V-Tec DT607, DT607ID, DT607A, DT607ID-S4, DT607FE-S3 User Manual

...
USER MANUAL
DT-ENG-DT607-V1 / 201607
• Please read this manual carefully to ensure safe and correct operation.
• Keep this manual well for future reference.
RF CARD
RF CARD
RF CARD
RF CARD
RF CARD
RF CARD
DT607A/ID-S4DT607/ID/FE-S1 DT607/ID/FE-S2
DT607F/ID/FE-S4DT607/ID/FE-S3 DT607/ID/FE-S4
2 WIRE SYSTEM
Fisheye door station with proximity access control
CONTENTS
PARTS AND FUNCTIONS ..................................................................................... 3
Part Names............................................................................................................. 3
Mounting ................................................................................................................. 4
BASIC FUNCTIONS .............................................................................................. 6
Unlock Operations .................................................................................................. 6
Fisheye Camera ..................................................................................................... 6
External Motion Detection ...................................................................................... 6
SETUP INSTRUCTIONS ........................................................................................ 7
Functions Setting Up .............................................................................................. 7
Setting Door Station Address .................................................................................8
Setting Door Station Calling Mode ......................................................................... 8
Setting Camera Resolution.................................................................................... 10
Setting Unlock Mode ............................................................................................. 10
Setting Unlock Time............................................................................................... 11
Setting Nameplate Illumination Mode .................................................................... 11
Setting Night View LED Illumination Mode ............................................................ 12
Setting Ring-back Tone ......................................................................................... 12
Setting Image Display Mode.................................................................................. 13
Registering ID Card ............................................................................................... 14
WIRING ................................................................................................................. 17
Connecting Electric Lock ....................................................................................... 17
Connecting Basic One-to-one ............................................................................... 18
Connecting Multi Door Stations ............................................................................. 18
Connecting Multi Monitors ..................................................................................... 19
APPENDIX ............................................................................................................ 21
Precautions............................................................................................................ 21
Specication .......................................................................................................... 21
Cables and Requirments ....................................................................................... 22
-3-
Part Names
PARTS AND FUNCTIONS
[11]
[10]
[14]
[9]
[1]
[3]
[4]
[1]
[3]
[4]
[8]
[7]
[6]
[5]
[9]
[8]
[7]
[6]
[5]
[12]
[11]
[12]
[13]
[13]
[2]
[2]
Surface mounted
Flush mounted
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Front panel
[7] Speaker
[8] Night view LED
[9] Camera lens
[10] Rainy cover
[11] Mounting hook
[12] Connection port
[13] Screw hole
[14] Mounting box
-4-
PARTS AND FUNCTIONS
Mounting
1 2 3 4 5
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Rainy cover
Rainy cover
The distance between the top of main unit and rain cover should be not less than 3mm.
Main unit
Main unit
≥3mm
1 2 3 4 5
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
1. Connect the cable correctly.
2. Drill holes in the wall to match the size of screw stoppers,then attach the rainy cover and main unit to the wall, and the distance between the top of main unit and rain cover should be not less than 3mm.
3. Install the name plate.
4. Attach the front panel to the main unit.
5. Use the special screwdriver and the screws to x the panel.
1. Drill a hole in the wall to match the size of mounting box,then attach the mounting box to the wall.
2. Loosen the high screws to install the name plate.
3. Connect the cable correctly.
4. Attach the front panel to the mounting box,then use the special screwdriver and the screws to
x the panel.
5. Finish the installation.
Surface mounted
Flush mounted
The installation height is suggested to 145~160cm.
* The camera angle view of surface mount model may be less than 1700.
-5-
PARTS AND FUNCTIONS
Terminal description
Lock Control Jumper:
To select the lock type.
Motion Detector Connect Port:
To connect external PIR motion detector.
Main Connect Port:
To connect the bus line and the electronic locks.
L1,L2: Connect to the bus line, no polarity.
PL: External lock power input, connect to the power positive(power +).
S+: Lock power(+) output.
S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door
station to power the locks, if using the external power supply for the locks, the S- will not be connected).
