Vornado ULTRA3 User Manual

READ AND SAVE THESE INSTRUCTIONS
Ultrasonic Vortex Humidifier Owner’s Guide
LEER Y GUARDAR ESTAS INSTRUCCIONES
Guía para el usuario
LISEZ ET CONSERVEZ CES INSTRUCTIONS
Manuel d’utilisation
www.vornado.com
model ULTRA3
Pensado, diseñado y respaldado en Andover, Kansas.
Conception, mise au point et soutien technique effectués à Andover, au Kansas.
Questions or comments?
¿
Prequntas o comentarios? Questions ou commentaires?
www.vornado.com
consumerservice@vornado.com
800.234.0604
Important Instructions ....................................................... 4
The Vornado Difference ..................................................... 5
Product Information ........................................................... 6
Contents
Unpacking Your Humidifier
Remove your Humidifier from carton by lifting from bottom of unit. Lifting by recessed handle on Water Tank, may cause Tank to detach and unit to fall and cause damage.
Getting Started
Filling Water Tank ............................................................ 8
How to Use Humidifier Controls ........................................ 9
Cleaning and Maintenance
Cleaning Instructions ...................................................... 10
Mineral Cartridge Replacement ..................................... 11
Operating Tips and Recommendations ............................. 12
Automatic Filter Refill Program ......................................... 12
Storage ............................................................................... 12
Troubleshooting ................................................................. 13
Warranty ............................................................................. 14
We recommend checking the Base and Water Tank for leaks that may have occurred due to damage caused in shipping. Please note a visual inspection may not reveal hairline fractures.
To Check for Leaks:
Place Humidifier on a water-resistant surface. Fill Water Tank and Base with water to inspect for leaks (For instructions see FILLING WATER TANK.)
Not Leaking?
Empty water from Base and install full Water TANK (For instructions see FILLING WATER TANK.)
Leaking?
In the remote chance your Humidifier has leaks, contact Vornado Consumer Services and we will immediately replace damaged parts.
Español p. 15 Français p. 27
English 3
Important Instructions
READ AND SAVE ALL INSTRUCTIONS BEFORE USING THIS HUMIDIFIER.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock and injury to persons, including the following:
Read all instructions before using this Humidifier. This Humidifier may not work properly on an uneven surface. Always place this Humidifier on a firm, flat surface. This Humidifier requires periodic cleaning. Refer to the CLEANING instructions provided. Never clean the Humidifier in any manner other than as instructed in this manual. Turn the Humidifier off if the relative humidity exceeds 60%. Humidity levels above 60% may allow moisture to build up indoors and condense on surfaces, where bacteria and fungi can settle and grow. For accurate humidity readings, use a hygrometer which is available at most hardware stores and home centers. Unplug the Humidifier prior to moving, cleaning or refilling. This Humidifier should always be unplugged and emptied when not in operation. This product is equipped with a polarized alternating current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a SAFETY FEATURE. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug still fails to fit, contact an electrician to replace the obsolete outlet. DO NOT defeat the safety purpose of the polarized plug. DO NOT operate the Humidifier with a damaged cord or plug, after the Humidifier malfunctions, or has been dropped or damaged in any manner. Return to Vornado for examination, electrical or mechanical adjustment or repair.
4 English
DO NOT run power cord under carpeting. DO NOT cover cord with throw rugs, runners or similar objects. Arrange the power cord away from traffic areas, so it will not become a tripping hazard. DO NOT place the Humidifier near heat sources such as stoves, radiators or heaters. DO NOT run unit without the Mist Outlet in place. The Mist Outlet can be removed for cleaning. Never pour water through the top Outlet Air Grill on the Power Head. If the Humidifier is to be turned off and left for more than 12 hours, the water should be emptied from the unit, as leaving the water will encourage the growth of algae or bacteria. If this happens, thoroughly clean and disinfect the unit. (Refer to the CLEANING instructions.) If you need to move the Humidifier to another location, remove the Water Reservoir first. Use only water and mild detergents to perform daily maintenance on your Humidifier. Do not use undiluted bleach or ammonia, strong detergents, abrasive cleansers, gasoline, paint thinner or other solvents to clean this Humidifier. The Power Head contains no user serviceable parts. If you experience a problem, please see the warranty for information. DO NOT ATTEMPT TO DISASSEMBLE THE POWER HEAD. DOING SO WILL VOID YOUR WARRANTY AND COULD CAUSE DAMAGE AND/OR PERSONAL INJURY. DO NOT repeatedly remove and replace the Water Reservoir. This will only fill the Base and water will spill out.
