VoxPower VCCM600S, VCCM600M User Manual

VCCM600 Series
AC/DC conduction cooled configurable power supplies
User Manual
_____________________________________________________________________________________________________
4”x7”x1.61”
SMALL
The VCCM600 series user manual has been prepared by our design team to assist qualified engineers in correctly
designing in the VCCM600 product into their application to achieve the best reliability and performance possible.
All specifications are beli eved to be correct at time of publishing. Vox Power Ltd reserves the right to make c hanges to any of its products and to change or i mprove any part of the specification, electrical or mechanical design or manufacturing process without notice. Vox Power Ltd does not assume any liability arising out of the use or application of any of its products and of any information to the maximum extent permitted by law. No license, expr ess or implied, by es toppel or other wise, to any intellectual property rights is granted by this document or by any pr oducts of Vox Power Ltd. V OX POWER LTD DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF SUITABILITY, FITNESS FOR PURPOSE, MERCHANTABILITY AND NONINFRINGEMENT. Please consult your local distributor or Vox Power directly to ensure that you have the latest r evision bef ore using the product and refer to the latest relevant user manual for further information relating to the use of the product. Vox Power Ltd products are not intended for use in connection with life support systems, human implantations, nuclear facilities or systems,
aircraft, spacecraft, military or naval missile, ground support or control equipment used for the purpos e of guidance navigation or direction of any aircraft , spacecraft or military or naval missile or any other application where product failure could lead to loss of life or catastrophic property damage. The user will hold Vox Power Ltd harmless from any loss, cost or damage resulting from its breach of these provisions.
600W
POWERFUL
SILENT
FAN-LESS
VCCM600 Series Overview
The VCCM600 series of conduction cooled configurable power platform delivers a silent 600 Watts and up to 750 Watts of peak power for 5 seconds in a rugged 4” x 7” package and is the ultimate power solution for applications where reliability or audible noise are of concern. The product combines the advantages of a modular power supply with the high reliability of a fan-less architecture. Depending on your application, the VCCM600 can be configured as a conduction, convection or forced air cooled solution and this versatility allows the unit to be seamlessly integrated across a vast range of applications, which makes it perfect for standardising your power platform. Designed with highest reliability and versatility in mind, the VCCM600 is suitable for applications ranging from the most controlled environments to the harshest conditions. Each configured modular solution can accommodate up to 4 isolated DC output modules which utilize 100% SMT components for increased reliability. Standard features include full output voltage adjust range, externally controllable voltage and current and series & paralleling of outputs. The unique design approach and heat dissipation techniques allows the unit to be mounted in virtually any orientation giving system designers even more flexibility. The series is approved to latest safety and EMC standards and features market leading specifications and design in application support.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manual
2 | P a g e
Contents
VCCM600 Series Overview 1 Part Numbers and Ordering Information 3 Important installation information 4 Theory of Operation 5 Input Module Operation 6 Input Module Protections 7 Efficiency Performance 8 Power Ratings 9 System Cooling 10 Signalling 13 Output Module Operation (A, B, C & D) 15 Advanced Output Module Features 18 Series Connected Outputs 22 Parallel Connected Outputs 23 Mechanical Dimensions and Mounting 26 Connector details 27 Safety 28 EMC Compliance 29 Reliability 31 Configuring Your VCCM Product 32 Accessories 37
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
3 | P a g e
Product Type
Part Numbers and Ordering Information
Input Module Detai ls
VCCM600S 600 Watt Input Module with ITE Approvals (IEC60950 Edition 2)
VCCM600M 600 Watt Input Module with Medical Approvals (IEC60601 Edition 3 + IEC60601-1-2 Edition 4 EMC)
Module Nominal v oltage Rated current Rated Power
OP 0 Unused slots OP A 5V 25A 125W 1.5V-7.5V ±50mV ±0.1%Vnom 9V OP B 12V 15A 150W 4.5V-15V ±100mV ±0.1%Vnom 18V OP C 24V 7.5A 150W 9V-30V ±150mV ±0.1%Vnom 36V OP D 48V 3.5A 150W 18V-58V ±300mV ±0.1%Vnom 66V
VCCM Input
Module
S - Standard M - Medical
Slot 1 - Output #
Slot 2 - Output #
VCCM600 S - A B C D - 0 0 0
Contact your Distributor or Vox Power for special configuration requirements. The factory may allocate a 3-digit suffix to identify such requirements.
INPUT MODULES
OUTPUT MODULES
Adjustment
range
PART NUM BERING SYSTEM
Load regu lat ion Line r egulation OVP
Factory use
USE '0' for unused slots.
Slot 4 - Output #
Slot 3 - Output #
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
4 | P a g e
temperature of 105°C.
Input Voltage
The input module power must be de
-
rated by 5W/VRMS below120 VRMS (600W @ 120 VRMS, 450W @ 90 VRMS)
Important installation information
The VCCM600 series of configurable power supplies are intended for use within end customer applications which restrict access to un-authorized personnel. The instructions in this manual and all warning labels on the product must be adhered to carefully.
SAFETY The VCCM600S and VCCM600M series are designed in accordance with the relevant safety requirements of UL60950-1, IEC/EN60950-1, UL60601-1, IEC/EN60601­1, CSA22.2 no 601-1, Low voltage Directive LVD 2014/35/EU and EMC directive EMC 2014/30/EU. All VCCM600 series power supplies must be installed correctly in a controlled environment which restricts access to any un-authorised personnel. Equipment and system manufacturers must protect service personnel against unintentional contact with the output terminals.
HAZZARDS Dangerous voltages are present within the power supply. It should only be handled by qualified personnel when the power supply has been disconnected from the mains supply voltage for more than 3 minutes. External surfaces of the power supply may become extremely hot during and after operation. Appropriate care should be taken. If series and/or parallel combinations of outputs exceed safe voltage and/or energy levels, the final equipment manufacturer must provide the appropriate protection for both users and service personnel.
DE-RATINGS
Ambient Temperature The input module power must be de-rated by 2.5%/°C above 50°C ambient up to a maximum ambient temperature of
Baseplate Temperature The output module power and current must be de-rated by 2.5%/°C above 85°C baseplate up to a maximum baseplate
Remember to take the appropriate de-rating into consideration before specifying any VCCM600 power supply for an application. If in any doubt, please contact Vox Power directly or your local Vox Power representative. HEALTH AND SAFETY To comply with section 6 of the health and safety at work act, a label that is clearly visible to service personnel must be placed on the final equipment. These labels warn that surfaces of the power supply may be hot and should not be touched when the product is operating.
FUSING The power supply has internal dual pole fusing. One fuse in each line. Fuses should only be replaced by authorised personnel and to ensure continued protection against risk of fire, fuses must be replaced with the same type and rating of fuse. For DC operation, an appropriately rated DC fuse must be included in the end application.
SERVICING The power supply contains no user serviceable parts. Repairs must be carried out by authorised personnel only. Contact Vox Power for further information.
APPR OVAL LIMITA TIONS – NORTH AMERICA When this product is used with 180VAC–253VAC mains where no neutral is present, connect the two live wires to L (Live) and N (Neutral) on the input connector.
COOLING For proper operation of the power supply, the user must ensure sufficient cooling to maintain all component temperatures within specifications. A thorough review of the user manual should be carried out for details of thermal performance.
EART H TERMINAL MARKING To comply with the requirements of UL60950-1, IEC/EN60950-1, CSA22.2 no. 60950-1, UL60601-1, IEC/EN60601-1, CSA22.2 no 601-1 where the incoming wiring earth is intended for connection as the main protective earth conductor and where the terminals for such a connection is not supplied on a component or subassembly, the user shall add an appropriate label displaying a protective earth symbol in accordance with 60417-2-IEC-5019 directly adjacent to the terminal. The label should be durable and legible and should withstand the 15 second rub test as per UL60950-1 section 1.7.15.
WARRANTY Contact your sales agent or Vox Power for product repairs. See Vox Power standard terms and conditions for warranty conditions.
PRODUCT LABELS The external product label contains information relevant to the power system. The label contains input voltage, maximum input current, input frequency, maximum output power, fuse rating and type, serial number, approvals and product part number in form VCCM600x-yyyy-zzz.
VCCM OUTPUT MODULES Each output module label contains information relevant to that output. The label contains voltage adjustment range, maximum output current, serial number, approvals and the part number in format OPx.
OTHER
A label warning that external surfaces are hot during operation and that the unit should be allowed to cool down properly should be placed on the
unit where such a label is clearly visible.
The VCCM600 series is designed to comply with EMC standards but it does not imply that the end system will comply. To prolong the life of the unit, use in dust free environment. Units can sometimes be damaged during transit. In the event of transit damage, DO NOT connect power to the unit. Contact your sales agent or Vox
Power.