1 2 3
Lock Control Jumper
PIR Motion Detector Connect Port
+12V
GND
PIR
L1
L2
PL
S+
S-
Main Connect Port
-6-
BASIC FUNCTIONS
Unlock Operations
Unlocking of ID Card
When the registered user card has been shown to ID card window, the UNLOCK indicator lights
up, the buzzer sounds,and the electric door strike is unlocked.
If show the authorized user card,the buzzer will sound of beep+,and the UNLOCK indicator will light up.
If show the unauthorized user card,the buzzer will sound of beep,beep,beep.
Fisheye Camera
External Motion Detection
Please note that this function requires the
monitor with sheye function to support.
The angle view is 170
0
,visitors in this angle
view can be seen clearly and can be zoomed
to see individuals up close via indoor monitor
with sheye function.
The door station is equipped with a terminal to
connect external motion detector.
If the external motion detector is connected
to the system,following functions will be effec-
tive:
If detect someone passing by, the door station
can be activated operation to unlock or turn
on light.
Standard
door station angle
DT607
1700 door camera angle
(Wide angle view shown)
12V
Motion
detector
GND
PIR
* Please contact with supplier for more details about detector connection.
-7-
SETUP INSTRUCTIONS
Functions Setting Up
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_TALK
LED_NAME
RF CARD
This section explains the settings of each
function,please refer to the following table:
To perform the settings for the function
you want,you should move away the metal
front panel. Please refer to the sketch
map.
Each operation is indicated by the lighting
up of the LED indicator on the unit, and by
the sounding of the buzzer.
Order Setting items Setting range Default value
1 Setting door station address 0~3 0
2
Setting door station
calling mode
Standard/Group calling mode Standard calling mode
3 Setting camera resolution High/Low High
4 Setting the unlock mode 0:opened/1:closed 0:opened
5 Setting the unlock time 01 to 99 seconds 1 seconds
6
Setting the nameplate
illumination mode
On/Off/Auto On
7
Setting night view LED
illumination mode
On/Off/Auto Auto
8 Setting ring-back tone
Ringing one time
Ring continuously
No ring-back tone
Ringing one time
9 Setting image display mode
Alternate switching mode
Zoom mode
Full screen mode
Alternate switching mode
-8-
Setting Door Station Address
Setting Door Station Calling Mode
Total 4 addresses can be congured. It can be modied either before or after installation.
0 is default, to change the setting, please follow the steps:
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep+, Beep
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep+
In standby mode, press KEY_SET button once
Press KEY_1 button to set the first door station.
Press KEY_2 button to set the second door station.
Press KEY_3 button to set the third door station.
Press KEY_4 button to set the fourth door station.
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep,Beep
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep,Beep,Beep
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep,Beep,Beep,Beep
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
SETUP INSTRUCTIONS
If setting mode has not been exited, you can change the address of door station by pressing KEY1~4 freely.
The LED_NAME indicator will always blink until exit out the setting mode.
If without any operation in 10 seconds, it will exit out setting mode automatically.
In this step,press KEY_SET button four times to exit out the setting mode manually.
There are two calling modes for door station,Standard calling mode and Group calling mode.
Please know that the door station work in Standard calling mode by default.
-9-
If setting mode has not been exited, you can change the calling mode by pressing KEY1 circularly.
The LED_NAME indicator will blink all the time until exit out the setting mode.
If without any operation in 10 seconds, it will exit out setting mode automatically.
In this step,press KEY_SET button three times to exit out the setting mode manually.
SETUP INSTRUCTIONS
* More details about code setting for monitor, please refer to corresponding user manual .
Each call button will respond different addresses when set in different calling mode. Refer to the
followings for more informations.
Call buttonA: call the monitor with address 01 by default.
Call buttonB: call the monitor with address 02 by default.
Call buttonC: call the monitor with address 03 by default.
Call buttonD: call the monitor with address 04 by default.
Call buttonA: Call all monitors in group address from
00~15.(one of the monitor should be set to 00)
Call buttonB,C,D: Call all monitors in group address from
16~31. (one of the monitor should be set to 16)
UNLOCK Indicator:OFF TALK Indicator:ON
Buzzer
Beep+, Beep
In standby mode, press KEY_SET button twice.
UNLOCK Indicator:OFF TALK Indicator:ON
Buzzer
Beep+
Press KEY_1 button to activate Standard calling mode for door station.