SAVE THESE INSTRUCTIONS
Trust.
It is said that trust isn’t given, but earned. For decades Vornado has been earning the trust of our customers by offering them only the best. Vornado provides the highest level of performance, coupled with the highest level of support available. Complete satisfaction with no exceptions – this is Vornado’s promise to you. If you are not satisfied for any reason, please contact us. Knowledgeable repre­sentatives are available at 1-800-234-0604 from 7:00 AM to 6:00 PM CST. A wealth of additional support is also available online at www.vornado.com. On behalf of myself and the entire staff at our Andover, Kansas headquarters – thank you for selecting Vornado.
Sincerely, Bill Phillips CEO, Vornado Air
Find our complete product line at www.vornado.com
The Vornado Difference
See it
in action
ULTRA3 HUMIDIFIER
Without adequate circulation With Vornado Vortex Action
Unlike any other ultrasonic humidifier, Vornado delivers whole room humidification using our exclusive Vortex Action. The Vornado Ultrasonic channels mist into a powerful beam of air and evenly dis­tributes the humidity throughout the living area. Other systems are only designed to push mist out of the unit, once outside, there is no mechanism to deliver the humidity throughout the living space. The mist simply falls, leaving the floor damp.
ULTRA3 HUMIDIFIER
English 5
Product Information
1
Push Button Controls
Easily adjust set Humidity level: 40% - 60% or Continuous and Output - High, Low, or Auto.
Mist Outlet
2
Moist air is dispersed through the Mist Outlet and projected into Vornado’s signature Vortex beam of air - circulating the moist air throughout the entire room.
3
Base
Durable, leak-resistant construction.
4
Water Tank
Large 1 gallon capacity allows for fewer refills.
Mineral Cartridge
5
Removes minerals from the water, thereby softening the water and reducing harmful mineral buildup on the Transducer.
Gasket
6
Creates a waterproof seal between Cap and Water Tank.
Cap
7
Easy-to-remove Cap for convenient Water Tank refilling.
Power Cord
8
Convenient 6 ft. cord.
9
Fill Port
Releases water from Water Tank into Base.
10
Ultrasonic Transducer
Rapid vibrations break water into a fine mist.
11
Cleaning Brush
Used for cleaning the Base in hard to reach areas. Stored in Base.
Item ...................................................................... HU1-0031-06
Model .............................................................................. ULTRA3
Warranty ................................................................ 5 Year Limited
6 English
Mineral Cartridge ........................................................ MD1-0021
2
1
4
11
10
9
3
5
7
6
8
English 7
Getting Started
Filling Water Tank
Before initial use, you must soak the Mineral Cartridge in water for 24 hours. You may use a separate container or Water Tank to do so. If Tank is used, empty water and refill with fresh water prior to use. Note: the unit may take several minutes to create mist with the initial use of a new Mineral Cartridge.
This Humidifier has a 1 gallon capacity and 2 gallon output in 24 hours (if set to High Output, Continuous Humidity setting).
To fill Water Tank:
Unplug Humidifier. Place on firm and level surface, such as the
1.
floor. Note: Spills can occur during cleaning, moving, or refilling Water Tank, so be careful to avoid spills when doing these activities. Do not touch the water inside the Base, as the water temperature can reach 92 degrees F. Remove Water Tank by grasping recessed handle on back (A).
2.
Pull outward and lift. Turn Water Tank upside down.
3.
Remove Cap (B). Empty any remaining water inside Water Tank.
