- 3 -
Connection (q.v. Fig 5, Connection Plan):
Configuration of Connections Tank Probe:
1 = Battery „-„ (Minus) or Body Ground (0.5 - 1.0 mm²)
4 = Tank Pulse to the Display Unit Connection 4 (0.5 - 1.0 mm²)
5 = Tank „+“ to the Display Unit Connection 5 (0.5 - 1.0 mm²)
A = Conductor Stainless Steel Screw at the Tank Bottom
S = Probe measuring line, highly flexible, being suspended in the
tank
The VOTRONIC Tank Sensor FL is completely protected against wrong
polarization. It is, however, recommendable to use connection cables of
different colours to avoid malfunctions due to mixed up connections.
Start-up and Adjustment:
A setting screw being located at the terminal side of the electronic module
can be used for the adjustment "Full" to the conditions of the tank. The
range of action of this setting screw is 25 rotations. It does not have a limit stop, so "overwinding" is excluded.
1. Fill the tank until the reserve level is reached (fig. 1 and fig. 2).
2. Turn the adjuster "Full" until "100 %" will be displayed on the display panel without problems.
The adjustment procedure is completed. The functions of the display can now be simulated with several water levels
in the tank or by withdrawing the probe cable out of the full tank.
Final Installation:
In case of underfloor installation of the tank, the electric connections (terminal screws), the input of the
probe screwing and the setting screw at the tank sensor FL have to be protected against environmental
pollution by means of sealant. We recommend to also protecting the conductor (cable lug, stainless steel
screw). Use a permanently elastic sealant (e. g. "Sikaflex") for protection.
Neither use silicone separating acetic acid in connection with metal, nor resisting agent containing carbon! The above-
mentioned sealant has been proved to be very suitable in practice.
Tips & Tricks:
No reaction of display:
a.) Cable "4 = Tank Pulse" withdraw connector by way of trial: The display should increase to "100 %".
b.) Battery connection or fuse defective - check
c.) Cable „5 = Tank Pulse“ interrupted - check
d.) Cable „4 = Tank Pulse“: Short-circuit to ground - check
e.) Conductor does not have any contact with liquid - check
Constant display of 100 % on the display unit:
a.) Cable "4 = Tank Pulse" withdraw it and direct it to ground: No display
b.) Cable „4 = Tank Pulse“ interrupted – check
c.) Cable "1 = Battery Minus/Ground" is interrupted or does not have any contact at the body sheet - check
d.) Contact of the insulated probe with water (silicone cap leaky or dropped off, damaged insulation) – check
Indication Errors:
a.) In case of underfloor installation of the tank and insufficient protection of the electric connections (humidity,
soiling, de-icing salt) - clean and seal
b.) Intense soiling and furring of the probe (formation of algae in the fresh water tank, "stuck" solids in the sewage
water tank and feces tank) - clean tank