UNLOCK Indicator:OFF TALK Indicator:ON
Buzzer
Beep, Beep
Press KEY_1 button again to activate Group calling mode for door station.
Press KEY_1
A
B
C
A
B
C
D
RF CARDRF CARD
A A
B
RF CARDRF CARD
1.Standard calling mode(Address range 01-04
by default)
2.Group calling mode
To change this setting, please follow the steps:
-10-
Setting Camera Resolution
Setting Unlock Mode
The resolution of the camera can be adjusted at any time, that means the quality of image on
screen can be set to high or low.
High resolution is default, to change the setting, please follow the steps:
There are 2 unlock modes, Normally opened and Normally closed.
Normally opened is default, to change the setting, please follow the steps:
UNLOCK Indicator:OFF TALK Indicator:ON
Buzzer
Beep+, Beep
In standby mode, press KEY_SET button twice.
UNLOCK Indicator:OFF TALK Indicator:ON
Buzzer
Beep+
Press KEY_2 button to set the camera to High resolution.
UNLOCK Indicator:OFF TALK Indicator:ON
Buzzer
Beep, Beep
Press KEY_2 button again to set the camera to Low resolution.
Press KEY_2
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button three times.
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep+
Press KEY_1 button to set the unlock mode to Normally opened.
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep, Beep
Press KEY_1 button again to set the unlock mode to Normally closed.
Press KEY_1
SETUP INSTRUCTIONS
If setting mode has not been exited, you can change the camera resolution by pressing KEY2 circularly.
The LED_NAME indicator will blink all the time until exit out the setting mode.
If without any operation in 10 seconds, it will exit out setting mode automatically.
In this step,press KEY_SET button three times to exit out the setting mode manually.
If setting mode has not been exited, you can change the unlock mode by pressing KEY1 circularly.
The LED_NAME indicator will blink all the time until exit out the setting mode.
If without any operation in 10 seconds, it will exit out setting mode automatically.
In this step,press KEY_SET button twice to exit out the setting mode manually.
-11-
Setting Nameplate Illumination Mode
Setting Unlock Time
There are 3 illumination modes for nameplate indicator, Normally on,Normally off and Auto.
Normally on is default, to change the setting, please follow the steps:
By default, the unlock time is 1s, but it can be changed,the setting range is 1s~99s.
Follow the steps:
SETUP INSTRUCTIONS
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button three times.
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep,Beep......
Press and hold on KEY_2 button. The time you holding on is the new unlock time.
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button three times.
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep+
Press KEY_3 button to set the nameplate illumination mode to Normally on.
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep, Beep
Press KEY_3 button again to set the nameplate illumina­tion mode to Normally off.
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep, Beep,Beep
Press KEY_3 button again and again to set the nameplate illumination mode to Auto.
Press KEY_3
When entering time delayed setting, the buzzer sound one time every second.
The LED_NAME indicator will blink all the time until exit out the setting mode.
If without any operation in 10 seconds, it will exit out setting mode automatically.
In this step,press KEY_SET button twice to exit out the setting mode manually.
If setting mode has not been exited, you can change the nameplate illumination mode by pressing KEY3
circularly.
The LED_NAME indicator will blink all the time until exit out the setting mode.
If without any operation in 10 seconds, it will exit out setting mode automatically.
In this step,press KEY_SET button twice to exit out the setting mode manually.
-12-
Setting Ring-back Tone
If allow ring-back tone, press the call button to call monitor, a ring-back call tone can be heard
from door station.
There are 3 ring-back call tones, Ringing one time,Ringing continuously and No ring-back
tone.
Ringing one time is default, to change the setting, please follow the steps:
Setting Night View LED Illumination Mode
There are 3 working modes for night view LED indicator, Normally on,Normally off and Auto.
Auto is default, to change the setting, please follow the steps:
SETUP INSTRUCTIONS
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button three times.
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep+
Press KEY_4 button to set the night view LED mode to Normally on.
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep, Beep
Press KEY_4 button again to set the night view LED mode to Normally off.
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep, Beep,Beep
Press KEY_4 button again and again to set the night view LED mode to Auto.
Press KEY_4
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button four times.
