Important Instructions ....................................................... 4
The Vornado Difference ..................................................... 5
Product Information ........................................................... 6
Contents
Unpacking Your Humidifier
Remove your Humidifier from carton by lifting from bottom of
unit. Lifting by recessed handle on Water Tank, may cause Tank
to detach and unit to fall and cause damage.
Designed, engineered and supported in Andover, Kansas.
Pensado, diseñado y respaldado en Andover, Kansas.
Conception, mise au point et soutien technique effectués à Andover, au Kansas.
Questions or comments?
¿
Prequntas o comentarios?
Questions ou commentaires?
www.vornado.com
consumerservice@vornado.com
800.234.0604
Getting Started
Filling Water Tank ............................................................ 8
How to Use Humidifier Controls ........................................ 9
We recommend checking the Base and Water Tank for leaks that
may have occurred due to damage caused in shipping. Please
note a visual inspection may not reveal hairline fractures.
To Check for Leaks:
Place Humidifier on a water-resistant surface.
Fill Water Tank and Base with water to inspect for leaks (For
instructions see FILLING WATER TANK.)
Not Leaking?
Empty water from Base and install full Water Tank (For
instructions see FILLING WATER TANK.)
Leaking?
In the remote chance your Humidifier has leaks, contact Vornado
Consumer Services and we will immediately replace damaged
parts.
Español p. 15
Français p. 27
English 3
IMPORTANT INSTRUCTIONS
READ AND SAVE ALL INSTRUCTIONS BEFORE USING THIS HEATER.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock and injury to
persons, including the following:
DO read all instructions before using this Humidifier.
DO turn the Humidifier off if the relative humidity exceeds 60%. Humidity
levels above 60% may allow moisture to build up indoors and condense on
surfaces, where microorganisms can settle and grow. For accurate humidity
readings, use a hygrometer which is available at most hardware stores and
home centers.
DO unplug the Humidifier prior to moving, cleaning or refilling.
DO unplug and empty this Humidifier when not in operation.
DO empty water from the unit if the Humidifier is to be turned off and left
for more than 12 hours, as leaving the water will encourage the growth of
microorganisms. If this happens, thoroughly clean and disinfect the unit.
(Refer to the WEEKLY MAINTENANCE.)
DO remove the Water Tank first if you need to move the Humidifier to
another location.
This Humidifier requires periodic cleaning. Refer to the WEEKLY
MAINTENANCE instructions provided. DO NOT clean the Humidifier in
any manner other than as instructed in this manual.
DO NOT use this Humidifier on an uneven surface. Always place this
Humidifier on a firm, flat surface.
DO NOT defeat the safety purpose of the polarized plug. This product is
equipped with a polarized alternating current line plug (a plug having one
blade wider than the other). This plug will fit into the power outlet only one
way. This is a SAFETY FEATURE. If you are unable to insert the plug fully
into the outlet, try reversing the plug. If the plug still fails to fit, contact an
electrician to replace the obsolete outlet.
DO NOT operate the Humidifier with a damaged cord or plug, after the
Humidifier malfunctions, or has been dropped or damaged in any manner.
4 EnglishEnglish 5
Return to Vornado for examination, electrical or mechanical adjustment or
repair.
DO NOT run power cord under carpeting.
DO NOT cover cord with throw rugs, runners or similar objects. Arrange
the power cord away from traffic areas, so it will not become a tripping
hazard.
DO NOT place the Humidifier near heat sources such as stoves, radiators
or heaters.
DO NOT pour water through the top Outlet Air Grill on the Power Head.
DO NOT use undiluted bleach or ammonia, strong detergents, abrasive
cleansers, gasoline, paint thinner or other solvents to clean this Humidifier.
Use only water and mild detergents to perform daily maintenance on your
Humidifier.
DO NOT ATTEMPT TO DISASSEMBLE THE POWER HEAD. DOING SO
WILL VOID YOUR WARRANTY AND COULD CAUSE DAMAGE AND/OR
PERSONAL INJURY. The Power Head contains no user serviceable parts. If
you experience a problem, please see the limited warranty for information.
