*931227-00*
6211/6211DS
931227-00
Electric Strike for Single Door Mortise or Cylindrical Application
Installation Instructions
Deadbolt will not function with this strike.
Check with factory for retrofit applications.
For lock or device preparation, see their directions.
Prepare frame for strike (see other side).
Wire strike (Figure 1). (Switches on 6211DS only.)
SOLENOID POWER REQUIREMENTS
Yellow solenoid wires: 12 VDC, 0.57 A
Black solenoid wires: 24 VDC, 0.29 A
(also shown on strike label)
DC
supply
AC
supply
Use crimp
connectors to
splice field wiring
to P1 leads
DC input is
{
nonpolarized
12 VAC SO-12 12 VDC
or
24 VAC SO-24 24 VDC
{
NOTE
P1 J1AP1A
12 VDC
or
24 VDC
P1
SO-12 or SO-24
J1
Solenoid
4. Install insert for auxiliary bolt operation (Figure 2).
5. Test strike: Apply solenoid power. Fail secure (FSE) lip u
Fail safe (FS) lip locks. Figure 1 shows status of switches.
6. Install strike with two #12-24 screws. Make sure clearance
between latch bolt and strike lip is 1/32” (Figure 3). If not,
uninstall strike, adjust (Figure 4), and reinstall.
7. If latch bolt does not extend far enough to actuate tripper,
install extension (Figure 5). (Tripper on 6211DS only.)
8. Test door: With strike unlocked, door opens with latch bolt
extended. When door closes, latch bolt rides over strike lip.
J2 P2
S1
S2
Fail safe (FS)J2Fail secure (FSE)
depressed, strike lip closed and locked
(switches and tripper on 6211DS only)
1
2
3
4
5
6
J2
Switches hown with tripper
Use crimp connectors to
splice field wiring to P2
leads; insulate unused leads
S1
S2
1
2
3
4
5
6
P2
Red (C)
Blue
Yellow
White (C)
Gray
Violet
SWITCH RATINGS
Standard: 5 A, 30 VDC
Gold: 0.25 A, 30 VDC
}
}
Figure 1
S1
(monitors
tripper)
S2
(monitors
strike lip)
hook on insert
into notch on
faceplate
Alternate insert
Figure 2
position
Latch bolt
Strike lip
1/32”
Top view;
faceplate not
shown for clarity
Figure 3
To adjust strike, loosen screws
A, B, and
backbox sideways as
necessary
A
For more
adjustment,
move
screw A
to hole D
C and move
D
B
C
Figure 4
NOTE:
Static Strength Rating 1500 lb.
Dynamic Strength Rating 70f
Endurance Rating 250,000 c.
Extension
Tripper
Figure 5

4-7/8”
4-1/8”
3/8”
LHR shown
RHR opposite
C lock and strike
L
5/8”
1-1/4”
1-15/32”
3/4”
3-3/8”
C strike
L
Suggested cutout
11/32” maximum
#16 drill and #12-24 tap 2 places
Reinforce for strike attachment as required
Frame Preparation for Strike
1-1/4”
2-7/16”
C lock and strike
L
5/8”
1-1/8”
2-1/16”
4-1/8”
2” minimum
clearance
Strike
backbox
assembly
3-3/8”
C strike
L
1-21/32” minimum clearance
1-11/16”
12”
clearance
1-1/4”
Strike Dimensions and Required Clearances
Customer Service
1-877-671-7011 www.allegion.com
1/8”
6”
© Allegion 2014
Printed in U.S.A.
931227-00 Rev. 01/14-c