User Manual
Thank you for purchasing our product.
Please read this manual carefully before use.
Please keep this manual properly after reading.
Safety Instructions
Please read the following precautions carefully.
Caution There may be a risk of death or serious injury.
Caution There may be a risk of personal injury or property
loss.
u Do not input signals exceeds the measurement range of this
product. Please select the correct test position and range to
avoid damage to the instrument or personal injury. “ ” will be
shown on the display when out of range.
u When the voltage to be measured exceeds 36V DC or 25V AC,
the operator shall be careful to avoid electric shock.
u Check the function position before measuring.
u Disconnect the test leads from the circuit before changing the
mode.
u For your safety, please read this manual carefully before use.
Please fully understand the instructions and use this product
correctly.
Caution
Do not measure circuits that exceed the maximum input rated value
1000V.
Measurement Notices
Common Notice
u DC/AC high voltage circuits are very dangerous, please be
careful to measure.
u Do not to add AC/DC voltages that exceeds the maximum
rated value between the ground terminal and test terminal.
u Do not add voltage that exceeds the allowable value.
u Do not operate this product with wet hands to avoid the risk
of electric shock.
u Do not use the product around explosive gas, vapor, or in
damp or wet environments.
u Do NOT touch the input terminals when measuring.
u Do not use test leads with damaged coatings.
Caution
AC/DC Voltage Measurement Notice
Caution
u The measured voltage should not exceed the rated maximum
test value, otherwise it may damage the product and endanger
personal safety.
u Do not measure voltages that exceed the allowable value.
AC/DC Current Measurement Notice
Caution
u The measured current should not exceed the rated maximum
test value, otherwise it may damage the product and
endanger personal safety.
u Use the 10A Terminal and the Mode to judge range and
choose the right function position when measure an
unknown current.
u It is strictly forbidden to input voltage in this measuring state.
Resistance Measurement Notice
u Before measuring the resistance, please make sure that all
capacitors in the circuit to be measured are fully discharged.
u It is strictly forbidden to input voltage in this measuring state.
Continuity Measurement Notice
u Please do not measure the continuity with a voltage circuit or
wire.
u It is strictly forbidden to input voltage in this measuring state.
Caution
Caution
Other Notices
Battery Change Notice
u Please turn off the power.
u Install the battery cover and tighten the screws before
measuring.
Test Leads Notice
Do not touch the pins of the test leads during the measurement.
Do not use test leads with damaged coatings.
Please do not stretch the cables to avoid breaking the test lead.
Dust and water are not supported.
Caution
Caution
Maintenance and Modification
Caution
Except for our company or our authorized individuals, please
do not attempt to repair or modify the circuit board to avoid
the danger caused by improper operation.
1. Introduction
This product is a multi-functional, auto-ranging digital
multimeter with a 6000 counts LCD display.
u Measurement functions include AC/DC voltage, AC/DC
current, resistance, diode test/continuity, NCV,
frequency/duty cycle, capacitance.
u Support True- RMS
u Support Auto Power Off
u Support temperature measurement
u Support data hold
2. General Specifications
※ Specifications are subject to change without notice.
※ Batteries included are samples.
※ Battery life may be shorter than regular commercial batteries.
If the backlight and buzzer are used frequently, battery life will
be shortened.
3. Electrical Specifications
4. Preparations for Measurement
4.1 Preparations
(1) Please check the product carefully before use and confirm if
there is cracks or missing items. If you have any questions,
please contact the store you purchased.
(2) Disconnect the test leads from the circuit before changing
the mode.
(3) Please note that if there are noise-generating devices
around, or large temperature difference, the data may
become unstable or there may be increasing errors.
(4) Please note that when measuring resistance, continuity,
current flows through the measured circuit will result in
incorrect measurement.
(5) When using this device, it may cause display differences
due to external strong noise, etc. If the measurement is not
available, please turn off the power and wait for a while,
then turn the power on again.
Note:
The display changes irregularly under the situations where
the test leads are not connected . This is caused by high
input sensitivity, not a fault.
When connected to the circuit, the correct measurement
can be taken after the data become stable.
Auto
DC Voltage
AC Voltage
(Frequency
Duty Cycle)
Temperature
DC Current
AC Current
Resistance
Ω
Continuity
Diode
Capacitance
Frequency
Duty Cycle
Hz/%
NCV Function
Data Hold/REL
HOLD/REL
Please rotate dial to AUTO position;
Put probes correctly to recognize
Voltage/Resistance/Continuity automatically.
Only when the voltage is higher than 0.8V, this data
will be shown on the display.
※ Voltage/Resistance/Continuity can be also
measured by switch dial to function position
manually.
1.Connect the black test lead to the COM Terminal and
connect the red test lead to Terminal;
2. Rotate dial to Mode or Mode;
3. Press SEL/NCV to toggle between AC/DC;
4. Touch the correct test points of the circuit to measure
the voltage;
5. Read the measured data on the display.
※ If reverse the test lead, it shows “ - ” mark.
The frequency is 40-1000Hz in AC Voltage Mode.
There is no special link between the measured value
and the test leads.
1.Connect the black test lead to the COM Terminal and
connect the red test lead to the Terminal or the
10ATerminal (based on the value of current) ;
2.Rotate dial to Mode or Mode;
3.Press SEL/NCV to toggle between AC/DC mode;
4.Cut off the circuit path to be measured. Then connect the
test leads across the circuit and power supply;
5.Read the measured current on the display.