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep+
Press KEY_1 button to set the ring-back call tone ringing one time.
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep, Beep
Press KEY_1 button again to set the ring-back call tone ringing continuously.
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep, Beep,Beep
Press KEY_1 button again and again to close ring-back call tone.
Press KEY_1
If setting mode has not been exited, you can change the night view LED illumination mode by pressing
KEY4 circularly.
The LED_NAME indicator will blink all the time until exit out the setting mode.
If without any operation in 10 seconds, it will exit out setting mode automatically.
In this step,press KEY_SET button twice to exit out the setting mode manually.
If setting mode has not been exited, you can change the ring-back tone by pressing KEY1 circularly.
The LED_NAME indicator will blink all the time until exit out the setting mode.
If without any operation in 10 seconds, it will exit out setting mode automatically.
In this step,press KEY_SET button once to exit out the setting mode manually.
-13-
Setting Image Display Mode
Please know that this setting is only effective for monitors which does not support man-
ual operation for pan-tilt.
When door station calls monitor,the image will be displayed on screen,there are 3 modes for im-
age displayed, Alternate switching mode,Zoom mode and Full screen mode.
Alternate switching mode: when the monitor being called, switch at regular time(5s) between
Full screen and Zoom image.
Zoom mode: when the monitor being called, the image will be displayed on full screen for 5
seconds, then switch to Zoom image.
Full screen mode: when the monitor being called, the image will be always displayed on Full
screen.
Alternate switching mode is default, to change the setting, please follow the steps:
When answering the call, the image switching reminder can be activated or forbidden.
If set to activated mode, the image switching reminder will be different for different image display
mode.
Alternate switching mode: When answering the call, image switching reminder is not effective.
Zoom mode: When answering the call, the image will be displayed on full screen for 5 sec-
onds, then switch to Zoom image to remind to enter talking status.
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button four times.
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep+
Press KEY_2 button to set the image display mode to Cycle switching.
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep, Beep
Press KEY_2 button again to set the image display mode to Zoom mode.
UNLOCK Indicator:ON TALK Indicator:ON
Press KEY_2
Buzzer
Beep, Beep,Beep
Press KEY_2 button again and again to set the image display mode to Full screen.
SETUP INSTRUCTIONS
When the monitor being called
When answering the call
If setting mode has not been exited, you can change the image display mode by pressing KEY2 circularly.
The LED_NAME indicator will blink all the time until exit out the setting mode.
If without any operation in 10 seconds, it will exit out setting mode automatically.
In this step,press KEY_SET button once to exit out the setting mode manually.
-14-
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button four times.
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep+
Press KEY_3 button to activate image switching when answering the call.
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep, Beep
Press KEY_3 button again to forbid image switching when answering the call.
Press KEY_3
Registering ID Card
Up to 320 user cards can be registered by the door station.
Easy management with LED status and sound hints.
There are two master cards, one MASTER CARD ADD card
and one MASTER CARD DELETE card, When registered new master cards, the old master cards are invalid automatically.
Card reading distance is less than 3cm.
The master cards are necessary when you add or delete user
cards. Please keep it well for future use.
EM card, 125kHz.
Authorizing master cards:
By default,there are two master cards marked MASTER CARD ADD and MASTER CARD
DELETE ,but you should know that the master card can be authorized by users at any time.
That means any two user cards can be authorized to master cards,When registered new master
cards, the old master cards will be invalid automatically.
SETUP INSTRUCTIONS
If setting mode has not been exited, you can change the image display mode by pressing KEY3 circularly.
The LED_NAME indicator will blink all the time until exit out the setting mode.
If without any operation in 10 seconds, it will exit out setting mode automatically.
In this step,press KEY_SET button once to exit out the setting mode manually.
Full screen mode: When answering the call, the image will be displayed on Zoom mode for 5
seconds, then switch to Full screen to remind to enter talking status.
If set to forbidden mode, there is no image switching reminder at any image display mode.
Activated is default, to change the setting, please follow the steps:
-15-
SETUP INSTRUCTIONS
Switching Access Control:
UNLOCK Indicator:OFF TALK Indicator:ON
Buzzer
Beep+, Beep
Show the master card of MASTER CARD ADD to ID card window in standby.