4.
Rinse, wipe clean and dry with clean cloth or paper towel. Place Water Tank in sink with opening at the top.
5.
Fill Water Tank with cool tap water (C).
6.
Ensure Gasket is properly positioned and secure Cap.
7.
Lower Water Tank into Base, positioning Fill Port over raised
8.
bump in Base. Once in nested position, the water outlet valve inside Cap will open, releasing water into Base.
8 English
A
B
Note: The rate of water dispensing from Water Tank into Base is controlled by the Mineral Cartridge. The unit may take several minutes to fill the Base.
C
How to Use Humidifier Controls
Read and understand this owners guide before operating this product. Position unit to not blow directly on objects or plants. Plug unit into a 110-120 volt AC outlet.
Power Button (A) - turns the unit On or Off. LED light will illuminate when powered On. Unit will default to High Output and Continuous Humidity setting. Adjust settings for desired operation.
Output Button (B) - adjusts fan speed and mist output. Select High, Low, or Auto. High - high mist output and high fan speed for fast humidification for larger rooms. High speed operation will evaporate 2 gallons of water (+/- 10%) in 24 hours of continuous operation. (This assumes room conditions of 70º F and 30% relative humidity.) Low - low mist output and low fan speed operation for quiet, nighttime use or smaller rooms. On Low operation, your Humidifier may run without refilling for extended periods.
Auto - operation for more precise humidity control. Fan speed and mist output will fluctuate to better maintain set humidity level with the minimal amount of fan noise.
Humidity Button (C) - sets desired humidity level. Select 40% - 60% or Continuous. Press Humidity Button until desired humidification level is illuminated. The unit will operate until the desired humidity level is reached, at this point, the mist will turn Off. The humidity level indicator light will remain on. If the mist does not turn on, the set humidity level may be lower than the room humidity level. Increase the humidity set point until the mist turns on. This is an indication of the level of humidity already in the room. If moisture forms on walls or windows, lower humidity settings or turn Off Humidifier.
English 9
Cleaning and Maintenance
Cleaning Instructions
Proper cleaning of your Ultrasonic Vortex Humidifier is essential to the air quality and performance of your unit. The frequency in which your Humidifier will need to be cleaned will vary, depending on use, water hardness, and outside environmental factors. It is recommended, assuming average use, to thouroughly clean the unit several times throughout the season, or when algae, mineral deposits or other particles begin to form. To clean your Humidifier, follow these instructions:
1.
Turn the Humidifier Off and unplug. Do not submerge into water. Remove Mist Outlet by grasping base of Outlet and pulling up (A).
A
B
3.
Fill Base and Water Tank with a mixture of water and white vinegar ­mixed at a ratio of one (1) 8 oz. cup of undiluted white vinegar per 1 gallon of water (C). Do not overfill, discard unused portion. Solution should remain in Base and Water Tank for 20 minutes to dissolve any residue.
C
2.
Empty water from Base and Water Tank. (See FILLING WATER TANK for instructions). Place Mist Outlet inside Water Tank to clean both components at the same time (B). Note: Do not operate the unit during cleaning.
10 English
8 oz.
White Vinegar
4.
Empty after 20 minutes and clean Mist Outlet and all interior surfaces of Base and Water Tank with soft brush. Dampen soft cloth with undiluted white vinegar and wipe down to remove scale. Rinse thoroughly with clean warm water before disinfecting.
+
1 gal.
Water
To Disinfect:
1.
Place Mist Outlet back into Water Tank.
2.
Fill Base and Water Tank with a mixture of water and chlorine bleach - mixed at a ratio of one (1) teaspoon of chlorine bleach per 1 gallon of water (D). Do not overfill, discard unused portion. Solution should remain in Base and Water Tank for 20 minutes to fully disinfect.
D
1 tsp.
Chlorine Bleach
+
1 gal.
Water
Cleaning and Maintenance
months. The Cartridge will need to be replaced earlier if white powder residue accumulates around the device. If the water used in the humidifier has been treated by a decalcification system, the salt from the treatment can show up as white dust also.
