NEVO+1200 Series
AC/DC MODULAR CONFIGURABLE POWER SUPPLIES
User Manual
Page 4 of 40
DOC-MN-006-03, NEVO+1200 User Manual
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
Installation Notes
This Nevo+1200 series of configurable power supplies are intended for use within end customer applications which restrict access to un-authorized personnel.
The instructions in this manual and all warning labels on the product must be adhered to carefully.
SAFETY
The NEVO+1200S and Nevo+1200M series are designed in accordance with the safety requirements of UL60950-1, EN60950-1, IEC60950-1, UL60601-1, EN606011, EN61010-1, IEC60601-1, IEC61010-1, CSA22.2 no 601-1 and the LV Directive 2014/35/EU.
All Nevo+1200 series power supplies must be installed correctly in a controlled environment which restricts access to any un-authorised personnel. Equipment
and system manufacturers must protect service personnel against unintentional contact with the output terminals.
DE-RATING
Temperature - The input module and output module power must be de-rated by 2.5%/°C above 50°C.
Input Voltage -The input module power must be de-rated by 10W/Vrms below120Vrms (1200W @ 120Vrms, 1000W @ 100Vrms, 900W @ 90Vrms)
Remember to take the appropriate de-rating into consideration before specifying any Nevo+1200 power supply for an application. If in any doubt please contact
Vox Power directly or your local Vox Power representative.
HAZZARDS
If series and/or parallel combinations of outputs exceed safe voltage and/or energy levels, the final equipment manufacturer must provide the appropriate
protection for both users and service personnel.
HEALTH AND SAFETY
To comply with section 6 of the health and safety at work act, a label that is clearly visible to service personnel must be placed on the final equipment. These
labels warn that surfaces of the power supply may be hot and should not be touched when the product is operating.
FUSING
The power supply has internal single pole fusing in the L (Live) line.
SERVICING
The power supply contains no user serviceable parts. Repairs must be carried out by authorised personnel only. Contact Vox Power for further information.
APPROVAL LIMITATIONS – NORTH AMERICA
When this product is used with 180VAC–253VAC mains where no neutral is present, connect the two live wires to L (Live) and N (Neutral) on the input connector.
COOLING
For proper cooling of the power supply, the air intake and outlet must not be impeded. Allow 50mm clearance at both ends and position cabling appropriately.
EARTH TERMINAL MARKING
To comply with the requirements of UL60950-1, EN60950-1, IEC60950-1, CSA22.2 no. 60950-1, UL60601-1, EN60601-1, EN61010-1, IEC60601-1, IEC61010-1, CSA22.2
no 601-1 where the incoming wiring earth is intended for connection as the main protective earth conductor and where the terminals for such a connection is not
supplied on a component or subassembly , the user shall add an appropriate label displaying a protective earth symbol in accordance with 60417-2-IEC-5019
directly adjacent to the terminal. The label should be durable and legible and should withstand the 15s rub test as per UL60950-1 section 1.7.15.
WARRANTY
Contact your sales agent or Vox Power for product repairs. See Vox Power standard terms and conditions for warranty conditions. Vox Power products are not
intended for use in connection with life support systems, human implantations, nuclear facilities or systems, aircraft, spacecraft, military or naval missile, ground
support or control equipment used for the purpose of guidance navigation or direction of any aircraft, spacecraft or military or naval missile or any other
application where product failure could lead to loss of life or catastrophic property damage. The user will hold Vox Power harmless from any loss, cost or
damage resulting from its breach of these provisions.
PRODUCT LABELS
The external product label contains information relevant to the power system. The label contains input voltage, maximum input current, input frequency,
maximum output power, fuse rating and type, serial number, approvals and product part number in format NEVO+1200X-ABCDEFGH-ZZZ.
NEVO OUTPUT MODULES
Each output module label contains information relevant to that particular output. The label contains voltage adjustment range, maximum output current, serial
number, approvals and the part number in format OP X.