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep+, Beep
Show the master card of MASTER CARD DELETE to ID card window.
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep+
Show the master card of MASTER CARD DELETE again to switch as a door station access control.
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep+,Beep
Show the master card of MASTER CARD DELETE again to switch to DT-ACC controlled.
The access can be controlled by door station or DT-ACC,so it’s available to switch the access
function.
If without any operation in 10 seconds, it will exit out setting mode automatically.
If current access is controlled by door station, next access switching setting is controlled by DT-ACC.
UNLOCK Indicator:Blink two times TALK Indicator:OFF
Buzzer
Beep,Beep
Show the first card to ID card window, set the card of MASTER CARD ADD.
UNLOCK Indicator:Blink three times TALK Indicator:OFF
Buzzer
Beep,Beep,Beep
Show the second card to ID card window, set the card of MASTER CARD DELETE.
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep+, Beep
When power on in 10s,press and hold on KEY_SET button for 3s.
UNLOCK Indicator:Blink one time TALK Indicator:OFF
Buzzer
Beep+
Press KEY_2 button.
The LED_NAME indicator will always blink until exit out the master card authorized mode.
If without any operation in 10 seconds, it will exit out setting mode automatically.
It will exit out setting mode automatically after showing these two cards,the UNLOCK&TALK indicator will be
turned off.
-16-
Adding User Cards:
UNLOCK Indicator:OFF TALK Indicator:ON
Buzzer
Beep+, Beep
Show the master card of MASTER CARD ADD to ID card window in standby.
UNLOCK Indicator:OFF TALK Indicator:Blink one time
Buzzer
Beep+
Show user cards to be added in sequence.
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep, Beep+
Show the master card of MASTER CARD ADD again to exit.
If without any operation in 10 seconds, it will exit out setting mode automatically.
To add user card, the access must be controlled by door station.
SETUP INSTRUCTIONS
Deleting User Cards:
Initializing Access (delete all user cards):
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep+, Beep
Show the master card of MASTER CARD DELETE to ID card window in standby.
UNLOCK Indicator:Blink one time TALK Indicator:OFF
Buzzer
Beep+
Show user cards to be deleted in sequence.
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep, Beep+
Show the master card of MASTER CARD DELETE again to exit.
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep+, Beep
Show the master card of MASTER CARD DELETE to ID card window in standby.
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Beep+, Beep
UNLOCK Indicator:Blink for some time TALK Indicator:Blink for some time
Buzzer
Beep
Show the master card of MASTER CARD ADD again, format is activated.
Show the master card of MASTER CARD ADD to ID card window.
.If without any operation in 10 seconds, it will exit out setting mode automatically.
To add user card, the access must be controlled by door station.
If without any operation in 10 seconds, it will exit out setting mode automatically.
To add user card, the access must be controlled by door station.
• At step3, the UNLOCK & TALK indicator will blink all time until formatting is nished.
• When formatting is nished, UNLOCK & TALK indicator will be turned off and sound “ Beep+ ”, and exit out
setting mode automatically.
-17-
Connecting Electric Lock
Door Lock Controlled with Internal Power
Door Lock Controlled with Dry Contact
1.Electronic lock of Power-on-to-unlock
type should be used.
2.The door lock is limited to 12V, and hold-
ing current must be less than 250mA.
3.The jumper should be placed on position
2 and 3 before connecting.
4.The door lock control is not timed from
Exit Button(EB).
5.The
Unlock Mode
must be set to 0 (by
default).
1.The external power supply must be used
according to the lock.
2.The inside relay contact is restricted to
230Vac 1A or 24Vdc 1A.
3.The jumper must be taken off before
connecting.
4.Setup the
Unlock Mode
according to
different lock types.
Power-on-to-unlock type:Unlock Mode=0 (by default)
Power-off-to-unlock type:Unlock Mode=1
EB
*
LOCK
Jumper position on 2&3
1 2 3
L1 L2 PL S+ S-
Take off the jumper
1 2 3
L1 L2 PL S+ S-
LOCK
POWER SUPPLY
WIRING
* DT-RLC relay actuator is needed for 2nd lock connection.