Always use adequately sized cables and ensure good crimp connections. Use cable supports to minimise stress on connectors. Avoid excessive shock or vibration.
70°C.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
5 | P a g e
Theory of Operation
The diagram below outlines the topology and major internal components of a fully assembled VCCM600 configurable power supply. Four output slots are provided and can be populated by any combination of
transformer modules
.
output modules
. The remaining components in the block diagram are housed in the
input
and
The
input module
disturbances and preventing excessive EMI emissions and current harmonics. The integrated EMI filter attenuates high frequency current emissions to levels below EN55022 class B. It also provides dual pole fusing, one fuse in each conductor and protection from line disturbances as outlined in EN61000.
Inrush current is controlled by a resistive element upon initial connection to the AC line. Once the internal capacitances have been charged, the resistive element is bypassed to reduce losses.
Active Power Factor Correction (PFC) is used to ensure an accurate input current waveform with extremely low harmonic content, exceeding the requirements of EN61000. This stage also provides active input current limiting which prevents overloading of the input stage while maintaining high power factor.
The output of the PFC stage charges the hold-up electrolytic capacitors which store enough energy to allow the VCCM600 configured product to continue operating during minor line disturbances. Long lifetime and high temperature capacitors are used which ensures extended lifetime and product reliability.
A highly efficient zero voltage switching circuit is used to drive the isolated transformer from the hold-up capacitors. The output modules connect to the transformer secondary and provide safe isolated power to a high performance synchronous rectifier power converter. This power converter is controlled using the latest analog control technology to produce superior output performance in a miniature size.
is responsible for receiving the AC mains line voltage and converting it to an appropriate DC voltage whilst providing protection from AC line
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
6 | P a g e
J11 J2 Operational mode
Comm ents
Open Closed
STANDBY
<1W power consumption
Note -
J12 is reserved for internal use. Do
not short J12
- +
Input Module Operation
Startup & Shut Down
The VCCM input module operates from a universal input voltage range and s tarts automatically upon application of adequate AC mains voltage (>84Vrms). After a short delay, the global 5V bias supply starts and the ACOK signal goes high to indicate that the mains voltage is present and input stage is operating correctly. Once the ACOK signal is high, the output modules turn on and deliver power to the application loads. The power good signals will indicate that the output voltages are within specification. The diagram bel ow shows the normal start up/shut down sequence and gives typical timings.
Typical timing values at 120Vac 600W 25°C: t
When the AC mains voltage is removed, the internal hold-up capacitors will supply power to the load for typically 20 ms (t4+t5) at maximum power. The ACOK signal will go low at least 5ms before the output voltages fall below the power good threshold level. This allows the application to prepare for the impending loss of power. The 5V bias supply will remain on for typically 100ms, after the output modules have turned off.
*Output modules that are adjusted above nominal voltage, will have reduced ACOK warning time.
500 ms, t
1
170 ms, t
2
3
1500 ms, t
≥15 ms, t
4
≥5ms (minimum), t
5
≥100 ms
6
Standby control
The unit may be completely shut down by shorting (<10Ω) the terminals of J2. The unit will restart once the short is released. The control uses transformer coupled pluses to detect the short and is fully isolated to 2xMOPP. The voltage present on J2 ranges from +3.3V to -0.8V with a peak current of 15mA. In active mode, the control is pulsed every 1.3mS while in standby mode the control is pulsed every 400mS. A signal MOSFET or switch may be used to activate this control. This shutdown will not generate the ACOK warning signal.
Programmable start-up state
The start-up and standby control logic can be inverted by shorting J11 with a jumper. The functionality is shown in the table below.
Open Open NORMAL Default. Unit will start into NORMAL mode
Closed Open STANDBY Unit will start into STANDBY mode. <1W power consumption Closed Closed NORMAL
J2 LOCATION
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
J11 LOCATION
J11
J12
DOC-MN-007-03 VCCM600 User Manual
7 | P a g e
Hold-up
For short line distubances (<20ms), the output voltages will not be affected*. However, the ACOK signal may still go low to warn that there is an impending loss of output power. The ACOK signal will return to the high state once the unit has recovered from the disturbance.
*Output modules that are adjusted above the hold-up voltage (as detailed in their respective datasheets), may experience a dip in voltage.
No Load Power/Standby Power Consumption
The no-load power consumption of the VCCM600 series PSU is extremely low when compared to similar configurable power supplies. With the output modules enabled the unit typically only requires less than 15W with no output load. To reduce the no-load power further the outputs can be disabled using the inhibit pins. With the outputs disabled the unit typically requires less than 10W. When the unit is in the standby (latched off) state, the power consumption is less than 1W.
Peak Power capability
The input module can provide a peak output power of up to 750W for a period of up to 5 seconds, provided the input current remains below the over current protection threshold. Peaks of power lower than 750W can be supported for longer times provided the excess watt-seconds are equivalent. For example, 750W peak for 5 seconds is an excess power of 150W*5s = 750Ws. 650W can be supported for 750Ws/50W = 15s. When using peak power capability, the user must ensure the average power remains within ratings. Note that input module de-ratings apply to both rated power and peak power.
Input Module Protections
Over current protection (OCP)
The input module is protected from excessive input current by means of an over current protection circuit which limits the input current to approximately 7Arms. If the OCP threshold is exceeded the unit may shut down and attempt to automatically restart. This shutdown will generate the usual ACOK warning.
Under voltage protection (UVP) & Brown-Out Protection (BOP)
The input module is protected from excessively low input voltages by under voltage and brown out protection circuits that senses the input line voltage. The under-voltage protection circuit maintains the unit in standby mode until the input voltage rises above the UVP threshold as detailed in the datasheet. Once the unit is active, the brown out protection monitors the input voltage and shuts down the unit when input voltage goes below approximately 60Vrms. This shutdown will generate the usual ACOK warning. The unit will restart once the input voltage increases above the UVP threshold.
Over Temperature Protection (OTP)
The input module is protected from excessive temperatures by means of various internal temperature sensors. If temperature thresholds are exceeded the entire unit may latch off, with no ACOK warning. To re-enable the unit, it must be allowed to cool, then either disconnect the AC mains for approximately 20 seconds, or toggle the standby control on J2.
Over Power Protection (OPP)
The input module is protected from excessive power by means of an over power protection circuit. Should the rated power be exceeded the unit will shut down and attempt to recover automatically. This shutdown will not generate the usual ACOK warning.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
8 | P a g e
Efficiency Performance
The efficiency of the configured VCCM600 product is dependent on parameters such as input line voltage, load level and on the combination of output modules. The plots below show typical efficiencies of a VCCM600 product fitted with all modules A, B, C or D. The plots cover the full load and line voltage range. All modules are adjusted to nominal voltages and are equally loaded.
0.91
0.90
0.89
0.88
0.87
0.86
0.85
0.84
0.83
0.82
0.81
Efficiency
0.80
0.79
0.78
0.77
0.76
0.75
0.74
0.73
0.91
0.90
0.89
0.88
0.87
0.86
0.85
0.84
0.83
0.82
0.81
Efficiency
0.80
0.79
0.78
0.77
0.76
0.75
0.74
0.73
Typical Load Efficiency at 120V
OPA OPB OPC OPD
0 50 100 150 200 250 300 350 400 450 500 550 600
Output Power (Watts)
Typical Load Efficiency at 85V
OPA OPB OPC OPD
0 50 100 150 200 250 300 350 400 450
Output Power (Watts)
input voltage
RMS
input voltage
RMS
0.91
Typical Load Efficiency at 220V
0.90
0.89
0.88
0.87
0.86
0.85
0.84
0.83
0.82
0.81
Efficiency
0.80
0.79
0.78
0.77
0.76
0.75
0.74
0.73 0 50 100 150 200 250 300 350 400 450 500 550 600
0.91
0.90
0.89
0.88
0.87
0.86
0.85
0.84
0.83
0.82
0.81
Efficiency
0.80
0.79
0.78
0.77
0.76
0.75
0.74
0.73
Typical Line Efficiency at maximum rated power
80 100 120 140 160 180 200 220 240 260
OPA OPB OPC OPD
Output Power (Watts)
OPA OPB OPC OPD
InputVoltage (V
)
RMS
input voltage
RMS
An estimate of the overall efficiency for any configured system may be obtained from these graphs.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
9 | P a g e
Normal ised V
Ratin g [A]
1 0.708 0.708 1 1 0.833 1
Bias su pply powe r [5W* C]
5 5 5 3.75 2.5 3.75 2.5
OPA P
[125W
/187 .5W
*E]
125/187.5
88.5/132.75
88.5/132.75
93.75/140.625
62.5/93.75
78/117 62.5/93.75
OPC I
[7.5A *C]
7.5 7.5 7.5 5.625 3.75 5.625 3.75
OPD P
[150 W
/21 7.5W
*E]
150
/217.5 106.2
/154 106.2
/154 112.5
/163.125 75
/108.75 93.6
/135.72 75
/108.75
Power Ratings
VCCM600 series products must always be operated within stated operating limits. Equipment manufacturers and other users must take the appropriate de-rating into account when specifying a unit for the intended application. If in doubt, contact your sales representative or Vox Power for assistance.