※Please measure current by 10A terminal within 15 sec
When measuring DC current, please access to the circuit.
from the red test lead to the black test lead based on the
direction of the current flow.
1.Press SEL/NCV to toggle between AC/DC mode
2.Please turn off the power of this component to be tested.
3.All capacitors are fully discharged.
※ There is no special link between the measured value
and the test leads.
The built-in beeper will beep when the resistance is lower
than 50Ω, which indicates a short circuit.
※Please measure the resistance range in order to get
detailed resistance.
1.Connect the red probe to the anode and the black probe
to the cathode of the diode being tested;
2.Read the forward bias value on the display;
3.If the polarity of the test leads is reversed with diode
polarity or the diode is broken and it shows “ - ” mark.
a. Do not input voltage at the Diode Mode.
b. Disconnect circuit power and discharge all capacitors
before you test diode.
1. Connect the red test lead to the anode and the black
test lead to the cathode of the capacitor to be tested;
※ Disconnect circuit power and discharge all capacitors
before testing capacitance.
The electrostatic capacity becomes larger, the
measurement time is longer.
1. Press SEL/NCV to toggle data
2. A higher frequency may be measured in this mode, .
※The maximum frequency that can be measured is 9.999Mhz.
The Frequency Mode only applies to measure high frequency with low voltage.
1.Keep pushing the NCV button to enter the NCV mode.
2.Hold the product and move it around, the built-in beeper will beep when the inner sensor
detects AC voltage nearby. The stronger the voltage is, the quicker the beeper beeps.
※ It is impossible to use NCV function in current mode.
1.Press the Data Hold / REL function button in each measurement mode.
2.The product will keep the present reading on the display by short press.
※The product allows relative measurements for Voltage, Current, and Capacitance;
Hold down this button for a few seconds to enter the REL mode;
Press again to exit this mode.
5. Appearance
⑦
①
⑧
②
③
Back
Auto-recognition for Voltage
/Resistance/ Continuity by
connecting test leads
7.Maintenance
7.1 Replace Battery
When “ ” is shown on the display, batteries should be replaced as
below:
1. Remove the test leads and turn off the product before replacing
the batteries;
1. Loosen the screw on the battery door and remove the battery door.
2. Replace the used batteries with new batteries of the same type.
3. Place the battery door back and fasten the screws.
⑥
①LCD Display
②SEL/NCV
③Function Dial
④Voltage/Diode/Resistance/
Continuity/Frequency/Temperature
/Capacitance Input Terminal
⑤COM Terminal
⑥Current Input Terminal
⑦Data Hold/REL
⑧Stand
⑨Battery Cover
⑩Probe Cover
⑪ Test Lead Insulator
⑫ Test Leads
6. Measurements
6.1 Steps for measurement
1. Confirm the measurement content in the table on the right.
2. Switch function dial according to the item to be measured.
3. Please remove test leads after measuring.
4. Turn off the power.
1. Do not confuse the item to be measured with the
position of the function.
2. Do not exceed the maximum rated value of each function.
3. Do not switch functions or modes during measurement.
4. During the measurement process, hold the insulated part
of the test lead and do not hold the pins of the test lead.
⑩
⑤
④
Caution
⑨
⑫
⑪
Function Dial
(a)Power (OFF)
(b)AUTO (Voltage/Resistance/
Continuity)
(c)Voltage/Frequency/
Duty Cycle
(d)Temperature/mV Voltage
(e)Diode/Resistance/Continuity/
Capacitance
(f) Frequency/Duty Cycle
(g)A Current
(h)mA Current
6.2 Auto Power Off
1. This feature prevents the battery from running out if you forget
to turn off the power.
2. If the operation is not continued for about 15 minutes, the auto
power off function will automatically cut off the power.
3. If you want to cancel this function, you should press and hold
the SEL/NCV button and then turn it on again. It will be
cancelled after five beeps.
※Methods of Connecting Test Leads
① Put the black lead into COM terminal and put the red lead to
terminal in Picture1
② Put the red lead to 10A terminal when test the current in Picture2.
Picture1 Picture2
Red Test Leads
Black Test Leads
DC→AC→Hz→%
Please select temperature
function in mV by SEL/NCV
SEL键切换功能
Ω→ → →
Red Probe
Black Probe
Battery Box
Low Battery Indicator
Stand
Battery Cover
Screw Hole
7.2 Replace the Fuses
If current measurement is not possible, make sure that the fuse
is not blown.
If it is blown, please replace the required rated fuse.
1. Remove the battery cover and battery according to the battery
replacement method;
2. Use a screwdriver to remove the two screws on the back cover.
3. Remove the back cover;
4. Replace the fuse;
5. Put the back cover and battery cover back, tighten the screws.
Back Cover
Screw Holes
Fuse
F2 600mA/250V
F1 10A/250V
7.3 Clean the Product
Wipe the product with a damp cloth and mild detergent.
Do not use abrasives or solvents. Dirt or moisture in the terminals
can affect readings.
*Remove the input signals before you clean the product.
7.4 Calibration
Calibration is regularly performed at the calibration laboratory to
ensure accurate measurements.
The recommended calibration period is once a year.
Please consult your dealer for calibration cost and delivery time.
8.Storage Method
Please turn off the power after use to avoid consuming the
built-in battery.
If it is not used for a long time, please remove the battery and
keep it.