DO NOT repeatedly remove and replace the Water Tank. This will only fill
the Base and water will spill out.
Humidifiers should be kept away from children and not be placed in a
child’s room without supervision.
See page 5 for parts listing and identification.
If you have any questions regarding this product, please call
Vornado Consumer Service, toll-free at 1-800-234-0604, or
consumerservice@vornado.com.
SAVE THESE INSTRUCTIONS
Trust.
It is said that trust isn’t given, but earned. For decades Vornado has
been earning the trust of our customers by offering them only the
best. Vornado provides the highest level of performance, coupled
with the highest level of support available. Complete satisfaction
with no exceptions – this is Vornado’s promise to you. If you are not
satisfied for any reason, please contact us. Knowledgeable representatives are available at 1-800-234-0604 from 7:00 AM to 6:00 PM
CST. A wealth of additional support is also available online at
www.vornado.com. On behalf of myself and the entire staff at our
Andover, Kansas headquarters – thank you for selecting Vornado.
Sincerely,
Bill Phillips
CEO, Vornado Air
Find our complete product line at www.vornado.com
The Vornado Difference
See it
in action
EVAP HUMIDIFIER
Without adequate circulationWith Vornado Vortex Action
The Vornado Vortex assisted humidifier distributes moisture
farther into the room, enabling faster humidification.
By incorporating Vornado’s exclusive Vortex Action, the humidifier
moves large volumes of harsh, dry air through two
specially designed filters and circulates the moistened air through-
out the room, providing complete and even humidification.
EVAP HUMIDIFIER
Product Information
Product Information
1
Control Panel
Easily adjust Fan Settings and set Humidity level: 35% - 60% or
Continuous.
Power Head
2
Powerful motor circulates moist air throughout the whole room.
Air Outlet Grill
3
Initiates Vornado's signature Vortex circulation.
Humidistat
4
Reads humidity in the room for automatic humidity control.
5
2 Vornado Evaporative Filters
Wick up water.
6
Inlet Grills
Designed for efficient air intake.
7
Base
Durable, leak-resistant construction.
Water Tank
8
Large 1.5 gallon capacity allows for fewer refills.
Gasket
9
Creates a waterproof seal between Cap and Water Tank.
Cap
10
Easy-to-remove Cap for convenient Water Tank refilling.
This Humidifier has a 1.5 gallon capacity and 2.6 gallon output in 24
hours (if set to High Fan Speed, Continuous Humidity setting).
To fill Water Tank:
1.
Unplug Humidifier. Place on firm and level surface, such as the
floor.
Note: Spills can occur during cleaning, moving, or refilling
Water Tank, so be careful to avoid spills when doing these
activities.
2.
Remove Water Tank by grasping recessed handle on top (A). Pull
outward and lift (B).
3.
Turn Water Tank upside down.
4.
Remove Cap (C). Empty any remaining water inside Water Tank.
Rinse, wipe clean and dry with clean cloth or paper towel.
5.
Place Water Tank in sink with opening at the top.
6.
Fill Water Tank with cool tap water (D).
7.
Ensure Gasket is properly positioned and secure Cap.
8.
Lower Water Tank into Base, positioning Fill Port over raised
bump in Base. Once in nested position, the water outlet valve
inside Cap will open, releasing water into Base.
8 EnglishEnglish 9
Read and understand this owners guide before operating this product.
Position unit to not blow directly on objects or plants. Plug unit into a
110-120 volt AC outlet.
Power Button (A) - turns the unit On or Off. LED indicator lights will
illuminate default settings when powered On. Unit will default to
High Fan Speed, Continuous Humidity.
Fan Setting Button (B) - select desired Fan Setting. On the EVAP3
select - Low, High or Auto. On the EVAP1 select - Low (I), Medium (II) or
High (III).
Low or (I) - operation for quiet, nighttime use or smaller rooms. On
Low operation, your Humidifier may run without refilling for extended
periods.
Medium or (II), EVAP1 Only - operation for normal use.