How to Replace:
1.
Remove Water Tank (See FILLING WATER TANK for instructions)
2.
Unscrew Cap.
3.
Unscrew Mineral Cartridge from Cap (A). Discard Cartridge.
A
3.
Rinse with water until bleach smell is gone. Dry with clean cloth or paper towel.
4.
Reinstall all components. Components must be securely in place for unit to function properly.
Mineral Cartridge Replacement
The Mineral Cartridge removes minerals from the water thereby softening the water and and reducing harmful mineral buildup on the Transducer.
When to Replace: Many factors affect the frequency in which the Cartridge will need to be replaced - including amount of use, water hardness, and outside environmental factors. For heavy use, using the unit continuously, we recommend replacing the Cartridge approximately once a month. For lighter use, using the unit intermittently, we recommend replacing the Cartridge every two
MINERAL CARTRIDGE
View cartridge replacement tutorial on your mobile device.
4.
Install new Cartridge onto Cap.
5.
If continuing use of Humidifier, fill Water Tank and reinstall Cap. Replace Tank back into unit. Your Humidifier is now ready for use. Note: the unit may take several minutes to create mist with the initial use of a new Mineral Cartridge.
6.
If storing unit, empty Water Tank and reinstall Cap. Replace Tank back into unit. See STORAGE for instructions.
MINERAL CARTRIDGE
English 11
Operating Tips and Recommendations
For best results:
1. Allow for optimum airflow by keeping the mist outlet and grill unobstructed. Ensure curtains and other items are far enough away from the unit to not be pulled into the side inlets or inter­fere with airflow.
2. Operate your Humidifier continuously. This will help maintain the desired humidity level in your home, cost only pennies a day, and will not damage the unit.
It is normal and expected for your Humidifier to run continuously for a few days in order to raise the moisture content of the air to the desired level upon initial use or if the air is extremely dry. When your home and its furnishings have absorbed sufficient moisture and become stabilized at the desired humidity level, the amount of water used will decrease. If you operate your Humidifier continuously, it may need to be refilled with water every day. Simply look through the Water Tank to be certain that there is adequate water supply for operation. When the water level drops below the operating level, the misting function will stop. Any additives such as aroma fragrances or water conditioners must not be used. Any use of such additives will void the manufacturer’s warranty. These additives can cause cracks in the plastic of the Humidifier and may affect Transducer performance. Protect the Water Tank from damage. Any cracks or damage to the Tank may cause it to leak water onto the floor or other surfaces. If the Humidifier is turned Off, with water in the unit, and not turned back on for 12 hours or longer, or if the unit is not cleaned as recommended, you may experience some growth of algae or bacteria. These microorganisms may become airborne. Thoroughly clean the unit to eliminate any microorganisms (See
12 English
CLEANING AND MAINTENANCE for instructions). Your Ultrasonic Vortex Humidifier is effective at supplying necessary moisture to dry air. It should be used with proper care to prevent over-humidification. To know if the humidity level is too high, gauge the condensation or frost on windows. Adjust your Humidifier to a point where this condition is at a minimum.
Storage
1. Thoroughly clean unit (See CLEANING INSTRUCTIONS).
2. Remove and discard Mineral Cartridge (See MINERAL
CARTRIDGE REPLACEMENT). Be sure to buy a new Mineral Cartridge now so you are ready for next season!
3. Empty Water Tank and Base. Let unit dry completely.
4. Place in original retail carton if available.
5. Your Humidifier is now ready for Storage. Store in a cool, dry
location.
Note: It is recommended to clean the unit again before use.
Automatic Refill Program
Select the shipment interval and Vornado will send replacement Mineral Cartridges auto­matically. Eliminate the hassle of remember­ing to reorder. Maintain the high efficiency of your Vornado Humidifier. To sign up, visit www.vornado.com, email consumerservice@vornado.com or call 1-800­234-0604. Cancel at anytime.
Part # MD1-0021
Loading...
+ 28 hidden pages