There are three main de-ratings for the VCCM600 series of configurable power supplies when used in a conduction cooled application,
1. Ambient air temperature
Ambient air temperature de-ratings apply to the input module rated and peak power only.
(3)
The input module must be de-rated by 2.5% per degree Celsius above 50°C, up to a maximum of 70°C.
2. Basep late temper ature
Baseplate temperature de-ratings apply to output module rated power, peak power and rated current, and bias supply power.
The output module parameters must be de-rated by 2.5% per degree Celsius above 85°C, up to a maximum of 105°C.
3. Input li ne voltage
Input line voltage de-ratings apply to the rated power and peak power for both the input module and output module.
All parameters must be de-rated by 2.5% for every 3 volts below 120Vrms, down to a minimum of 85Vrms.
Notes:
1. Ambient air temperature is the air temperature immediately surrounding the PSU.
2. Baseplate temperature is measured at baseplate temperature sensing location TS1.
3. A normalized value of 1 is equivalent to 100%.
4.
Input l ine volt age der atings a re c umulati ve with t emperatu re derat ings.
1 2 3 4 5 6 7 VIN (V
)
RMS
AMBIENT
BASE
(⁰C )
RATED
RATED
RATED
RATED
(⁰C )
RATED/PEAK
RATED/PEAK
RATED/PEAK
RATED/PEAK
IN
Rat ing [B]
AMBIENT
Rat ing [C]
BASE
[600 W/750W*D ]
RATED/PEAK
25 25 25 18.75 12.5 18.75 1 2.5
[25A* C]
[150 W/225W*E]
[15A* C]
[150 W/225W*E]
[3.75 A*C]
150/225 106.2/159.3 106.2/159.3 112.5/168.75 75/112.5 93.6/140.4 75/112.5
15 15 15 11.25 7.5 11.25 7.5
T Normal ised T T Normal ised T
Normal ised Tot al input rating [A*B = D] Normal ised Tot al outpu t rating [A*C = E]
Input module P
OPA I OPB P OPB I OPC P
OPD I
(1)
(2)
(3)
Examples of po wer ratings calc ulation f or variou s input voltag es, ambient tempera tures and bas eplate t emperature s
120 85 85 120 120 100 120
70 50 70 50 6 0 60 50
0.5 1 0.5 1 0.75 0.75 1 85 85 85 95 105 95 105
1 1 1 0.75 0.5 0.75 0.5
0.5 0.708 0.354 1 0.75 0.624 1 1 0.708 0.708 0.75 0.5 0.624 0.5
300/375 424.8/531 212.4/265.5 600/750 450/562.5 374.4/468 600/750
150/225 106.2/159.3 106.2/159.3 112.5/168.75 75/112.5 93.6/140.4 75/112.5
3.75 3.75 3.75 2.8125 1.875 2.8125 1.875
1.1
1
0.9
0.8
0.7
0.6
Normalised output power rating
0.5
0.4
-40 -30 -20 -10 0 10 20 30 40 50 60 70
1.1
1
0.9
0.8
0.7
0.6
0.5
Normalised Power & Current Rating
0.4
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
1.1
1
0.9
0.8
0.7
0.6
Normalised Output Power rating
0.5
0.4 80 100 120 140 160 180 200 220 240 260 280
Ambient Temperature Derating
Derate at 2.5% per degree celcius
above 50 degree celcius
Ambient Temperature (Celcius)
Temperature Derating
Derate at 2.5% per degree celcius
above 85 degree celcius
Baseplate Temperature (Celcius)
Input Line voltage Derating
Derate at 2.5% per every
3 volts below 120Vrms
Input Voltage (RMS)
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
10 | P a g e
Orientation definitions
A B C D E F
System Cooling
The power ratings shown in the previous section are for conduction cooling, however the unit may be operated with forced air cooling, convection cooling or combinations of all three. To assist in specifying the product for these applications, the typical thermal performance has been characterised under controlled conditions. The ratings achieved are based on maintaining the baseplate temperature within the conduction cooled ratings specified on page 9.
550 500 450 400 350 300
Pout
250
OPA 120Vin, 4x5Vout
200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 6 0 70 80
650 600 550 500 450 400 350 300
Pout
250 200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 6 0 70 80
A B CD EF
Ambient Temperature
OPB/C/D 120Vin, 4x10/20/40Vout
A B CD EF
Ambient Temperature
CONVECTION PERFORMANCE WITH HEATSINK
Natural Convection, With Heatsink, Free Air, Mounting Orientations A/B/C/D/E/F
Natural Convection, No Heatsink, Free Air, Mounting Orientations A/B/C/D/E/F
550 500 450 400 350 300
Pout
250
OPA 120Vin, 4x5Vout
200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 6 0 70 80
650 600 550 500 450 400 350 300
Pout
250 200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 6 0 70 80
A B CD EF
Ambient Temperature
OPB/C/D 120Vin, 4x10/20/40Vout
A B CD EF
Ambient Temperature
Orientation
CONVECTION PERFORMANCE
550 500 450 400 350 300
Pout
250
OPA 220Vin, 4x5Vout
200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80
650 600 550 500 450 400 350 300
Pout
250
OPB/C/D 220Vin, 4x10/20/40Vout
200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80
550 500 450 400 350 300
Pout
250
OPA 220Vin, 4x5Vout
200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80
650 600 550 500 450 400 350 300
Pout
250
OPB/C/D 220Vin, 4x10/20/40Vout
200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80
A B CD EF
Ambient Temperature
A B CD EF
Ambient Temperature
(1)
A B CD EF
Ambient Temperature
A B CD EF
Ambient Temperature
definitions
Notes
1. Standard Vox heatsinks type 1 and type 2 used. Type 1 used for mounting orientations A, B, E and F. Type 2 used for mounting orientations A, B, C and D.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
11 | P a g e
Airflow
definitions
X Y Z
2. Standard Vox heatsinks type 1 and type 2 used. Type 1 used for
airflow direction X
. Type 2 used for
airflow direction Y
.
550 500 450 400 350 300
Pout
250
OPA 120Vin, 4x5Vout
200 150 100
50
0
650 600 550 500 450 400 350 300
Pout
250 200 150 100
50
0
2MS-1 1.5MS-1 1 MS-1 0.5MS-1
-40 -30 -20 -10 0 10 20 30 40 50 6 0 70 80 Ambient Temperature
OPB/C/D 120Vin, 4x10/20/40Vout
2MS-1 1.5MS-1 1MS-1 0.5MS-1
-40 -30 -20 -10 0 10 20 30 40 50 6 0 70 80 Ambient Temperature
FORCED AIR PERFORMANCE WITH HEATSINK
With Heatsink, Air Direction X or Y at 2MS-1/1.5MS-1/1MS-1/0.5MS-1
550 500 450 400 350 300
Pout
250
OPA 120Vin, 4x5Vout
200 150 100
No Heatsink, Air Direction X or Y at 2MS-1/1.5MS-1/1MS-1/0.5MS-1
50
0
650 600 550 500 450 400 350 300
Pout
250 200 150 100
50
0
2MS-1 1.5MS-1 1MS -1 0.5MS-1
-40 -30 -20 -10 0 10 20 30 40 50 6 0 70 80 Ambient Temperature
OPB/C/D 120Vin, 4x10/20/40Vout
2MS-1 1.5MS-1 1MS-1 0.5MS-1
-40 -30 -20 -10 0 10 20 30 40 50 6 0 70 80 Ambient Temperature
FORCED AIR PERFORMANCE
550 500 450 400 350 300
Pout
250
OPA 220Vin, 4x5Vout
200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80
650 600 550 500 450 400 350 300
Pout
250
OPB/C/D 220Vin, 4x10/20/40Vout
200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80
550 500 450 400 350 300
Pout
250
OPA 220Vin, 4x5Vout
200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80
650 600 550 500 450 400 350 300
Pout
250
OPB/C/D 220Vin, 4x10/20/40Vout
200 150 100
50
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80
2MS-1 1.5MS-1 1MS-1 0.5MS-1
Ambient Temperature
2MS-1 1.5MS-1 1MS-1 0.5MS-1
Ambient Temperature
(2)
2MS-1 1.5MS-1 1MS-1 0.5MS-1
Ambient Temperature
2MS-1 1.5MS-1 1MS-1 0.5MS-1
Ambient Temperature
Notes
1. Each 0.5MS-1 is approximately 100LFM. Eg. 2MS-1 400LFM, 1.5MS-1 300LFM etc.
The ratings provided above are for guidance only and all VCCM600 configured solutions must be evaluated in the end application to ensure the conditions set out in the power ratings section are met.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
12 | P a g e
Specifying the VCCM600 product for convection or forced air cooling
To specify a VCCM600 ser ies product for an end application, the required output power, minimum input line voltage, maximum ambient, mounting orientation and air flow rate (if applicable) should be determined. Check the requirements against the closest characteristic plot from the tables above to ensure ratings can be achieved. Be conservative when specifying the product as convection and forced air cooling can be highly dependent on the end application enclosure and power supply mounting. The estimated performance must be verified in the end application and temperatures may exceed predicted levels. It is also important to note that ambient temperature refers to the ambient temperature immediately surrounding the PSU. If the PSU is mounted within an enclosure the enclosure ambient temperature is likely to be higher than the external air ambient temperature.