High or (III) - operation for fast humidification for larger rooms. High
8 | English
speed operation will evaporate 2.6 gallons of water (+/- 10%) in 24
hours of continuous operation. (This assumes room conditions of 70º F
and 30% relative humidity.)
Auto, EVAP3 Only - operation for more precise humidity control. Fan
speed will fluctuate to better maintain set humidity level with the
minimal amount of fan noise.
Humidity Button (C) - sets desired humidity level. Press Humidity
Button until desired humidification level is illuminated, 35% - 60% or
Continuous. The unit will operate until the desired humidity level is
reached, at this point, the fan will turn Off and the fan speed indicator
light will turn Off. The humidity level indicator light will remain On. If
the fan does not turn on, the set humidity level may be lower than the
room humidity level. Increase the humidity set point until the fan turns
On. This is an indication of the level of humidity already in the room.
If moisture forms on walls or windows, lower humidity settings or turn
Off Humidifier.
EVAP3 Pictured
Cleaning and Maintenance
Filter Replacement
The Filters may accumulate minerals and other impurities that occur
naturally in any water supply. While your Humidifier came equipped
with two Filters, you will eventually have to replace them.
How to Replace:
1.
Turn the unit off and unplug. Remove Power Head (A).
A
EVAP1 EVAP3 MAINT
View filter
replacement tutorial on
your mobile device.
EVAP1 EVAP3 MAINT
2.
Remove and discard used Filters (B).
B
When to Replace: Many factors affect the frequency in which
the Filters will need to be replaced - including amount of use,
water hardness, and outside environmental factors. For heavy
use, using the unit continuously, we recommend replacing the
Filters approximately once a month. For lighter use, using the
unit intermittently, we recommend replacing the Filters every two
months.
3.
The Filters will need to be replaced earlier if the Filters become
hard or are no longer absorbing the water effectively. Replace
Filters with only genuine Vornado® brand Filters. While other
brands may fit our units, these Filters do not carry the same quality
and life as our own and can diminish the Humidifier’s performance.
10 EnglishEnglish 11
Install new genuine Vornado Filters by making sure they are flush
against the sides of the unit and touching the bottom of the Base.
4.
Replace Power Head. Your Humidifier is now ready for use.
Cleaning Instructions
Proper cleaning of your Evaporative Vortex Humidifier is essential
to the air quality and performance of your unit. The frequency in
which your Humidifier will need to be cleaned will vary, depending
on use, water hardness, and outside environmental factors. It is
recommended, assuming average use, to thouroughly clean the unit
several times throughout the season, or when algae, mineral deposits
or other particles begin to form.
To clean:
1.
Turn the Humidifier Off and unplug. Do not submerge in water.
2.
Remove Power Head and Filters (See FILTER REPLACEMENT for
instructions).
3.
Remove Water Tank and Inlet Grill. To remove Inlet Grill, undo the
latch (A) and lift (B).
AB
4.
Empty water from Base and Water Tank. (See FILLING WATER
TANK for instructions).
Note: Do not operate the unit during cleaning.
5.
Fill Base and Water Tank with a mixture of water and white vinegar
- mixed at a ratio of one (1) 8 oz. cup of undiluted white vinegar
per 1 gallon of water (C). Do not overfill, discard unused portion.
Solution should remain in Base and Water Tank for 20 minutes to
dissolve any residue.
Cleaning and Maintenance
C
8 oz.
White Vinegar
Empty after 20 minutes and clean all interior surfaces of Base and
6.
Water Tank with soft brush. Dampen soft cloth with undiluted white
vinegar and wipe down to remove scale.
Rinse thoroughly with clean warm water before disinfecting.
7.
To Disinfect:
Fill Base and Water Tank with a mixture of water and chlorine
1.
bleach - mixed at a ratio of one (1) teaspoon of chlorine bleach
per 1 gallon of water (D). Do not overfill, discard unused portion.
Solution should remain in Base and Water Tank for 20 minutes to
fully disinfect.
+
D
1 tsp.
Chlorine Bleach
Rinse with water until bleach smell is gone. Dry with clean cloth or
2.
paper towel.
