.
Accessing System Monitor windows
1
Click the AppsVie w ic on to display the AppsView toolbar.
2
Click the System Tools button on the AppsView toolbar to display
the System Tools toolbar.
3
On the System T ools toolbar, click the Sys tem Monitor button.
The System Monitor window opens.
4
Accessing Syste m Monit or windows69
Chapter 4. Monitoring System Operation
HS 2000 System Adm inistrator’s Handbook
4
Click the appropriate button on the right side of the System Monitor
window to display the type of system information you need. For
example, to vie w the Error Log, click the Error Log button.
70Acce ssing System Monitor windows
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.