Evaluating the VCCM600 product in the end application
To ensure the product is operating within its ratings in the end application the following procedure should be performed during the design stage.
1. Install a thermocouple in position TS1 of the product. (See Mechanical dimensions and mounting for details.) The thermocouple wire should exit on the top side between slots 2 and 3. The bottom side should be flush for heatsink mounting if necessary. Glue should be used to hold the thermocouple in place.
2. Setup the application in worst case conditions, considering Input line voltage, Output power, ambient temperature, airflow and cooling restrictions.
3. Power the system and monitor the baseplate temperature until it reaches steady state.
4. Ensure that under worst case conditions, the baseplate temperature cannot exceed the rated temperature as outlined in the power ratings section of
If a cover is placed over the primary components, then the following component temperatures must also be measured to ensure they are below the maximum specified temperatures.
this manual.
Descr iption Reference Maximum allowed temperature Drawing
Fuse FS1, FS2 125°C
Electrolytic capacitors C12 105°C
Inductors L1, L2, L3, L5
Other capacitors C1, C4 110°C
If excessive temperatures are measured during this evaluation, then one or more of the following remedies may improve thermal performance.
Increase heatsink size Increase airflow rate Improve air intake & outlet Reduce power requirement
130°C
Using the internal temperature sensor to control external application cooling
An internal temperature sensor T transformer temperature and can be used to control external cooling systems or to provide a warning of impending over temperature protection. The internal temperature (T possible in any given application.
is available on J3 pin 9 (See page 14 for details). The output voltage of this sensor gives a measurement of the internal
SNS
) should never exceed 120⁰C (2.74V), however, system reliability will be maximised if the PSU temperature is maintained as low as
SNS
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manual
13 | P a g e
1
2
11
12
Signalling
Global Signals
To reduce cabling in the end system, all major input and output signals and the global 5V bias supply are wired to a single signals circuit that is accessed through connector J3 on the transformer module as shown in the diagram below.
J3 – Global Signals
Pin Name Description
1 PG4 Slot 4 Power Good
2 INH4 Slot 4 Inhibit
3 PG3 Slot 3 Power Good
4 INH3 Slot 3 Inhibit
5 PG2 Slot 2 Power Good
6 INH2 Slot 2 Inhibit
7 PG1 Slot 1 Power Good
8 INH1 Slot 1 Inhibit
9 T
10 ACOK AC mains signal
11 +5V 5V Bias supply
12 COM Common
Temperature sense
SNS
All the signals are referenced to the bias supply common rail (COM) and external control and/or monitoring circuits can be easily powered and interfaced to the PSU through this connector. The entire signals circuit is fully medically isolated and can be considered a SELV output. The table below lists the isolation voltages.
Signals to Input 4000 VAC Signals to Chassis 500 VDC Signals to Output 500 VDC
Signals isolation voltages
Bias Supply (+5V [Power])
The VCCM600 series has one isolated bias supply located on the trans former module (J3) beside slot 4. The output side bias supply generates 5V and is rated up to 1A. The supply is available whenever the AC mains voltage is connected and the input module is operating correctly. A shutdown through the standby control on J2 or any of the following abnormal conditions will disable the 5V bias supply:
Over temperature of any part of the unit Over voltage on any output module Internal over current (device failure)
AC Mains Signal (ACOK [Output])
An ACOK signal is provided to indicate to the user that the AC mains voltage is applied and the input module is operating correctly. The output signal is driven from an internal operational amplifier. Under normal operating conditions this signal gives a warning of 5ms before the output voltage falls below the power good threshold. A shutdown through the standby control on J2 or any of the following abnormal conditions may cause the unit to turn off without the minimum 5mS ACOK warning:
Over temperature of any part of the unit Over voltage on any output module Internal over current (device failure)
*Output modules that are adjusted above nominal voltage, will have reduced ACOK warning time.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manual
14 | P a g e
Power Good Signals (PG1-PG4 [Output])
Each output module provides a power good (PG) signal to indicate when the output voltage is above approximately 90% of the pre-set voltage for that module. Each PG signal on an output module is internally connected through an opto-isolator to the signals circuit, which provides and open collector output, as shown.
The LED on the front of each module gives a visual confirmation of the PG status.
Note that remote adjustments of the output voltage using the V
CONTROL
and I
CONTROL
pins do not change the PG signal threshold. The PG threshold is always approximately 90% of the voltage set with the manual potentiometer.
Output Inhibits (INH1-INH4 [Input])
The signals circuit provides an inhibit input to disable each output module individually. Each inhibit input is internally connected through an opto-isolator to the respective output modules. The basic internal electrical circuit and timing diagrams are shown below.
Internal circuit Timing: Typically, t
Internal Temperature sensor (T
[Output])
SNS
An internal temperature sensor is embedded in the transformer module. The output voltage of this sensor gives a measurement of the internal transformer temperature and can be used to control external cooling systems or to provide a warning of impending over temperature protection. The sensor output voltage is related to temperature as follows,
120
T
output voltage Vs Internal Temperature
SNS
100
V = 0.4 + 0.0195*T
The sensor will accurately measure temperatures in the range -10⁰C to +125⁰C. The internal temperature should never exceed 120⁰C (2.74V)
80
60
40
20
0
-20 0 0.5 1 1.5 2 2.5
= 100 μs and tON = 8 ms.
OFF
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manual
15 | P a g e
Output Module Operation (A, B, C & D)
Power Profile
The power profile diagram below is a voltage/current plot that together with the associated table provides details of the main features of the currently available output modules.
Parameter
V
NOM
V
MIN
V
MAX
V
OVP
I
RATED
I
(A) 27.5 16.5 8.25 4.125
OCP
V
SCP
I
(A) 22 13.2 6.6 3.3
SCP
P
RATED
P
(W) 187.5 225 225 217.5
PEAK
OPA OPB OPC OPD
(V) 5 12 24 48 (V) 1.5 4.5 9 18 (V) 7.5 15 30 58 (V) 9.5 17 32 66
(A) 25 15 7.5 3.75
(V) 1 2 4 4
(W) 125 150 150 150
Output Voltage Adjustment
Each output can be adjusted within the range as described in the table above or in the datasheet. Voltage adjustment can be achieved by two methods;
1. Manual potentiometer adjustment Using the manual adjust potentiometer (located beside the “Power Good” indicator on the top of each output module), the preset output voltage (V output module is adjustable over the entire range of V
to V
MIN
as specified in the power profile table above. A clockwise rotation of the potentiometer results in
MAX
) of each
SET
an increase of the output voltage while an anti-clockwise rotation results in a decrease of the output voltage.
2. Remote Voltage Programming Using remote voltage programming, the output voltage may be adjusted beyond the V
MIN
and V
range specified in the power profile table above. However,
MAX
certain precautions must be taken to ensure correct operation. Please see the “Advanced output module features” section for more details.
Over Voltage Protection (OVP)
In the event of an output module fault, the modules are protected against excessive output voltages. This is implemented as a fixed voltage threshold V table above. If the output voltage exceeds this threshold, all outputs will be disabled temporarily. If the fault persists after 20mS the entire unit will be latched off, otherwise the outputs will auto recover. To resume operation of a latched unit, disconnect the AC input voltage for 5 seconds or toggle the standby control on J2. Note that no warning is given on the AC_OK signal for faults of this type.
OVP
, in the
Over Current & Short Circuit Protection (OCP & SCP)
For increased safety and reliability all output modules in the VCCM series have over current and short circuit protection. The over current threshold is typically set at 115% of the rated current and has a constant current, straight line characteristic that reduces the output voltage as the load resistance decreases. If the output voltages falls below the short circuit voltage threshold (V scheme to reduce system losses and potential damage. When in this mode, the output will be enabled for approximately 3% of the time, disabled for 97% and will attempt to restart at approximately 125 ms intervals. The module remains in this state until the short circuit condition is removed, at which point normal operation resumes.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
) the module enters short circuit protection mode. In this mode the output module uses a hiccup
SCP
DOC-MN-007-03 VCCM600 User Manual
16 | P a g e
OP C
A 12mF
C 1mF
Reverse Current Protection (RCP)
The standard output modules use synchronous rectification in the output stages to achieve high efficiency and as a result the outputs can both source and sink current. The sink current is internally limited to approximately -6% of the maximum rated current. However, in applications where the output modules are connected to external power sources such as batteries or other power supplies certain precautions must be observed to prevent damage to the unit.
