USER MANUAL
DT607C-V1 / 201608
• Please read this manual carefully to ensure safe and correct operation
• Keep this manual for future reference
DT607C-S1 DT607C-S2
MODEL DT607C
2-WIRE SERIES

CONTENTS
PARTS AND FUNCTIONS
Parts Names 1
Mounting 1
External Motion Detection 2
SETUP INSTRUCTIONS 3
Functions Setting Up 3
Setting Door Station Address 4
Setting Door Station Calling Mode 4
Setting Unlock Mode 6
Setting Unlock Time 6
Setting Nameplate Illumination Mode 7
Setting Night View LED Illumination Mode 7
Setting Ring Tone 8
WIRING 9
Connecting Electric Lock 9
Connecting 1-Monitor Kit 10
Connecting Multiple Door Stations 10
Connecting Multiple Monitors 11
APPENDIX 13
Precautions 13
Specications 13
Cable Requirments 14

-1-
Parts Names
PARTS AND FUNCTIONS
[11]
[10]
[9]
[1]
[3]
[4]
[8]
[7]
[6]
[5]
[12]
[13]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Front panel
[7] Speaker
[8] Night view LED
[9] Camera lens
[10] Rain cover
[11] Mounting hook
[12] Connection port
[13] Screw hole
Mounting
1 2 3 4 5
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Rain cover
Rainy cover
The distance between
the top of main unit
and rain cover should
be not less than 3mm.
Main unit
Main unit
≥3mm
1. Connect the cable
2. Drill holes in the wall to match the size of screw stoppers,then attach the rain cover and
main unit to the wall. Distance between the top of main unit and rain cover should be not less
than 3mm
3. Install the name plate
4. Attach the front cover to the main unit
5. Use supplied allen key and the screws to x the cover
The installation height is suggested to 145~160cm

-2-
PARTS AND FUNCTIONS
Terminals description
Lock Control Jumper:
To set lock type
Motion Detector Connection Port:
To connect external PIR motion
detector
Main Connection Port:
To connect the bus line and the electric lock
• L1,L2: Connect bus line, no-polarity
• PL: External lock power input, connect to the power positive (power +).
• S+: Lock power(+) output
• S-: Lock power(-) output, connect to the power(-) input of lock(only when lock is powered
from the Door Station)
1 2 3
Lock Control Jumper
PIR Motion Detector
Connection Port
+12V
GND
PIR
L1
L2
PL
S+
S-
Main Connection Port
External Motion Detection
The door station is equipped with a terminal to
connect external motion detector sensor
If the external motion detector is connected to
the system and it detect someone passing by, it
will turn on security light. Additional DT-RLC is
required
12V
Motion

-3-
SETUP INSTRUCTIONS
Functions Setting Up
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_TALK
LED_NAME
This section explains the settings of each
function. Please refer to the following table.
To perform the settings for the function
you want, you should remove door station
cover plate
Each operation is indicated by the lighting
up of the LED indicator on the unit and by
the sounding of the buzzer.
Order Setting items Setting range Default value
1 Setting door station address 0~3 0
2
Setting door station
calling mode
Standard/Group calling mode Standard calling mode
3 Setting the unlock mode 0:opened/1:closed 0:opened
4 Setting the unlock time 01 to 99 seconds 1 seconds
5
Setting the nameplate
illumination mode
On/Off/Auto On
6
Setting night view LED
illumination mode
On/Off/Auto Auto
7 Setting ring-back tone
Ringing ones
Ring continuously
No ring-back tone
Ringing ones