VOV VHS-30CT Instruction Manual

EN
HEATING
CONVECTOR HEATER
Model: VHS-30CT
Instruction manual
2000W Convector heater with thermostat, fan
All the above instructions for models VHS-30CT
WALL MOUNTING
The heater is supplied with 4 off each fixing brackets, screws and plastic wall plugs to enable it to be mounted onto a wall if required. If it is decides to mount the heater on the wall, the feet should not be fitted. The position must be chosen carefully. It must not be in front of or below a power socket. It must not be below a shelf, curtains or any other obstruction. Also refer to the safety instructions overleaf. Having decided on the location of the heater it is necessary to drill 2 fixing holes 8mm diameter by 43mm deep at 486mm centers on a horizontal line at a minimum height of 400mm from the floor. Allowance must be made for any floor coverings, carpet etc. and if any skirting boards are present, the fixing holes must be a minimum of 400mm above the top edge of the skirting board. Using the plastic plugs and fixing screws provided, attach 2 of the fixing brackets to the wall. The other pair of fixing brackets must be attached to the base of the heater using the feet retaining screws so that the brackets project out at the rear of the heater and space the bottom edge away from the wall. If required, these brackets may also be secured to the wall using the remaining fixing screws and plastic wall plugs. If this option is chosen it is suggested that the heater is hung on the upper brackets and the hole positions for the lower brackets is then marked on the wall, prior to drilling the holes for attachment purposes.
CLEANING THE HEATER
Always un-plug the heater from the wall socket and allow it to cool down before cleaning. Clean the outside of the heater by wiping with a damp cloth and buff with a dry cloth. Do not use any detergents or abrasives and do not allow any water to enter the heater.
STORING THE HEATER
When the heater is not used for long periods of time it should be protected from dust and stored in a clean dry place.
TECHNICAL CHARACTERISTICS
VHS-30CT – Convector heater with thermostat and fan. MAX. POWER: 2000-2200W POWER RANGE: 750-1250-2000W MOTOR POWER: 20W VOLTAGE: 230V~50Hz
IMPORTANT Read these instructions fully before using the heater. Retain these instructions for future reference.
ASSEMBLY OF THE HEATER
Before using the heater, the feet (supplied separately in the carton), must be fitted to the unit. These are to be attached to the base of the heater using that they are located correctly in the bottom ends of the heater side moldings.
SAFETY INSTRUCTIONS (to be read before operating the heater)
Do not use the heater unless the feet are correctly attached. Ensure the power supply to the socket into which the heater is in accordance with the rating label on the heater and that the socket is earthed. Keep the mains lead away from the hot body of the heater. The heater is not intended for use in bathrooms, laundry areas or similar indoor locations. Never place the heater where it may fall into a bathtub or other water container. Do not use outdoors. Do not cover or obstruct any of the heat outlet grilles or the air intake openings of the heater. Do not place the heater on carpets having a very deep pile. Always ensure that the heater is placed on a firm level surface. Ensure that the heater is not positioned close to curtains or furniture as this could create a fire hazard. Do not position the heater in front of, or immediately below, a wall socket. Do not insert the heater in areas where flammable liquids are stored or where flammable fumes may be present. Particular care should be taken when the heater is situated in areas occupied by children or invalids. Always unplug the heater when moving it from one location to another. Do not use the heater if the power cord is damaged. If the power cord is damaged it must be replaced by a recognized service agent or other qualified person. If the plug is damaged, see Plug Replacement details below.
OPERATION OF THE HEATER
NOTE: It is normal when the heaters are turned on for the first time or when they are turned on after having not been used for a long period of time the heaters may emit some smell and fumes. This will disappear when the heater has been on a short while.
Choose a suitable location for the heater, taking into account the safety instructions above. Insert the plug of the heater into a suitable socket. Turn the thermostat knob fully in a clockwise direction to the maximum setting.
Turn on the heating elements by means of the rocker switches on the side panel. When the heating elements are on the switches will illuminate. For maximum heat output both switches should be on. When the desired room temperature has been reached, the thermostat knob should be turned slowly anti-clockwise until the thermostat is heard to click off and the lights on the element switches are seen to go out. After this the heater will keep the air temperature in the room at the set temperature by switching on and off automatically. In it is minimum (fully anti-clockwise) position, the thermostat provides a frost guard position. In this position (depending on the size of the room) the heater will maintain the temperature above freezing.
It also incorporates an internal fan, which can be switched on independently of the heating elements. Fan Operation: This is operated by means of the switch with the fan symbol along side it. The fan will only operate with the thermostat in the “ON” position and can be used when the heating elements are “ON” to blow warm air into the room. In warm conditions the fan can be used with the heating elements “OFF” to blow cool air into the room.
According to Waste of Electrical and Electronic Equipment (WEEE) directive, WEEE should be separately collected and treated. If at any time in future you need to dispose of this product please do NOT dispose of this product with household waste. Please send this product to WEEE collecting points where available.