The outputs should never be directly connected to to external power sources without some form of reverse current protect ion such as an external diode or controlled mosfet. If protection is not used, large reverse currents which will ultimately result in damage to the unit will occur, especially when the AC mains is disconnected.
Output Module Average and Peak Power
All modules have an average and peak power rating. The average power of each unit must at all times remain below it’s specified limit. However, each output can deliver up to 150% of it’s average power rating for a maximum of 5 seconds at 50% duty cycle, subject to the current limit not being exceeded and subject to the overall average power drawn being less than the specified average power rating (including any input derating due to temperature or line voltage). The available peak power is a function of the output voltage and maximum current for each module. Full peak power is only possible when the output voltage is adjusted to V
and the maximum current is drawn from the module. Note that both average and peak power ratings are subject to the same temperature derating as the
MAX
input module (derate by 2.5% per °C above 50°C), but are not subject to any line derating.
Start-up & Shut Down
All outputs are designed to have a regulated monotonic start-up with a rise time of approximately 3ms as shown in the diagram right. The power good signal will not assert until the voltage exceeds the power good threshold (≈90%).
Where multiple output modules are used, the default start up scheme is ratio-metric with all outputs starting at the same time as shown in the diagram right. External control circuits may be used to implement tracking or sequenced start up if necessary.
The outputs are not designed to start into pre-biased loads and may discharge any externally capacitance before beginning to ramp the output voltage up in the normal way.
At shutdown, the outputs enter a high impedance state. Where no external load is present it may take some time for the voltage to decay. When driving inductive loads, care must be taken to limit the voltage at the output terminals to prevent damage to the unit.
Synchronisation
All output modules in the same product are synchronised. The typical operating frequency is 260kHz and paralleled or series connected units will not produce ripple beat frequencies.
External capacitance
All outputs can support a large external capacitance as detailed in the table shown. The capacitances specified ensure monotonic start-up with rated load applied. Larger capacitances can be applied for lower load currents.
EXT_ MAX
B 4mF
D 500uF
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manual
17 | P a g e
Ripple and Noise
The ripple and noise figures stated in the datasheet are defined based on a standard measuring method. To obtain the same results the same test setup must be used and care must be taken to eliminate any parasitic noise pickup. The diagram below shows details of the setup and sources of noise pickup.
Over Temperature Protection (OTP)
Each output module is protected against excessive temperatures. In the event of an internal temperature exceeding safe levels the output module will shut off. If the temperature reduces the output module will automatically recover. Should the temperature continue to rise a second over temperature circuit will shut down the input module and all outputs. To resume operation of the unit, disconnect the AC input voltage for 20 seconds then reconnect. If all temperatures are within specifications the unit will restart. Note that no warning is given on the AC_OK signal for faults of this type.
Transient Response
The VCCM output modules have been especially designed to have high reliability. To achieve this all electrolytic capacitors have been eliminated from the design. As a result of this, high dynamic load transients can cause relatively high voltage deviations at the output and although the outputs have a very high loop bandwidth with typical recovery times of less than 100μs, the voltage deviations may still be excessive for some applications.
An example application is detailed in the diagram below and shows typical responses at the terminals of the output module and at the load. Notice that the voltage deviation due to cable inductance exceeds the module response and hence a capacitor located at the module terminals will have little effect at the load. The optimum solution is to locate a low impedance electrolytic capacitor at the load which will eliminate the inductive cable drop and reduce the typical voltage deviation at the module.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
18 | P a g e
Equivalent internal circuit
Control function
Advanced Output Module Features
Remote Voltage Programming (External Voltage Control)
The output voltage of the module can be adjusted using an external voltage source connected between the COM and V as shown below.
In this configuration the output voltage will follow the typical equation below,
VO = V
((5-V
SET
) / 3.8), where V
CONTROL
is the manual preset voltage of the module.
SET
pins on the signals connector J4
CONTROL
The output voltage can be controlled from 0% to 131.5% of the preset voltage using this control method. However, care must be taken to ensure the output voltage does not exceeed the OVP level, as this will trigger OVP protection.
Remote adjustment of the output voltage using the V
pin does not affect the preset power good threshold. Hence, remotely adjusting the output voltage
CONTROL
below 0.9*Vset will cause the power good signal to go low.
Where tight voltage adjustment tolerances are required, it is recommended to use external circuitry to provide closed loop control of the V
CONTROL
pin.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
19 | P a g e
Equivalent internal circuit
Control function
Remote Current Programming (External Voltage Control)
The output current limit of the module can be reduced using an external voltage source connected between the COM and I as shown below. In practice this also means that the output can be used as a modulated or constant current source.
In the diagram above, Vi_out is an internal voltage source that is proportional to the internal inductor current and approximates the equation,
V
I_OUT
= 4*I
, where Irated is the maximum rated current for the module.
OUT/IRATED
pins on the signals connector
CONTROL
In this configuration the output current limit will approximate the following equation,
I
LIMIT
= I
RATED*VCTRL
/4, where I
is the maximum rated current for the module.
RATED
It is not possible to increase the maximum current limit of the module, and control voltages exceeding 4.6V will have no effect on the current limit.
When using an output module as a modulated current source, the output voltage should be manually adjusted to the maximum that will be required by the application and this will be the upper voltage limit. Once the load is connected, the output current can then be modulated by applying a control voltage as described above.
Note that the power-good threshold level is fixed and defined by the manually preset voltage. Hence, while the output module is limiting or modulating the output current the PG signal may go low.
Where tight current adjustment tolerances are required, it is recommended to use external circuitry to provide closed loop control of the I
CONTROL
pin.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
20 | P a g e
Output Current Measurement
The output current of the module can be measured using the I
V
I_OUT
= 4*I
OUT/IRATED
, where I
is the maximum rated current for the module.
RATED
signal. If this pin is not loaded its output voltage will follow the typical equation,
CONTROL
Note that the I during dynamic events. It is recommended to add an external buffer amplifier (as shown below) when using the I loading the I
output voltage is representative of the internal inductor current not the actual load current. However, this will only have an influence
CONTROL
signal, even with microamps can cause the current limit to be reduced. If it is required to measure the output current and adjust the output
CONTROL
signal to measure the output current as
CONTROL
current limit simultaneously, this can be achieved by using a clamp circuit instead of a voltage source to adjust the current limit, while continuing to use an amplifier to measure the output current. An example circuit is shown below. In this case V
will control the current limit while the buffered I
CONTROL
CONTROL
signal will
provide a measurement of the output current.
Measuring output current
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
Measuring & controlling output current
DOC-MN-007-03 VCCM600 User Manua l
21 | P a g e
Remote Sensing
Remote sensing is available on all output modules and can be used to compensate for a voltage drop in the power leads connecting the power supply to the load. To implement remote sensing connect the positive sense pin (S+, connector J4.2) to the positive side of the remote load and the negative sense pin (S-, connector J4.1) to the negative side of the remote load. The voltage will be regulated at the points where the sense cables are connected.
Active protection against damaged power cables or accidental power cable removal is provided and prevents damage to the unit in each case. An internal circuit measures the voltage between S+ to V+ and S- to V-, when this voltage exceeds the thresholds specified in the datasheet, the output voltage is reduced t o benign levels. During system design, care must be taken to ensure power cables have a sufficiently low voltage drop at maximum load current to ensure this protection does not activate unintentionally.
In systems where remote sensing is not used, the output voltage at the power terminals will be slightly higher than that at the sense terminals. This voltage difference is termed, “open sense offset” and occurs due to internal bias currents in the sensing circuit. Factory set units are set with the sense cables connected unless otherwise specified.
Local Bias Supply
A local non-isolated +5V bias supply is provided on each output module (+5 V on J4.6, referenced to COM on J4.3). This supply is intended to power interface circuits for monitoring and controlling the output modules. The output can supply up to 10mA maximum, and exceeding this can damage the unit.
Also, as COM is connected to an internal voltage that is to any control circuit in the application. Connecting COM to S- or V- may result in damage to the unit.
equivalent to S- or V-, particular attention must be given to grounding issues when interfacing COM
NOT
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
22 | P a g e
Series Connected Outputs
VCCM output modules of the same type can be series connected to achieve higher output voltages. Links for series connecting modules are available directly from Vox Power or our local representatives.
