Voltronic Power 1KVA, 2KVA Quick Manual

Quick Guide
LCD display (Please see the Operation section for the details of LCD display.
Power switch
1. Output receptacles (4xschuko,
4xuniversal, 6xNEMA, 4xIndia or 4x South Africa)
2. AC input
3. Circuit breaker
4. External battery connectors
5. Charge current selector: 10 A or 20
A
6. Operation mode selector: UPS or
Inverter
7. Solar panel terminal (option)
8. Solar charging indicator (option)
9. Charger fault indicator (option)
Inverter
1KVA/2KVA
1. Introduction
Thank you for purchasing the inverter. This simple solar inverter is designed to power your
surge power such as vacuums, small freezers, or drills. If the inverter is equipped with solar
charger, it becomes solar inverter which can convert solar power to battery power and provide
continuous power to connected equipment during night time.
2. Product Overview
Front View
Back View
V. 1.6
3. Important Safety Warning (SAVE THESE INSTRUCTIONS)
Model
Typical Amp.
1 meter (one-way)
Dia-mm
1K/2K
59 A
AWG 8
5.9
MODEL
1K
2K
CAPACITY
1000VA/600 W
2000VA/1200 W
INPUT
Voltage
110/120 VAC or 220/230 VAC
Voltage Range
75-150 VAC or 140-300 VAC
OUTPUT
Voltage Regulation (Batt. Mode)
+/-10%
Transfer Time
Typical 4-8 ms, 13ms max. (For PC)
40 ms max. (For Home Appliances)
Waveform
Pure Sine Wave
BATTERY
Battery Voltage
12 VDC
24 VDC
Floating Charge Voltage
13.5 VDC ± 0.5 VDC
27 VDC ± 1 VDC
Maximum AC Charge Current
10 A or 20 A (selectable)
SOLAR CHARGER (option)
Charging Current
50 A max.
Maximum PV Array Open Circuit Voltage
40 VDC
60 VDC
PHYSICAL
Dimension (DxWxH) mm
395 x 145 x 220
Net Weight (kgs)
10.1
14.8
Conventions used: WARNING! Warnings identify conditions or practices that could result in personal injury; CAUTION! Caution identify conditions or practices that could result in damaged to the
unit or other equipment connected.
Before using the inverter, please read all instructions and cautionary markings
on the unit, this manual and the batteries.
General Precaution-
Install the UPS in a protected area that is free of excessive dust and has adequate air flow.
Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT
operate the UPS where the temperature and humidity is outside the specific limits. (Please
check the specs for the limitations.)
CAUTION! The unit is designed for indoor use. Do not expose this unit to rain, snow or
liquids of any type.
CAUTION! To reduce risk of injury, only use qualified batteries from qualified distributors or
manufacturers. Any unqualified batteries may cause damage and injury. Do NOT use old or
overdue batteries. Please check the battery type and date code before installation to avoid
damage and injury.
WARNING! It's very important for system safety and efficient operation to use appropriate
external battery cable. To reduce risk of injury, external battery cables should be UL certified
and rated for 75°C or higher. And do not use copper cables less than 10AWG. Below is the
external battery cable reference according to system requirements.
Table 1 Minimum Recommended Battery Cable Size versus Length
CAUTION! If a remote or automatic generator start system is used, disable the automatic
starting circuit or disconnect the generator to prevent accident during servicing.
4. Specifications
CAUTION! Do not disassemble the inverter. Contact with the qualified service center when
service or repair is required. WARNING! Provide ventilation to outdoors from the battery compartment. The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment. CAUTION! Use insulated tools to reduce the chance of short-circuit when installing or working with the inverter, the batteries, or other equipments attached to this unit. CAUTION! For battery installation and maintenance, read the battery manufacturer's installation and maintenance instructions prior to operating.
Personnel Precaution -
CAUTION! Careful to reduce the risk or dropping a metal tool on the batteries. It could spark
or short circuit the batteries and could cause an explosion. CAUTION! Remove personal metal items such as rings, bracelets, necklaces, and watches when working with batteries. Batteries can produce a short circuit current high enough to make metal melt, and could cause severe burns.
CAUTION! Avoid touching eyes while working near batteries. CAUTION! Have plenty of fresh water and soap nearby in case battery acid contacts skin,
clothing, or eyes.
CAUTION! NEVER smoke or allow a spark or flame in vicinity of a battery.
5. Installation
NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is
damaged.
Connect to Utility and Charge
Plug in the AC input cord to the wall outlet. The unit will automatically charge the connected external battery even though the unit is off.
Connect External Battery
Step 1 - Install a DC Breaker in a positive battery line. The rating of the DC Breaker must be according to the inverter's battery current (50 Amp). Keep the DC breaker off. (see Fig. 1) Step 2- Connect battery cables to the terminals of battery. WARNING! Please use the appropriate battery cable. Please refer to Important Safety Warnings Section for the details.
1) Single battery connection (Refer to Fig. 1): When using a single battery, its voltage must be equal to the Nominal DC Voltage of the unit (see below Table 1).