Reinstall all components. Components must be securely in place for
3.
unit to function properly.
+
1 gal.
Water
1 gal.
Water
Operating Tips and RecommendationsTroubleshooting
For best results:
1. Allow for optimum airflow by keeping the grill unobstructed.
Ensure curtains and other items are far enough away from the
unit to not be pulled into the side inlets or interfere with airflow.
2. Do not turn the unit off and on - allow your Humidifier to
operate continuously. This will help maintain the desired
humidity level in your home, cost only pennies a day, and will
not damage the unit.
It is normal and expected for your Humidifier to run continuously
for a few days in order to raise the moisture content of the air
to the desired level upon initial use or if the air is extremely dry.
When your home and its furnishings have absorbed sufficient
moisture and become stabilized at the desired humidity level, the
amount of water used will decrease.
If you operate your Humidifier continuously, it may need to be
refilled with water every day. Simply look through the Water Tank
to be certain that there is adequate water supply for operation.
When the water level drops below the operating level, the unit will
not be producing humidity.
Protect the Water Tank from damage. Any cracks or damage to the
Tank may cause it to leak water onto the floor or other surfaces.
If the Humidifier is turned Off, with water in the unit, and not
turned back on for 8 hours or longer, or if the unit is not cleaned
as recommended, you may experience some growth of algae
or bacteria. These microorganisms may become airborne.
Thoroughly clean the unit to eliminate any microorganisms (See
CLEANING AND MAINTENANCE for instructions).
Your Evaporative Vortex Humidifier is effective at supplying
necessary moisture to dry air. It should be used with proper care
to prevent over-humidification. To know if the humidity level is too
12 EnglishEnglish 13
high, gauge the condensation or frost on windows. Adjust your
Humidifier to a point where this condition is at a minimum.
Storage
1. Thoroughly clean unit (See CLEANING INSTRUCTIONS).
2. Remove and discard used Filters (See FILTER REPLACEMENT).
Be sure to buy a new Filters now so you are ready for next
season!
3. Empty Water Tank and Base. Let unit dry completely.
4. Place in original retail carton if available.
5. Your Humidifier is now ready for Storage.
6. Store in a cool, dry location.
Note:It is recommended to clean the unit again before use.
Automatic Refill Program
Select the shipment interval and Vornado will
send replacement Filters automatically. Eliminate the hassle of remembering to reorder.
Maintain the high efficiency of your Vornado
Humidifier.
To sign up, visit www.vornado.com, email
consumerservice@vornado.com or call
1-800-234-0604. Cancel at anytime.
Part # MD1-0002
Problem Possible Cause and Solution
Unit fails to power on.
Unit makes a bubbling or
gurgling sound.
Unit is not producing
desired amount of
humidity.
Filters are in need of replacement too often.
Unit is not plugged in. Plug power cord into electrical outlet.
Household circuit breaker / ground fault interrupter has tripped or blown a fuse. Reset circuit breaker /
ground fault interrupter, or replace fuse. For assistance, contact a licensed electrician.
The unit has blown a fuse. Cease usage and unplug. Contact Consumer Service for assistance.
Unit is damaged or in need of repair. Cease usage and unplug. Contact Consumer Service for assistance.
This is normal. Water is being dispensed into Base.
Water level in Tank is empty or too low. Refill with clean, cool tap water. (See FILLING WATER TANK for
instructions.)
Unit has reached its set point. When set humidity level is reached, the Fan will turn off until humidity level in
the room drops below humidity set point.
Airflow is blocked. Remove obstruction.
Unit settings are too low. Set to High Fan Speed and Continuous Humidity for maximum humidity output.
The additional sodium in chemically softened water may cause Filters to harden or become mushy. Try using
untreated tap water or distilled water.
Try adding Bacteriostat or Water Treatment found at most hardware or home specialty stores to the water.
Or periodically remove the Filters and clean, by soaking them in cool tap water and two teaspoons of white
vinegar. Let stand 20 minutes, then rinse in cool water. Allow excess water to run off and dry before replacing
them in the Base. DO NOT wring.
Water is too hard. Use distilled water.