The following instructions must be followed for output modules configured in this manner.
WARNING!
Energy and Voltage hazards may arise when individual modules are series connected. See the Safety section for more details. When modules are connected in series, their inhibit lines (J3), if used, should be paralleled. Inhibiting series connected modules individually may cause damage
Isolation to Ground
Care must be taken not to exceed the output module isolation to chassis ground when series connecting modules. Each output module is rated for 500 Volts maximum between each output terminal and chassis ground. Exceeding this voltage may damage the module.
Remote Sensing
For series connected modules, remote sensing is achieved by connecting the upper most positive sense terminal (S+) and the lower most negative sense terminal (S-) from the series of modules to their respective load regulation points. All inner sense terminals in the series must be daisy chained i.e. S+ to S- from the first module in the series to the last module in the series. An example of two series connected modules is shown below.
Series Connected Remote Voltage/Current Control
Remote voltage and/or current control is possible with series connected modules using the advanced V individual control of each module can be complex as the various control terminals are referenced to the positive output of the preceding module and require the use of multiple isolated control voltages to attain control over the full voltage range. Please contact Vox Power or your distributor for assistance if remote voltage or current control is required for series connected modules.
CONTROL
and I
functions described earlier. However,
CONTROL
SELV Precautions
Where series combinations of output modules exceed 60V, the output can no longer be considered SELV (Safety Extra Low Voltage) and hence the final equipment manufacturer must provide suitable protection for both users and service personnel.
External capacitance
When large external capacitances are connected to series connected outputs, the maximum input power can be exceeded at start-up and the unit can latch off. Consider sequencing output start-up to prevent exceeding the input power limit when charging large external capacitances.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
23 | P a g e
Parallel Connected Outputs
VCCM output modules of the same type can be paralleled within the same product to achieve higher output currents. Links for paralleling modules are available directly from Vox Power or our local representatives.
The following instructions must be followed for output modules configured in this manner.
WARNING!
Energy Hazards may arise when individual modules are paralleled. See the Safety section for more details. When modules are paralleled, their inhibit lines (J3), if used, should also be paralleled. Inhibiting paralleled modules individually may cause damage
When paralleled, the outputs can operate in two distinct modes, Normal parallel mode or Share parallel mode.
Normal Parallel Mode
For normal parallel mode, the positive power cables should be connected together and the negative power cables should be connected together. No other connections are required as shown in the diagram below.
In this mode, the highest adjusted output module will supply all of the load current until its current limit is reached. If the load demand exceeds this level the output voltage will drop to the level of the next highest adjusted module and that module will begin to supply the load current while the first module continues delivering full current. This process repeats for the total number of paralleled modules. The diagram above shows the VI curve for such a system.
Output modules that are not delivering current will typically sink a small amount of current from the other outputs, but this will not exceed -6% of each module’s maximum rated current.
Typically, system reliability is reduced in this mode as the higher adjusted modules will do most of the work with the lower adjusted modules only delivering current during peak load demand.
Share Parallel Mode
In share parallel mode, the outputs are paralleled as before and the I
Connecting the I distributed evenly across all paralleled modules.
pins together forces all the outputs to deliver the same current, ensuring that the system reliability is maximised and the work load is
CONTROL
pin of each module connected together as shown in the diagram below.
CONTROL
In this mode, the lowest adjusted output module will determine the actual output voltage and all higher adjusted outputs will reduce their voltage.
The current output signal (I
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
) can still be used to measure the output current but it must be scaled by N, where N is the number of paralleled modules.
CONTROL
DOC-MN-007-03 VCCM600 User Manua l
24 | P a g e
WARNING!
Care must be taken to avoid differential voltages between the negative power output terminals of share mode paralleled modules as this can cause errors
at the control pins. To avoid this, it is recommended to use Vox Power parallel links to parallel modules in share mode.
Parallel Remote Sensing
Remote sensing can be used as normal with paralleled modules. The sense lines (S+ and S-) from each of the output modules should be connected together, S+ to S+, and S- to S- as shown below. This should be done close to the power supply output and a single pair of cables brought from these sense lines to the load. Keeping cable lengths to a minimum and using twisted pairs where necessary will help reduce noise pickup in the sense lines.
N+1 Configurations
When using N+1 redundant configurations, a suitably rated diode (or controlled MOSFET) must be used on each output to prevent a device failure from causing a system failure. However, the diode introduces voltage drops between the supply and the load that significantly degrade the load regulation. To counteract this, the remote sense lines can be used to regulate the voltage at the load as shown below.
Typically, this configuration can damage the internal sense resistors used within a power supply. However, the VCCM outputs have integrated protection to prevent this type of damage and are completely N+1 compatible without any additional external protection circuitry. Note that only the positive sense terminal is protected and diodes should be used in the positive connection only.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
25 | P a g e
Paralleled Remote Voltage/Current Adjustments
The simplest way to achieve remote voltage/current programming with paralleled outputs is to operate the modules in share parallel mode. Follow the procedure outlined earlier to configure the outputs in share parallel mode and once configured in this mode, all the V together. Remote voltage/current programming can then be performed exactly as with a stand-alone module.
It is not recommended to use remote voltage/current programming in normal parallel mode.
and COM pins can be connected
CONTROL
WARNING!
Care must be taken to avoid differential voltages between the negative power output terminals of share mode paralleled modules as this can cause errors
at the control pins. To avoid this, it is recommended to use Vox Power parallel links to parallel modules in share mode.
Paralleling Across Multiple Products
Paralleling across multiple product is not possible without external protection (such as external diodes or controlled MOSFETs) to prevent circulating currents between each product. Failure to provide such protection may result in damage to the power supplies. Consult Vox Power for details on how best to implement such applications.
When modules are paralleled across multiple products, the outputs in each product will not be synchronised and the peak to peak output ripple may contain beat frequencies in the audio spectrum.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
26 | P a g e
Mechanical Dimensions and Mounting
SCREWS
Location Details Penetration Tightening
Baseplate Mount: M1 – M6 Hole diameter = 5.00mm 4mm Baseplate thickness 0.55 NM
Output Module Mount: O1 – O8 M3 CSK M3 CSK screw, 8mm max length 0.35NM
Input module Mount: F1 – F5 Do not remove or adjust Do not remove or adjust Do not remove or adjust
Transformer module Mount: F6 – F7 M3 CSK M3 CSK screw, 6mm max length 0.35NM
Output Module Terminal M4 SEM M4 SEM screw, 8mm max length 0.55NM
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
27 | P a g e
PINOUTS
Circuit
Details
J1 –
Mains Input
J2 –
Standby control
J3 –
Global Signals
J4 -Output Signals
6 +5V (Bias Supply
1
0mA)
MATING CONNECTORS
Ref. Details
Manufacturer
Housing
Terminal
Connector details
1 Live 2 Neutral 3 Eart h
1 Standby contro l negative 2 S tandby control positive
1 Slot 4 - Power Good 2 Slot 4 - Inhibit 3 Slot 3 - Power Good 4 Slot 3 - Inhibit 5 Slot 2 - Power Good 6 Slot 2 - Inhibit 7 Slot 1 - Power Good 8 Slot 1 - Inhibit
9 Temperature sense (T 10 AC OK 11 +5V (Bias Supply 1A) 12 COM
1 - Sense
2 + Sense
3 COM
4 I Control
5 V Control
)
SNS
J1 - Mains Input 3 Pin, Barrier, 6-32 Steel Screws, 0.8 Nm or 7 Lb-In Torque
J2 - Standby control 2 Pin, 1.25mm, with Friction Lock, 28-30AWG MOLEX 0510210200 05005880 00
J3 - Global Signals
J5 - Output Signals 6 P IN, 1.25mm, with Friction Lock, 28-30AWG MOLEX 0510210600 05005880 00
Output Power Positive/Negat ive, M4 terminal, 0.55Nm, use appro priately rated crimp terminal
Notes
12 Pin, 2mm, with Friction Lock, 24-30 AW G, WIRE TO BOARD MOLEX 0511101260 05039480 51
12 Pin, 2mm, with Friction Lock, 24-30 AW G, IDT CABLE TO BOARD MOLEX 0875681273
1. Cable 14-18AWG, 300V, 16A, 105°C, use appropriately rated crimp terminal.
2. Direct equivalents may be used for any connector parts.
3. All cables must be rated 105°C min, equivalent to UL1015
(1)
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
28 | P a g e
Safety
The VCCM unit has been designed to comply with the Low Voltage Directive DIR 2014/35/EU (LVD), the EMC Directive DIR 2014/30/EU and DIR 2011/65/EU regarding the restriction of certain hazardous substances and is CE marked to show its compliance. When correctly installed (per the installation manual) in a limited access environment the VCCM600S & M comply with the requirements of EN60950 2nd Edition and EN60601 3rd Edition respectively.