-18-
WIRING
Max.4 door stations can be connected to the system.
Ensure to set the correct address for each door station, Refer to Page 8 for more details
about the address setting of door stations.
Connecting Basic One-to-one
Connecting Multi Door Stations
BUS(IM) BUS(DS)
-
+
L1 L2 PL S+ S-
ID=0
Code=1, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
RF CARD
PC6A
AC~
100~240VAC
100~240VAC
DBC4A1
A B C D
OFF
ON
Impedance
switch
BUS(IM) BUS(DS)
PC6A
AC~
ID=0
1
st
door station
ID=1
2nd door station
ID=2
3rd door station
ID=3
4th door station
L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S-
To monitors
RF CARD RF CARD RF CARD RF CARD
The door station work in Standard mode in this situation. Refer to Page 9 in detail.
The door station is also compatible with other monitors which are provided by our company.
-19-
Basic IN-OUT Wiring in Standard Mode
Connecting Multi Monitors
WIRING
The door station is also compatible with other monitors which are provided by our company.
Please set door station into group calling mode if there is more than 4 monitors in villa(Refer to Page 9)
Distributor is unnecessary in full audio system, and IN-OUT mode is recom­mended.
For the last monitor connected to the system, DIP6 should set to ON.
ID=0
Code=1, DIP6=off
Optional functional module
SCU camera module(max.4) GSM module(mobile phone transfer) TPS module(PBX transfer) QSW image quad splitter module
(Master)
Code=1, DIP6=off (Slave 2)
Code=1, DIP6=on (Slave 3)
BUS(IM) BUS(DS)
PC6A
AC~
100~240VAC
Code=1, DIP6=off (Slave 1)
RF CARD
SCU GSM TPS QSW
-20-
The door station is also compatible with other monitors which are provided by our company.
It can be extended 3 slave monitors for each monitor.(Better use with extra distributor for the
extension)
WIRING
DBC4A1
A B C D
RLC DBC4A1
OFF ON
Impedance
switch
BUS(IM) BUS(DS)
Code=1DIP6=on Code=2DIP6=on
Code=3DIP6=on Code=4DIP6=on
ID=0
RF CARD
PC6A
AC~
100~240VAC
Optional functional module
BDU
BDU bus amplifier module RLC staircase light controller module DBC4A1 2/4 inputs branch distributor
Star Topology Wiring With DBC4A1 in Standard Mode
-21-
Precautions
Specification
Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If necessary, please use a little pure water or dilute soap water to clean the dust.
The unit is weather resistant. However do not spray high pressure water on access control keypad directly. Excessive moisture may cause problems with the unit.
You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.
Pay attention to the high voltage inside the products, please refer service only to a trained and qualied professional.
APPENDIX
Power supply: DC 24V
Power consumption: Standby 0.8W; Working 3W
Camera lens: Color CMOS, 2.0 Mega pixel
1/2.7’’ sheye camera,170
0
wide angle
Lock Power supply: 12Vdc, 280mA(Internal Power);
Number of relay circuits: 2(the second lock need external device to support)
Mounting: Surface wall-mount / ush mount
Working temperature: -20ºC ~ +55ºC
Protection: IP54
Material: Zinc alloy panel(surface mounted)
Stainless steel panel(ush mounted)
Wiring: 2 wires, non-polarity
Dimension: 176(H)×90(W)×27(D)mm(surface mounted)
220(H)×119(W)×52(D)mm(ush mounted)
-22-
APPENDIX
Cables and Requirments
The maximum distance of the wiring is limited in the DT system. Using different cables may also
affect the maximum distance which the system can reach.
Cable and distance(unit:m)
Cable Usage A B
≤2 IMB≤16 IM
Twisted cable 2x0.75mm2 60 100 40
Twisted cable 2x1mm
2
80 120 60
A
B
RF CARD
PC6A
Basic IN-OUT Wiring Mode
-23-
B
A
C
2
2
DBC4A1
RF CARD
PC6A
Cable and distance(unit:m)
Cable Usage A B C
Twisted cable 2x0.75mm
2
60 60 30
Twisted cable 2x1mm
2
80 80 40
APPENDIX
Star Topology Wiring Mode With DBC4A1
The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.
DT-ENG-DT607-V1