The power supply should not be operated close to combustible materials or atmosphere. Care should be taken to ensure liquid or metal shavings do not enter the power supply as this can cause a fire hazard.
The power supply does not contain any user serviceable parts and should be returned to Vox Power for repair.
Approval Limitations (North America)
When this product is used with 180VAC–253VAC mains where no neutral is present, connect the two live wires to L (Live) and N (Neutral) on the input connector.
WARNING!
Series connected modules with combined voltages exceeding 60 volts are not considered SELV. Paralleled and/or series modules with
combined energy ratings greater than 240 VA may cause energy hazards. The equipment manufacturer must provide additional and adequate protection to service and technical personnel.
Always remove the power before handling the unit. During operation, the external surface of the unit can become hot. Leave to stand for 10
minutes to allow the unit to cool down before handling the unit.
Dangerous voltages are present within the power supply. Covers may only be removed by qualified personnel when the power supply has
been disconnected from the mains supply voltage for more than 2 minutes. Covers must be replaced and all screws secured properly before reconnecting to the mains voltage.
SAFETY SPECIFICATIONS
Parameter Details Max Units Notes
Isolation Voltages
Earth Leakage Current
Touch Leakage Current Standard modules NC/SFC 20/200 uA Patient Leakage Current Standard modules 264Vac, 63Hz, 25° C NC/SFC ----- uA Not applicable
Input to Output (2 MOPP) 4000 VAC Input to J2 standby control (2 MOPP) 4000 VAC Input to Chassis (1 MOPP) 1500 VAC Global signals (J3) to Output/Chassis 500 VDC Output to Output/Chassis (Standard modules) 500 VDC INDUSTRIAL: Normal condition, 264Vac, 63Hz, 25°C 1500 uA MEDICAL: Normal condition, 264Vac, 63Hz, 25°C 200 uA
INSTALLATION SPECIFICATIONS
Parameter Details Parameter Details
Equipment class I Flammability Rating Overvoltage category II Ingress prote ction rating Material Group IIIb (indoor use only) ROHS compliance Pollution degree 2 Intended usage environment
Home Healthcare (M)/ Industrial (S)
94V-2
IP10
2011/65/EU
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
29 | P a g e
EMC Compliance
To support compliance of the final system design with the EMC directive 2014/30/EU, the VCCM600 PSU has been designed and tested to the following
ELECTROMAGNETIC COMPLIANCE – EMISSIONS
Phenomenon Basic EMC Standard Test Details
Radiated emissions, electric field EN55011/22 Class B compliant Radiated emissions, electric field, 30Hz-18GHz. MIL-STD-461F: RE102 (Ground, Fixed) Compliant (When mounted in enclosure) Conducted emissions EN55011/22, FCC part 15, CISPR 22/11 Class B compliant Conducted emissions, power leads, 10kHz-1 0Mhz. MIL-STD-461F: CE102 Compliant (External filter may be required) Harmonic Distortion IEC61000-3-2 Compliant Flicker & Fluctuation IEC61000-3-3 Compliant
ELECTROMAGNETIC COMPLIANCE – IMMUNITY
Phenomenon Basic EMC Standard Test Details
Electrostatic discharge IEC61000-4-2 Test level 4: 15kV air, 8kV contact Radiated RF EM fields IEC61000-4-3 Test Level 3: (10V/m, 80MHz-2.7GHz) sine wave AM 80% 1kHz Proximity fields from RF wireless communications equipment Radiated susceptibility, electric field, 2 MHz to 40 GHz. MIL-STD-461F: RS103 20V Electrical Fast Transients/bursts IEC61000-4-4 Test Level 3: (2kV Power, 1kV I/O) 5kHz(ed3) & 100kHz(ed4) Conducted susceptibility, Bulk cable injection, impulse excitation Surges IEC61000-4-5 Test Level 3: 1kV L-N, 2kV L-E Conducted susceptibility, damped sinusoidal transients, cables and power leads, 10kHz-100MHz Shipboard Electric Power. Voltage Spike Test MIL-STD-1399, SECTION 300A Type 1, 115V 60Hz single phase Conducted disturbances induced by RF fields IEC61000-4-6 Test Level 3: 10V, 0.15 to 80Mhz sine wave AM 80% 1kHz Conducted susceptibility, power leads, 30Hz-150kHz MIL-STD-461F: CS101 Conducted susceptibility, Bulk cable injection, 10kHz­200Mhz Power Frequency Magnetic Fields IEC61000-4-8 Test level 4: 30A/m 50Hz Radiated susceptibility, Magnetic field, 30Hz-100kHz MIL-STD-461F: RS101 Voltage Dips IEC61000-4-11
Voltage Sag Immunity SEMI-F47-0706
Voltage interruptions IEC61000-4-11 0% 250/300 cycle as per IEC60601-1-2:2014 (Criterion B) Aircraft Electric Power Characteristic MIL-STD-704F SAC102,104,105,109,110 (MIL-HDBK-704-2) &
Notes:
1. Criter ion A = No degradation of performance or loss of function.
Criterion B = Temporary degra dation of performance or loss of func tion is allowed, provided the function is self-recoverable. Criterion C = Temporary loss of function is allowed but requires operator intervent ion to recover..
2. Teste d at nominal range (100V to 240V). Line deratings applied where appropriate.
standards.
IEC61000-4-3
MIL-STD-461F: CS115
MIL-STD-461F: CS116
MIL-STD-461F: CS114
(2)
0% 10ms, 0% 20ms (Criterion A)
(2)
0% 20mS, 80% 1s,80% 10s,90% continuous (Criterion A)
Test levels as per IEC60601-1-2:2014 Table 9
70% 0.5s, 40% 200mS (Criter ion A at 240V and Criterion B at 100V)
70% 0.5s, 50% 200mS (Criter ion A at 240V and Criterion B at 100V) Criterion A is achieved for full power when Vin >=160V Criterion A is achieved at all input voltages when Pout <= 350W
SXF102,104,105,109,110 (MIL-HDBK-704-6)
Typical Conducted emissions Typical Radiated emissions
For radiated and conducted emissions, compliance of the final system relies on proper installation of the PSU component. The installation guidelines detailed below should be followed.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
30 | P a g e
Installation Guidelines for optimum EMC performance
VCCM units should be mounted within a metal enclosure using the mounting fixtures provided.
If the application enclosure is not metal, then a metal ground plate should be used to mount both the power supply and the load.
Both input and output cables should be fixed as close as possible to the ground plate or metal enclosure.
Input and output cables should be separated as much as possible from each other or a shield/screen used to isolate RF currents
Output power and sense cables should be twisted pairs and routed parallel to each other. Do not twist sense and power cables together.
All cables lengths and loop areas should be minimised.
Where cables must enter or exit the enclosure, good high frequency 100nF decoupling capacitors of sufficient voltage rating should be connected to
the cables as close to the entry/exit point as possible.
For further details or assistance contact Vox Power.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
31 | P a g e
0.962972
0.398170
VCCM600M
-
AAAA 2.996363
333737.934
Temp IP XFMR OPA OPB OPC OPD VCCM600M
-
ABCD
0 0.41329578
0.127619
0.192619
0.185396
0.186105
0.186243
1.291276945
10 0.54688976
0.178886
0.245347
0.235357
0.235992
0.2362 1.678671789
Reliability
The VCCM600 series has undergone extensive testing, including HALT and Environmental testing. Reliability data is collected on an ongoing basis. Please contact Vox Power or your distributor for the most up to date reliability data.
The reliability data quoted in the datasheets are the calculated defined in SR-332 allows several different techniques to be used for calculating MTBF and when evaluating competing MTBF figures it is important that only the same techniques are compared. The quoted VCCM reliability figures use Method I Case 3, Ground, Fixed, Controlled which specifies an ambient temperature of 30°C and an upper confidence level of 90%. It is also assumed that the product is operated at 100% duty cycle, has an input voltage of 220V temperature is the same as the ambient temperature.
The table below shows a summary of the FPMH & MTBF for all system components and for a typical fully assembled system.
Assembly Failure Rate (FPMH) MTBF (Hrs) IP XFMR OPA OPB OPC OPD
To calculate the MTBF of any VCCM system,
Add the FPMH figures for each system component to give the total FPMH. Get the MTBF by dividing 1,000,000 by the total FPMH.
The variation in FPMH is shown in the graph and table below.
failures per million hours
0.371919
0.415368
0.397808
0.405630
(FPMH) using the Telcordia SR-332, issue 2 standard. The procedure
, an output power of 600W and that the baseplate
RMS
1038452 2688754 2407499 2513774 2511487 2465300
50
FPMH Vs Temperature
45
40
35
30
IP
XFMR
OPA
25
FPMH
20
15
10
OPB
OPC
OPD
VCCM600M-ABCD
5
0
0 10 20 30 40 50 60 70 80 90 100
Baseplate Temperature (°C)
20 0.72397837 0.255159 0.316147 0.302737 0.30326 0.305183 2.206465072 30 40 1.29407059 0.555049 0.560829 0.538309 0.538452 0.559393 4.046103211 50 1.76616217 0.846405 0.782692 0.754326 0.754185 0.803972 5.707742381 60 2.46010898 1.315415 1.130884 1.095712 1.095216 1.202005 8.299340054 70 3.50420104 2.067304 1.686039 1.643019 1.642101 1.855247 12.39791075 80 5.09894211 3.266645 2.575169 2.523173 2.52177 2.925702 18.91140128 90 7.55815578 5.160517 3.995269 3.93316 3.931214 4.659641 29.23795696 100 11.3495991 8.112606 6.236851 6.163284 6.160733 7.430093 45.4531658
0.96297168 0.371919 0.415369 0.397808 0.39817 0.40563 2.951868534
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
32 | P a g e
Configuring Your VCCM Product
The VCCM600 power supply is designed to be used as part of an end-system in a restricted environment and therefore should only be accessible to qualified and trained personnel. Persons attempting to configure a unit must have the necessary knowledge and training before doing so. Incorrect configuration may cause damage to the power supply and may affect the warranty of the power supply.
Output power modules may be added, replaced or moved by strictly following the sequence of operations described below. Before configuring your VCCM product, remove the VCCM600 input module and any output modules which are going to be used in the configuration from their packaging and inspect for damage.
DO NOT use parts if any part of the product exhibits any kind of physical damage. DO NOT connect any mains power before the configuration is complete.
Once configuration changes have been completed, operation of the unit should be verified and voltages can be adjusted to application requirements.
Please contact Vox Power or your distributor for assistance in configuring your power supply. Never assume, always ask.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
33 | P a g e
Adding Output Modules (A, B, C & D)
STEP 1: Each module is provided with two M3x8 Stainless Steel Posi-drive Countersunk screws at the bottom. These are used to attach the module to the baseplate. Remove these screws using the correct No1 Posi-drive screw driver.
STEP 2: Ensure that the output module base and baseplate thermal interface are both clean and free from any debris. Insert output modules as required into any one of the four available slots in the VCCM600 transformer module. Ensure the output module and transformer connectors are properly aligned and push together. There will be a solid ‘click’ once a proper connection is established. Each VCCM600 product can be configured to have up to four isolated outputs by inserting the desired output modules into the correct slots as required.
STEP 3: Once the output modules are in place, turn the entire assembly upside down and rest on a flat surface. Secure the screws which were removed in step 1 as shown below. Tighten the screws using an appropriate No1 Posi-drive screwdriver to 0.35NM.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
34 | P a g e
Removing Output Modules (Type A, B, C & D)
STEP 1: Turn the configured unit upside down and identify the slot of the module you need to remove. Remove the two screws using an appropriate No1 Posi-drive screwdriver.
STEP 2: Turn the configured unit right side up and unplug the module by pulling it away from the transformer module. To minimise stress on the connectors do not wriggle the module to remove. Take care not to damage the thermal interface material on the baseplate.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
35 | P a g e
Verifying operation after assembly
Connect the Live (L), Neutral (N) and Earth (E) terminals of the mains power cable to the corresponding terminals on the mains input connector (J1) on the VCCM600 input module. Only apply power from the mains power outlet once the connection to the VCCM600 input module has been completed. Once power has been applied, confirm that the “Power Good” indicators for all output modules are lit. If any “Power Good” indicators are not lit it may indicate a faulty output module or incorrect assembly. The mains power should be removed and the non-functioning output module re-seated or replaced.
WARNING!
Dangerous voltages are exposed on certain parts of the power supply even after power has been removed. The unit should only be handled by
qualified personnel when the power supply has been disconnected from the mains supply voltage for more than 3 minutes .
During operation, external surfaces of the unit can become hot. Appropriate precautions should be taken when handling the unit.
Adjusting output voltages
Each VCCM output module contains a built-in potentiometer to allow for accurate output voltage adjustments. To adjust the output voltage, connect a calibrated voltmeter (or DMM) to the output terminals and insert an appropriate trimming tool (e.g. Bourns Model H-90, maximum diameter 3mm) through the hole marked “Adjust” at the top of the output module as shown below. Do not use excessive force as this may damage the unit. Ensure the trimming tool mates correctly with the internal potentiometer and slowly turn the tool clockwise to increase the voltage or counter-clockwise to decrease the voltage. Once the desired voltage has been achieved, remove the trimming tool and disconnect the voltmeter. Repeat this step for each output module in need of adjustment.
Voltage Adjust
Connecting Output Modules in series
VCCM output modules of the same type can be series connected to achieve higher output voltages. Below is an illustration of how to series connect two output modules in slot 1 and slot 2 using a Vox series link. The Vox series link can be inserted by loosening the output module power terminal screws and rotating the series link into position. The screws should then be tightened to 0.5Nm. The example below shows the series connection from slot 1 negative to slot 2 positive with the output voltage taken from slot 1 positive to slot 2 negative. Further output modules can be added to the series chain by adding more series links across the remaining slots.
Energy and voltage hazards may arise when individual modules are series connected. When safe energy and voltage levels are exceeded ensure that an
appropriate warning label is affixed to the power supply in a manner that service personnel will always notice it. See the Safety section for more details.
WARNING!
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manual
36 | P a g e
T
ype 2 Heatsink
Connecting Output Modules in parallel
VCCM output modules of the same type can be paralleled in any number within the same product to achieve higher output currents. For best performance, the output voltages of each paralleled module should be pre-adjusted to within 1% of the required output voltage. It is recommended to fit Vox current share links on all paralleled output modules. Vox Power has a range of 2, 3 and 4-way current share links available. Please discuss your requirements with your distributor or with Vox Power before ordering your unit.
Below is an illustration of a mechanical connection to parallel connect two modules in slot 1 and slot 2 using Vox parallel links. Vox parallel links can be inserted by loosening the output module power terminal screws on adjacent modules and sliding the parallel link into position. The screws should then be tightened to
0.5Nm. One link is required to connect the negative power terminals and another is required to connect the positive terminals. Vox Power has a range of parallel links to connect 2, 3 or 4 output modules in parallel.
The example below shows a parallel connection from slot 1 to slot 2.
Energy and voltage hazards may arise when individual modules are paralleled. When safe energy and voltage levels are exceeded ensure that an
appropriate warning label is affixed to the power supply in a manner that service personnel will always notice it. See the Safety section for more details.
WARNING!
Attaching a heatsink or cooling plate
For improved performance, the baseplate of the VCCM600 unit can be attached to a heatsink or cooling plate. Vox Power has a range of heatsinks available to allow the VCCM600 to be mounted horizontally or vertically. Each heatsink comes pre-assembled with a high performance thermal interface pad and 6 x M4 x 10mm Pozi Pan screws which can be used to attach the heatsink to the baseplate. The diagrams below show a VCCM600 unit attachment to a Type 1 and Type 2 heatsink. Before assembly ensure both the baseplate and heatsink surfaces are clean and free from debris. The final assembly can then be mounted into the end system via the four holes (Type 1: 2 each side, Type 2: 2 each end) on the flange of the heatsink.
Type 1 Heatsink
It is recommended to tighten the baseplate mounting screws to 0.55NM. In high vibration environments, an appropriate thread lock should be used. All recommended screw tightening torques are nominal values and should be verified in the application where appropriate.
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
37 | P a g e
Accessories
Description Photo/Drawing Order code
Output Parallel
Links
2 WAY PARALLEL LINK
4 WAY SHARE CABLE
2 way – LINK-VP2 3 way = LINK-VP3 4 way = LINK-VP4
Current share
cables
Output Series
Link
Output
Quick-Connect
terminal
(6.3x0.8mm TAB x2)
Output
Cable Set
1x Signals cable
(~200mm)
2x Power terminals
2 way = CAB-CS2 3 way = CAB-CS3 4 way = CAB-CS4
LINK-VS
ACC-QCT
CAB-VSOPL
Input
Cable Set
1x Signals cable
(~200mm)
1x Standby cable
(~200mm)
3x Power terminals
CAB-VC6
DOC-MN-007-03 VCCM600 User Manual
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
38 | P a g e
Heatsink1
(Provided with 6x M4 x 10mm Posi-
Drive screws for
baseplate mounting
and thermal
interface ACC-TF)
Heatsink2
(Provided with 6x M4 x 10mm Posi-
Drive screws for
baseplate mounting
and thermal
interface ACC-TF)
ACC-HS1
ACC-HS2
Thermal
interface
(170mmx80mm)
ACC-TF
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ba llymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
DOC-MN-007-03 VCCM600 User Manua l
Loading...